Complete Technical Parameters of Siemens 3WL1116/3WL1216 1600A ETU45B-G-LCD-3P
The parameters cover dimensions including basic electrical characteristics, كسر القدرة, trip unit, mechanical & environmental performance, communication and installation, facilitating engineering selection and system matching.
- المعلمات الكهربائية الأساسية
| Parameter Item | Specification Value | ملاحظات |
| سلسلة المنتجات | Siemens SENTRON 3WL | قواطع دوائر الهواء (ايه سي بي) |
| Frame Size | 3WL1116 (Frame I) / 3WL1216 (Frame II) | 3WL1116: Standard breaking capacity; 3WL1216: High breaking capacity |
| التصنيف الحالي (في) | 1600أ | Frame size current 1600A, setting range 0.4–1In |
| رقم القطب | 3ص | Three-pole, 3-phase main circuit |
| تصنيف الجهد التشغيلي (إي) | 690الخامس و | 50/60هرتز, متوافق مع IEC 60947-2 |
| تصنيف الجهد العزل (واجهة المستخدم) | 1000الخامس و | Benchmark value for insulation withstand capability |
| Rated Impulse Withstand Voltage (Uimp) | 12كيلو فولت | Compliant with IEC 60947-1 |
| تصنيف وقت قصير الصمود الحالي (اي سي دبليو) | Frame I: 66كا / 1 ثانية; Frame II: 80كا / 1 ثانية | Ensures short-time thermal stability at 500V |
| كسر القدرة (وحدة العناية المركزة) | Frame I: 55/66ال; Frame II: 80/100ال | Ultimate breaking capacity at 500V; Frame II offers higher breaking capacity |
- Parameters of ETU45B-G-LCD Electronic Trip Unit
| Function Module | Specification Value | وصف |
| نوع الحماية | إل إس آي جي (ل: Overload/Long-time Delay; س: Short-circuit/Short-time Delay; أنا: ماس كهربائى لحظية; ز: Ground Fault) | Complete power distribution protection configuration |
| حماية الزائد (ل) | Characteristic Curve: I²t/I⁴t selectable; نطاق الإعداد: 0.4–1In | I⁴t characteristic improves selectivity with downstream devices |
| Short-time Delay Short-circuit Protection (س) | Setting Current: 2–10In; Time Delay: 0.1–0.4s | Adjustable inverse/definite time delay to prevent selective tripping |
| Instantaneous Short-circuit Protection (أنا) | Setting Current: 2–10In | Rapid short-circuit current interruption without time delay |
| Ground Fault Protection (ز) | Setting Current: 0.2–0.8In; Time Delay: 0.1–2s | Detects ground faults to avoid equipment damage |
| Display & Operation | LCD screen, rotary coding switch | Real-time display of current, trip cause and fault records |
| Reset Method | Manual/Auto selectable | Quick power supply recovery after fault clearance |
ثالثا. ميكانيكية & Environmental Parameters
| Parameter Item | Specification Value | ملاحظات |
| الحياة الميكانيكية | 150,000 العمليات | No-load operation, متوافق مع IEC 60947-2 |
| الحياة الكهربائية | 10,000 العمليات (ايه سي-3, في التصنيف الحالي) | On-load breaking life, related to operating frequency |
| آلية التشغيل | Spring-loaded energy storage type (manual/electric optional) | Electric mechanism suitable for remote control |
| جهات الاتصال المساعدة | معيار: 2NO+2NC, expandable to 4NO+4NC | Status feedback and control circuit interlocking |
| درجة الحرارة المحيطة | -25℃~+70℃ (operating); -40℃~+85℃ (storage) | Wide temperature range for industrial applications |
| فئة الحماية | IP30 (body); IP40 (with protective cover) | Prevents solid foreign object intrusion |
| ارتفاع | ≤2000m (derating required above 2000m) | Rated current derating by 1% for every 100m altitude increase |
| طريقة التركيب | Fixed type/Drawout type | Drawout type enables maintenance without power outage |
- Communication & Measurement Parameters
| وظيفة | مواصفة | Interface/Protocol |
| وحدة الاتصالات | COM15 (PROFIBUS DP) / كوم16 (MODBUS RTU) | خياري, supports data upload to monitoring system |
| Measurement Accuracy | Current: ±1%; Voltage: ±1.5%; قوة: ±2% | Compatible with Plus measurement function for energy management |
| Data Logging | 100 fault records (trip type, time, current value) | Fault tracing and system diagnosis |
| التحكم عن بعد | Supports remote opening/closing and parameter setting | Realized by electric mechanism + communication module |
- تثبيت & Dimension Parameters
| نوع التركيب | عرض (دبليو) | Height (ح) | Depth (د) | وزن |
| 3WL1116 Fixed Type | 320مم | 434مم | 291مم | تقريبا. 45كجم |
| 3WL1116 Drawout Type | 320مم | 434مم | تقريبا. 450مم | تقريبا. 55كجم |
| 3WL1216 Fixed Type | 460مم | 434مم | 291مم | تقريبا. 56كجم |
| 3WL1216 Drawout Type | 460مم | 434مم | تقريبا. 450مم | تقريبا. 65كجم |
| Mounting Mode | 35mm DIN rail/screw mounting | Frame I width: 320مم; Frame II width: 460مم; Unified height: 434مم |
- Key Selection & Application Tips
- Breaking Capacity Matching: Select frame size based on the system’s maximum short-circuit current. Frame I is suitable for scenarios ≤66kA, while Frame II is for ≤100kA. أ 20% margin is recommended.
- Trip Unit Setting: Enable LSIG protection for motor loads, with the ground fault setting recommended at 0.3–0.5In. LSI protection is sufficient for power distribution loads.
- Communication Compatibility: Select COM15/COM16 module for remote monitoring, ensuring protocol compatibility with PLC/SCADA systems (PROFIBUS/MODBUS).
- Installation Space: The drawout type occupies approximately 160mm more depth than the fixed type. Reserve sufficient operation and maintenance space during cabinet design.
- Replacement & Upgrade: The 3WL series has been upgraded to the 3WA series (على سبيل المثال, 3WA1116-3EG45-4GA4), featuring compatible dimensions and protection functions, plus added Ethernet communication and intelligent diagnosis.
—
سابعا. Compliance & شهادة
Compliant Standards: GB 14048.2, اللجنة الانتخابية المستقلة 60947-2, في 60947-2
الشهادات: م, أول, وكالة الفضاء الكندية (for some models), meeting compliance requirements for global industrial applications
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية