ABB M3JP Series (Shanghai) High-Efficiency Flameproof Three-Phase Induction Motors for Hazardous Areas
ال ABB M3JP series are low-voltage cast-iron high-performance flameproof three-phase induction motors for hazardous areas manufactured by ABB Shanghai Electric Motors Co., المحدودة. Developed on ABB’s global unified design platform with advanced modular ADEPT design, they represent ABB’s flagship flameproof low-voltage motor range.
Designed specifically for explosive gas atmospheres in Zone 1 and Zone 2, these motors feature ultra-high efficiency (IE3 as standard, IE4 available for selected models) and exceptional reliability, widely used in petrochemical, coal, pharmaceutical, metallurgical and other industries.
- Model Naming Convention
| Part | معنى | مثال |
| M3JP | Series identification: High-efficiency flameproof three-phase induction motor for hazardous areas | M3JP |
| Frame Size | Center height (مم) and frame length | 80MA, 90LA, 100LA, 112MA, 132سم, 160MA, 180LA, 200LA, 225سم, 250م, 280س, 315س, 315م, 355س, 355م |
| تصاعد | International standard mounting configurations | M=B3 (foot-mounted) |
| A=B5 (flange-mounted) | ||
| B=B35 (foot + flange-mounted) | ||
| E=B14 (small flange-mounted) | ||
| البولنديين | Number of poles, determining synchronous speed | 2=2900rpm (50هرتز) |
| 4=1450rpm (50هرتز) | ||
| 6=970rpm (50هرتز) | ||
| 8=730rpm (50هرتز) | ||
| Special Options | Special designations | G=Special voltage/frequency |
| L=Low noise | ||
| W=Outdoor type | ||
| TH=Humid tropical type | ||
| CT4=Gas group IIC |
Complete model example: M3JP160MA4-CT4
وصف: M3JP series, 160mm frame, B5 flange mounting, 4 أقطاب (1450دورة في الدقيقة), gas group IIC, temperature class T4 flameproof motor.
- Key Technical Specifications
| غرض | معيار | خياري |
| Efficiency Class | IE3 (كفاءة عالية) | IE4 (Premium Efficiency) |
| Flameproof Rating | Ex db IIB T4 Gb (معيار) | Ex db IIC T4/T5/T6 Gb |
| Ex db I Mb (for coal mines) | ||
| Ingress Protection | IP55 | IP56 / IP65 (enhanced dust & water protection) |
| فئة العزل | Class F (temperature rise evaluated as Class B) | Class H |
| طريقة التبريد | IC411 (self-ventilated) | IC416 (separately driven fan cooling, suitable for VFD operation) |
| الجهد المقنن | 380V / 400V (50هرتز) | 220V/380V, 415V, 440V, 660V, إلخ. |
| التردد المقدر | 50هرتز | 60هرتز |
| نطاق الطاقة | 0.25kW ~ 950kW | Custom power |
| Pole Range | 2ص, 4ص, 6ص, 8ص | 10ص, 12ص (custom) |
| اتصال | Star/Delta (Star ≤3kW, Delta ≥4kW) | Special connection |
| Mounting Dimensions | IEC standard | Custom dimensions |
| Weight Range | تقريبا. 10كجم (smallest) ~ 1500kg (largest) | Depending on configuration |
- Flameproof Characteristics & الشهادات
4.1 Flameproof Principle
Featuring Ex db flameproof construction, safety is ensured by two protective measures:
Flameproof enclosure (Ex d): Withstands internal explosion pressure and prevents flame propagation to the external hazardous atmosphere.
Surface temperature limitation (Ex b): Maximum surface temperature of all motor parts does not exceed the limit defined by temperature class (T4=135°C, T5=100°C, T6=85°C).
4.2 Applicable Hazardous Environments
| بيئة | Applicable Zone | Gas Group | Temperature Class |
| Explosive gas atmosphere | Zone 1 (explosive mixture likely under normal operation) | IIB (معيار) | T4 (معيار) |
| Zone 2 (explosive mixture unlikely under normal operation, only in fault conditions) | IIC (خياري, for more hazardous gases including H₂, acetylene) | T5/T6 (خياري) | |
| Underground coal mine | Category I (التعدين) | I (methane) | T1–T4 |
4.3 الشهادات
محلي: CQST (China Quality Supervision and Testing Center for Explosion-Proof Products)
دولي: IECEx, ATEX, أول, وكالة الفضاء الكندية, إلخ.
Classification Society: ABS, DNV, LR, إلخ. (خياري)
- قائمة النماذج الكاملة (Grouped by Frame Size)
5.1 Small Frames (80–132mm)
| إطار | البولنديين | نطاق الطاقة (كيلوواط) | Typical Models |
| 80MA | 2,4,6 | 0.25–0.75 | M3JP80MA2 (0.75كيلوواط,2ص) |
| M3JP80MA4 (0.55كيلوواط,4ص) | |||
| M3JP80MA6 (0.25كيلوواط,6ص) | |||
| 90LA | 2,4,6 | 1.1–1.5 | M3JP90LA2 (1.5كيلوواط,2ص) |
| M3JP90LA4 (1.1كيلوواط,4ص) | |||
| M3JP90LA6 (0.75كيلوواط,6ص) | |||
| 100LA | 2,4,6 | 2.2–3.0 | M3JP100LA2 (3.0كيلوواط,2ص) |
| M3JP100LA4 (2.2كيلوواط,4ص) | |||
| M3JP100LA6 (1.5كيلوواط,6ص) | |||
| 112MA | 2,4,6 | 4.0–5.5 | M3JP112MA2 (5.5كيلوواط,2ص) |
| M3JP112MA4 (4.0كيلوواط,4ص) | |||
| M3JP112MA6 (3.0كيلوواط,6ص) | |||
| 132سم | 2,4,6,8 | 5.5–7.5 | M3JP132SM2 (7.5كيلوواط,2ص) |
| M3JP132SM4 (5.5كيلوواط,4ص) | |||
| M3JP132SM6 (4.0كيلوواط,6ص) | |||
| M3JP132SM8 (3.0كيلوواط,8ص) |
5.2 Medium Frames (160–250mm)
| إطار | البولنديين | نطاق الطاقة (كيلوواط) | Typical Models |
| 160MA | 2,4,6,8 | 11–15 | M3JP160MA2 (15كيلوواط,2ص) |
| M3JP160MA4 (11كيلوواط,4ص) | |||
| M3JP160MA6 (7.5كيلوواط,6ص) | |||
| M3JP160MA8 (5.5كيلوواط,8ص) | |||
| 180LA | 2,4,6,8 | 18.5–22 | M3JP180LA2 (22كيلوواط,2ص) |
| M3JP180LA4 (18.5كيلوواط,4ص) | |||
| M3JP180LA6 (15كيلوواط,6ص) | |||
| M3JP180LA8 (11كيلوواط,8ص) | |||
| 200LA | 2,4,6,8 | 30–37 | M3JP200LA2 (37كيلوواط,2ص) |
| M3JP200LA4 (30كيلوواط,4ص) | |||
| M3JP200LA6 (18.5كيلوواط,6ص) | |||
| M3JP200LA8 (15كيلوواط,8ص) | |||
| 225سم | 2,4,6,8 | 45–55 | M3JP225SM2 (55كيلوواط,2ص) |
| M3JP225SM4 (45كيلوواط,4ص) | |||
| M3JP225SM6 (30كيلوواط,6ص) | |||
| M3JP225SM8 (22كيلوواط,8ص) | |||
| 250م | 2,4,6,8 | 75–90 | M3JP250M2 (90كيلوواط,2ص) |
| M3JP250M4 (75كيلوواط,4ص) | |||
| M3JP250M6 (45كيلوواط,6ص) | |||
| M3JP250M8 (37كيلوواط,8ص) |
5.3 Large Frames (280–355mm)
| إطار | البولنديين | نطاق الطاقة (كيلوواط) | Typical Models |
| 280س | 2,4,6,8 | 110–132 | M3JP280S2 (132كيلوواط,2ص) |
| M3JP280S4 (110كيلوواط,4ص) | |||
| M3JP280S6 (75كيلوواط,6ص) | |||
| M3JP280S8 (55كيلوواط,8ص) | |||
| 315س | 2,4,6,8 | 160–200 | M3JP315S2 (200كيلوواط,2ص) |
| M3JP315S4 (160كيلوواط,4ص) | |||
| M3JP315S6 (110كيلوواط,6ص) | |||
| M3JP315S8 (75كيلوواط,8ص) | |||
| 315م | 2,4,6,8 | 220–250 | M3JP315M2 (250كيلوواط,2ص) |
| M3JP315M4 (220كيلوواط,4ص) | |||
| M3JP315M6 (132كيلوواط,6ص) | |||
| M3JP315M8 (90كيلوواط,8ص) | |||
| 355س | 2,4,6,8 | 280–315 | M3JP355S2 (315كيلوواط,2ص) |
| M3JP355S4 (280كيلوواط,4ص) | |||
| M3JP355S6 (160كيلوواط,6ص) | |||
| M3JP355S8 (110كيلوواط,8ص) | |||
| 355م | 2,4,6,8 | 355–400 | M3JP355M2 (400كيلوواط,2ص) |
| M3JP355M4 (355كيلوواط,4ص) | |||
| M3JP355M6 (200كيلوواط,6ص) | |||
| M3JP355M8 (132كيلوواط,8ص) |
- Cross-Reference Order Codes with Major Global Brands
Below are equivalent order codes for ABB M3JP series flameproof motors against other leading brands, matched by power, أقطاب, flameproof rating and mounting:
| ABB M3JP Model | سيمنز | شنايدر | إيتون | البديل المحلي (Nanyang Explosion Proof) |
| M3JP90LA4-1.1kW | 1LG4090-4AA70-Ex | ATV212HD11N4-Ex | D2N090L4-Ex | YBX3-90L-4-1.1kW |
| M3JP132SM4-5.5kW | 1LG4132-4AA70-Ex | ATV212HD55N4-Ex | D2N132S4-Ex | YBX3-132S-4-5.5kW |
| M3JP160MA4-11kW | 1LG4160-4AA70-Ex | ATV212HD11N4-Ex | D2N160M4-Ex | YBX3-160M-4-11kW |
| M3JP180LA4-18.5kW | 1LG4180-4AA70-Ex | ATV212HD18N4-Ex | D2N180L4-Ex | YBX3-180L-4-18.5kW |
| M3JP200LA4-30kW | 1LG4200-4AA70-Ex | ATV212HD30N4-Ex | D2N200L4-Ex | YBX3-200L-4-30kW |
| M3JP225SM4-45kW | 1LG4225-4AA70-Ex | ATV212HD45N4-Ex | D2N225S4-Ex | YBX3-225S-4-45kW |
| M3JP250M4-75kW | 1LG4250-4AA70-Ex | ATV212HD75N4-Ex | D2N250M4-Ex | YBX3-250M-4-75kW |
| M3JP315S4-160kW | 1LG4315-4AA70-Ex | ATV212HD16N4-Ex | D2N315S4-Ex | YBX3-315S-4-160kW |
- إرشادات الاختيار & توصيات الاستبدال
- Flameproof rating matching: Select according to gas group (IIB/IIC) and temperature class (T4/T5/T6) of the hazardous area. IIC motors can replace IIB, but not vice versa.
- Efficiency selection: IE3 standard for general applications; IE4 premium efficiency for high energy-saving requirements.
- طريقة التبريد: IC416 with separate fan recommended for VFD applications to avoid overheating at low speeds.
- أبعاد التركيب: Strictly comply with IEC standard dimensions to ensure compatibility.
- Certification requirements: Confirm required certifications for critical applications (CQST for domestic projects, IECEx/ATEX for international projects).
- Replacement notes:
Ensure replacement power ≥ original and flameproof rating ≥ original.
Verify mechanical dimensions: ارتفاع رمح, قطر رمح, keyway size.
Confirm terminal box position and cable entry size match the original motor.
For special environments (marine, outdoor, humid tropical), select correspondingly configured models.
- Ordering & Packaging Information
Official order code: Same as model number, على سبيل المثال, M3JP160MA4, M3JP225SM4-CT4.
Standard packaging: Plywood case, single or multiple units per package.
Origin: ABB Shanghai Electric Motors Co., المحدودة. (عنوان: 88 Tianning Road, Minhang District, Shanghai)
Lead time: 2–4 weeks for standard models; 4–8 weeks for custom models.
مُكَمِّلات: Motor body, terminal box cover, foundation bolts, certificate of conformity, copy of explosion-proof certificate.
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية