Delta inverters use the standard naming convention:

VFD-[Power Code][Series Code][Voltage Code][Special Function Code].

Some new models (such as the MS300 series) adopt a more detailed extended naming format.

The following provides a comprehensive explanation from four aspects: general structure, meaning of each part, typical series examples, and special function codes.

  1. General Model Structure (Example: VFD007E23A)
موضعشفرةمعنىExample Description
1–3VFDProduct IdentifierVariable Frequency Drive. All Delta inverters start with this.
4–67Rated Power CodeRepresents 0.75 كيلوواط (750 دبليو). Different codes correspond to different power ratings.
7هSeries CodeIndicates VFD‑E series (low‑power inverter with built‑in PLC).
8–923الجهد االكهربى & Phase Code“2” = 200–240 V, “3” = 3‑phase input.
10أSpecial Function CodeStandard version with built‑in EMI filter.
  1. Detailed Breakdown of Each Part

2.1 Power Code vs. القوة المقدرة (كيلوواط)

Power Codeالقوة المقدرةPower Codeالقوة المقدرةPower Codeالقوة المقدرة
20.2151.5757.5
40.4222.211011
70.75373.715015
101555.522022

ملحوظة: Some high‑power models use actual power directly, على سبيل المثال, VFD110B43A = 110 كيلوواط.

2.2 Series Code & سمات

Series CodeSeries NameKey Featuresالتطبيقات النموذجية
مVFD‑Mضوضاء منخفضة, حجم صغيرSmall machinery, packaging, conveyors
هVFD‑EBuilt‑in PLCAutomated production lines
بVFD‑BSensorless vector control, high torqueالمشجعين, مضخات, الضواغط, cranes
فVFD‑FFor fans & مضخات, built‑in PIDالتدفئة والتهوية وتكييف الهواء, cooling towers, water supply
MSMS300Compact high‑performance general‑purposeSmall automation, replaces VFD‑M
MHMH300High‑performance vector, servo‑gradePositioning, tension control, sync motors
CP2000VFD‑CP2000Sensorless vector, high overloadGeneral industrial machinery
EDVFD‑EDDedicated for elevatorsPassenger & freight elevators, escalators

2.3 الجهد االكهربى & Phase Code

شفرةInput PowerOutputApplication Region
211‑phase 200–240 V3‑phase 0–240 VHome/small equipment, Asia/NA
233‑phase 200–240 V3‑phase 0–240 VIndustrial, Asia/NA
433‑phase 380–460 V3‑phase 0–460 VIndustrial, global
533‑phase 525–600 V3‑phase 0–600 VHigh‑voltage industrial

2.4 Special Function Suffix Codes

LetterمعنىLetterمعنىLetterمعنى
أWith EMI filter, معياربWith braking unitنWithout EMC filter
سBuilt‑in STOحEnhanced heat dissipationصHigher protection
‑21Special version‑00Standard version‑EAEnergy‑saving for fans/pumps
  1. New Extended Format (Example: VFD1A5MS43ANSHA, MS300)
موضعشفرةمعنىوصف
1–3VFDInverter identifierStandard prefix
4–61A5Rated output current1.5 أ ( 0.75 كيلوواط)
7–8MSرمز السلسلةMS300 series
9–1043Voltage code460 V 3‑phase input
11أIP ratingIP20
12نEMC configurationWithout EMC filter
13سSafety functionBuilt‑in STO
14سCoolingStandard cooling
15–16AASpecial optionsStandard configuration
  1. Complete Model Examples

Example 1: VFD007E23A

VFD: Inverter

007: 0.75 كيلوواط

ه: E series (built‑in PLC)

23: 3‑phase 200–240 V input

أ: Standard with EMI filter

Example 2: VFD110B43A

VFD: Inverter

110: 110 كيلوواط

ب: B series (sensorless vector)

43: 3‑phase 380–460 V input

أ: Standard with EMI filter

Example 3: VFD1A5MS43ANSHA

VFD: Inverter

1A5: 1.5 A output ( 0.75 كيلوواط)

MS: MS300 series

43: 460 V 3‑phase input

أ: IP20

ن: No EMC filter

س: ستو

س: Standard cooling

AA: Standard version

  1. اختيار & Identification Tips
  2. Power matching: Select according to motor rated power; inverter ≥ 1.1× motor power recommended.
  3. Voltage compatibility: Confirm input phase and voltage (21/23/43, إلخ.).
  4. Series function: Choose by application (F for fans/pumps, E for PLC).
  5. متطلبات خاصة: Select protection, إي إم سي, and safety functions as needed.
  6. Backward compatibility: New models (على سبيل المثال, MS300) replace older ones.
  7. Quick Identification Mnemonic

Start with VFD,

Numbers show power,

Letters show series,

Two digits show voltage,

Suffix shows features.

With the above explanation, you can easily identify the power, مسلسل, الجهد االكهربى, and functions of any Delta inverter model for accurate selection, purchasing, and maintenance.