Core Description

This is a safety monitoring relay from the Allen-Bradley (روكويل أتمتة) سلسلة Guardmaster Minotaur MSR5T, نسخة السلسلة C. It is intended for low-risk safety applications in industrial automation systems, such as safety gate monitoring and emergency stop button control.

1 Complete Model Breakdown

الجزء النموذجيالتنسيق القياسيوصف
440ر440رProduct family identifier for Rockwell Automation Bulletin 440R safety relays, part of the Guardmaster safety product range
بSubseries code, representing the MSR5T Series (Minotaur Safety Relay Type 5T monitoring safety relay)
2302023020Function and configuration code, detailed as follows:
– 2: Supply type (universal 24V AC/DC power supply)
– 3: Number of safety outputs (3 normally open NO safety outputs)
– 0: Auxiliary output type (1 normally closed NC auxiliary output)
– 2: Input configuration (1 normally closed NC single‑channel input, for safety gate interlocks and E‑stop buttons)
– 0: Reset type (selectable automatic / manual reset via jumper)
جSeries version code, indicating Series C, the latest production version with firmware updates and performance improvements

2 Detailed Explanation of Each Code

  1. 440R – Product Family Identifier

440: Standard prefix for Rockwell Automation safety products, dedicated to the Guardmaster safety relay line

ر: Abbreviation for Relay, defining the product as a safety relay, distinguishing it from other 440-series devices such as safety switches (440ز) and safety controllers (440ج)

  1. B – Subseries Code (MSR5T)

B Corresponds exclusively to the Minotaur MSR5T model, a monitoring safety relay with key features:

Single-or dual-channel input (this model uses 1NC single-channel input)

3 independent redundant normally open safety outputs to ensure reliable safety function

1 normally closed auxiliary output for status feedback signals

Supports output monitoring to detect faults in the safety output circuit

  1. 23020 – Detailed Function Configuration Code
DigitمعنىValue in This Modelمواصفة
1st digit (2)Supply type2Universal 24V AC/DC power supply, wide‑range design for various control systems
2nd digit (3)Number of safety outputs33 مفتوحة عادة (لا) safety outputs for direct control of contactors or actuators
3rd digit (0)Auxiliary output type01 مغلقة عادة (نورث كارولاينا) auxiliary output for PLC status feedback or indicator control
4th digit (2)Input configuration21 مغلقة عادة (نورث كارولاينا) single‑channel input for low‑risk applications
5th digit (0)Reset type0Selectable automatic / manual reset via jumper on terminals X1‑X2
  1. C – Series Version Code

C Indicates the product is Series C, the latest production version

Version differences:

Series A: Original version

Series B: Improved version with partial functional optimizations

Series C: Latest version with firmware updates, performance enhancements, and compatibility improvements

All series versions are fully functionally compatible and can be directly interchanged

3 المعلمات التقنية الرئيسية (for 440R-B23020/C)

المعلمةمواصفة
نوع المنتجMinotaur MSR5T safety monitoring relay
Safety Ratingفئة 4, PLe (ISO 13849‑1), SIL 3 (اللجنة الانتخابية المستقلة 61508), Stop Category 0
Input Configuration1 مغلقة عادة (نورث كارولاينا) single‑channel input, suitable for safety gate interlocks and emergency stop buttons
Output Configuration3 مفتوحة عادة (لا) safety outputs + 1 مغلقة عادة (نورث كارولاينا) auxiliary output
Supply Voltage24V AC/DC (universal power supply)
Reset MethodAutomatic / manual reset (selectable via jumper)
تصاعدتركيب السكك الحديدية DIN (في 60715 compliant), عرض 22.5 مم
درجة الحمايةIP20 (front)
درجة حرارة التشغيل-25 °C to +60 °C

4 Application Areas & Selection Guidelines

التطبيقات النموذجية

Safety gate monitoring (low-risk applications)

Emergency stop button control

Safety circuit monitoring for small machinery

نقاط الاختيار الرئيسية

Confirm input type: ensure single-channel 1NC input meets safety device connection requirements

Check output quantity: verify 3 NO safety outputs + 1 NC auxiliary output satisfy control circuit demands

Verify supply compatibility: confirm 24V AC/DC universal power matches system voltage

Version selection: Series C is the latest version and recommended for priority use

 