Product Overview & شرح النموذج
ACS 310-01E-02A4-2 is a general-purpose inverter from the ABB ACS310 series with single-phase 230 V input and three-phase output. It is mainly designed for variable-torque applications such as fans and pumps, with IP20 protection and C3 EMC filter compatibility.
Model Code Breakdown (ABB ACS310 Naming Convention)
| Code | معنى | وصف |
| ACS 310 | Basic series | ACS310 = general-purpose inverter, optimized for fan & pump variable-torque loads |
| 01ه | Frame & enclosure | 01 = Frame R1; E = IP20, no built-in filter (external filter required) |
| 02A4 | Rated output & الجهد االكهربى | 02A = rated output current 2.4 أ (0.37 كيلوواط); 4 = voltage class (200–240 V) |
| 2 | Input phase | 2 = single-phase input (200–240 V), three-phase 200–240 V output |
- Core Technical Specifications
2.1 Electrical Data
| غرض | مواصفة |
| Input power | Single-phase 200–240 V AC, 50/60 هرتز, ±10% tolerance |
| Output | Three-phase 0–240 V AC, 0–500 Hz, 0.37 كيلوواط / 2.4 أ, 150% الزائد ل 60 ق |
| وضع التحكم | V/f control (flux vector optional), built-in PID and PFC (pump/fan control) |
| Digital I/O | 2 المدخلات الرقمية, 1 relay output (250 V AC/2 A, 30 V DC/2 A) |
| Analog I/O | 1 المدخلات التناظرية (0–10 V or 4–20 mA), 1 الإخراج التناظري (0–20 mA) |
| Communication | Built-in Modbus EIA-485, Modbus RTU supported |
| إي إم سي | Category C3 (industrial environment), external filter required |
2.2 Mechanical Characteristics
| غرض | مواصفة |
| Frame | R1 (132 × 175 × 155 مم, W × H × D) |
| Mounting | Wall or cabinet mounting, vertical installation; ≥100 mm clearance top & bottom |
| حماية | IP20 |
| درجة حرارة | Operating: -10 °C to +40 °C (derate above 40 °C); Storage: -40 °C to +70 °C |
| وزن | تقريبا. 1.5 كجم |
| Cooling | Natural convection (no fan) |
- Key Functions & Applications
3.1 Fan & Pump Special Functions
Built-in multi-pump control (up to 4 مضخات), alternation and automatic backup
Pipe cleaning and priming functions for system commissioning and maintenance
Sleep / wake-up function for significant energy saving
Anti-blockage and dry-run protection for pumps
Motor noise smoothing to reduce noise
3.2 التطبيقات النموذجية
| Application | Suitable Equipment | Key Benefits |
| HVAC systems | Centrifugal fans, مضخات, cooling tower fans | 30–50% energy saving, stable, low noise |
| Water treatment | Booster pumps, submersible pumps, sewage pumps | Dry-run protection, multi-pump control |
| Industrial circuits | Cooling pumps, lubrication pumps | Longer service life, lower maintenance |
| Small machinery | الناقلون, mixers, small compressors | Easy to use, cost-effective |
- Series Models & Alternatives
4.1 ACS310 Series (Frame R1, 200–240 V single-phase)
| نموذج | القوة المقدرة | التصنيف الحالي | Main Difference | Application |
| ACS310-01E-02أ4-2 | 0.37 كيلوواط | 2.4 أ | Basic model | Small fans, micro pumps |
| ACS310-01E-04A7-2 | 0.75 كيلوواط | 4.7 أ | Higher power | Small/medium fans & مضخات |
| ACS310-01E-07A5-2 | 1.5 كيلوواط | 7.5 أ | Higher power | Medium fans & مضخات |
| ACS310-01E-09A8-2 | 2.2 كيلوواط | 9.8 أ | Higher power | Large fans & مضخات |
4.2 Recommended Alternatives
| Alternative | Main Difference | Application |
| ACS310-03E-02A4-4 | Three-phase 380–480 V input, 0.37 كيلوواط | Industrial three-phase systems |
| ACS355-01E-02أ4-2 | Full-featured, built-in EMC filter | Higher EMC & functional requirements |
| ACS580-01-03A3-4 | Vector control, 180% الزائد | High dynamic & precision control |
- Accessories & Options
| ملحق | Type Code | وصف |
| Control panel | CDP312R | Basic control and parameter setting |
| Advanced panel | CDP312R-ETH | With Ethernet, المراقبة عن بعد |
| EMC filter | 3AFE68300909 | C3 EMC filter for industrial environment |
| Brake unit | ACS-BU-01 | For frequent start/stop and braking |
| I/O extension | 3AXD50000038762 | 4 من + 2 DO expansion |
| Comm module | 3AXD50000038763 | Profibus-DP interface |
- تثبيت & استكشاف الأخطاء وإصلاحها
6.1 Installation Notes
- Electrical installation
Input must be protected by a circuit breaker and fuse matching 2.4 أ
Output cable: shielded, الأعلى. 50 m to prevent motor overvoltage
Separate control wiring from power wiring by ≥100 mm
- Mechanical installation
Mount vertically with sufficient ventilation
Derate 1% per °C above 40 °C
Avoid high vibration, dust, moisture, corrosive gas
6.2 Fault Codes
| Code | وصف | السبب المحتمل | حل |
| F001 | Overcurrent | Short circuit, motor overload, wrong settings | Check wiring, تقليل الحمل, reset parameters |
| F002 | الجهد الزائد | High supply voltage, fast deceleration | Check supply, adjust deceleration time |
| F003 | انخفاض الجهد | الجهد المنخفض, phase loss | Check input power |
| F004 | Overtemperature | Poor ventilation, blocked heatsink | Improve cooling, clean heatsink |
| F005 | Motor overload | Excess load, stall | Reduce load, check motor |
| F006 | Earth fault | Output grounded, motor insulation fault | Check cable and motor |
- Selection & Application Advice
- By load type
Fan/pump variable-torque loads: ACS310 series recommended
Constant-torque loads (conveyors, mixers): ACS355 or ACS580
- By power
≥ 0.37 كيلوواط: ACS310-01E-02أ4-2
0.37–2.2 kW: ACS310-01E series
> 2.2 كيلوواط: ACS310-03E three-phase series
- Energy-saving analysis
Fans and pumps can save 30–50% energy with VFD control
Use ABB DriveSize for accurate selection and energy calculation
As an entry-level model of the ABB ACS310 series, the ACS 310-01E-02A4-2 features compact design, easy operation, and fan/pump‑optimized functions, making it an ideal choice for small industrial and commercial applications. For advanced control or higher performance, upgrade to ACS355 or ACS580 series.
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية