ويشات: +86-13184948252 واتس اب: 0086-13811255435 بريد إلكتروني: كينت@bestcontactor.com

عن اتصال |

ABB ESB20-20N-06 قواطع - المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية

قواطع/

ABB ESB20-20N-06 قواطع

ABB ESB20-20N-06 Technical Analysis Report This is a 2-pole, 20أ, 2لا, 230V AC/DC universal coil modular installation contactor, suitable for single-phase load control in residential and industrial environments. It features silent operation, low power consumption, and integrated overvoltage protection, with a width of only 18mm and standard 35mm DIN rail mounting. Order code: 1SBE121111R0620. نموذج ...

  • تفاصيل المنتج

ABB ESB20-20N-06 Technical Analysis Report

This is a 2-pole, 20أ, 2لا, 230V AC/DC universal coil modular installation قواطع, suitable for single-phase load control in residential and industrial environments. It features silent operation, low power consumption, and integrated overvoltage protection, with a width of only 18mm and standard 35mm DIN rail mounting. Order code: 1SBE121111R0620.

  1. Model Breakdown
الجزء النموذجيوصف
ESBProduct family: ABB ESB series building / installation contactors
20التصنيف الحالي: 20أ (AC-1 duty)
20Main contact configuration: 2 لا, 0 نورث كارولاينا
نFamily identifier: Standard ESB..N installation contactor (vs. EN..N with manual switch)
6رمز الجهد لفائف: 230V AC/DC universal
  1. المواصفات الأساسية

Electrical Data

غرضقيمةملحوظات
Rated operational current (ايه سي-1)20أحمل مقاوم
Rated operational power (AC-7a, 230V)4.6كيلوواطSingle-phase motor load
Rated operational current (ايه سي-3, 230V)Single-phase motor load
تصنيف الجهد العزل (واجهة المستخدم)400VIEC compliant
Rated impulse withstand voltage (امب)6كيلو فولتIEC compliant
Coil voltage230V AC/DCUniversal, no polarity required
Coil powerInrush: ~12VA/10WLow-power, energy-saving design
Sealed: ~2VA/2W
Control circuit frequency50/60هرتزUniversal range

ميكانيكية & Environmental Data

غرضقيمةملحوظات
Number of poles22 main circuits
تكوين الاتصال2لا + 0نورث كارولايناNo auxiliary contacts
Mechanical durability1,000,000 العملياتHigh endurance
Electrical durability (AC-7a/7b)150,000 العملياتاللجنة الانتخابية المستقلة 60947-4-1 compliant
Width18ممModular, space-saving
تصاعد35مم DIN السكك الحديديةStandard mounting
درجة حرارة التشغيل-25°C ~ +55°CWide temperature range
Storage temperature-40°C ~ +85°CHigh-reliability design
Protection degreeIP20Finger-safe, suitable for distribution boards
  1. وصف الوظيفة
  2. Universal coil technology: AC/DC universal coil, no AC/DC distinction, flexible installation, completely silent and vibration-free operation.
  3. Integrated overvoltage protection: Built-in overvoltage suppression in control circuit, improves system reliability and service life.
  4. تصميم وحدات: Only 18mm wide, fully compatible with other modular DIN rail components, saves cabinet space.
  5. توافق الملحقات: Supports standard accessories (اتصالات مساعدة, mechanical interlocks, إلخ.), tool-free plug-and-play installation.
  6. Safety design: Complies with EN/IEC/UL standards, provides reliable electrical isolation for personnel and equipment safety.
  7. Wide application: Suitable for controlling electric heaters, hot water systems, pump/fan motors, lighting and other single-phase loads.
  8. توصيات الاختيار

Suitable Applications

إضاءة, التدفئة, ventilation control in residential and commercial buildings

Single-phase motor control (مضخات, المشجعين) for small industrial equipment

Noise-sensitive environments (المستشفيات, offices, homes)

Space-limited distribution boards / control cabinets

Selection Criteria

  1. Load type matching:

حمل مقاوم (ايه سي-1): Use 20A rated current directly

Motor load (AC-7a/7b): Recommended ≤9A (4.6كيلوواط) at 230V single-phase

Inductive load: Derating or surge suppressor recommended

  1. Coil voltage selection:

Match control system supply (230V AC/DC)

Other voltages available: ESB20-20N-01 (24V), ESB20-20N-04 (110V)

  1. تكوين الاتصال:

This model: 2لا, suitable for two independent circuits

For NC contacts: ESB20-02N series (2نورث كارولاينا)

For auxiliary contacts: Add auxiliary contact modules

  1. Environmental conditions:

Derate above +40°C ambient temperature

Extra protection required in humid or corrosive environments

  1. Installation Notes

Pre-Installation

Verify model matches order, inspect for physical damage

Confirm coil voltage matches control supply

Prepare standard 35mm DIN rail and suitable terminals

Installation Procedure

Clip contactor firmly onto 35mm DIN rail

Wire main and control circuits per diagram; coil is non-polarized

Terminal torque: 2.5ن · م (conductor: 0.5–2.5mm²)

Accessories clip directly onto top/side without tools

أمان

Isolate and verify voltage-free before installation

Separate main and control wiring to avoid interference

Ensure adequate ventilation to prevent overheating

Maintain ≥5mm clearance around contactor for heat dissipation

التكليف & صيانة

Check wiring before first energization

Test contactor operation for correct switching and no abnormal noise

Inspect contacts and terminal tightness regularly (at least annually)

  1. نماذج بديلة

Same-Series Alternatives

نموذجاختلافطلب
ESB20-20N-0124V AC/DC coilLow-voltage control systems
ESB20-20N-04110V AC/DC coil110V control systems
ESB20-02N-062NC configurationApplications requiring normally closed contacts
EN20-20N-06With manual operatorEmergency manual control

Upgraded Alternatives

نموذجUpgradeطلب
ESB25-20N-0625تيار مقننHigher load requirements
ESB40-40N-064-القطب, 40أThree-phase or higher current
ABB AF seriesIndustrial contactorsHeavy-duty industrial environments

ABB ESB20-20N-06 is a compact, high-performance installation contactor. With silent operation, universal coil, low power consumption and modular design, it is an ideal solution for single-phase load control in residential and industrial applications. Proper selection, installation and maintenance ensure long-term reliable performance and safe, efficient control for electrical systems.

ABB Contactor Standard Selection Procedure

(Industrial & Building, for sales / quotation / design)

Using ESB (building) and AF/A (industrial) as examples – 8-step precise selection ready for proposals and quotations.

  1. Define Application & Product Family

Building / Residential / Distribution board: إضاءة, التدفئة, مضخات, المشجعين, small motors → ESB/EN series (silent, DIN rail, narrow width)

Industrial / Equipment / Control cabinet: المشجعين, مضخات, الضواغط, motor main circuits → AF/A series (wide voltage, long life, heavy-duty)

  1. Determine Load Category (Critical for Derating)

Per IEC 60947 utilization categories:

ايه سي-1: Resistive loads (heaters, إضاءة) → use rated current directly

ايه سي-3: Squirrel-cage motor DOL (most common industrial) → motor current ≤ contactor rated current

AC-7a/7b: Building small motors, المشجعين, pumps → use building contactor rated values

  1. Calculate Operating Current & القدرة المقدرة
  2. Determine current from power / الجهد االكهربى
  3. Allow 1.1–1.25x safety margin (inrush, continuous duty)
  4. Select corresponding rated current (Ie) from ABB catalog

مثال: 230V single-phase 2kW heater ≈ 8.7A → ESB20-20N is sufficient

  1. Select Number of Poles

1ص: مرحلة واحدة, single circuit

2ص: مرحلة واحدة, double-pole (L+N switching, building standard)

3ص: Three-phase motors / industrial (most common)

4ص: ثلاث مراحل + N or double-break

  1. Select Coil Voltage & يكتب
  2. Control voltage: 24V, 110V, 230V, 400V, إلخ.
  3. Coil type:

Building: AC/DC universal coil (ESB series, non-polar, silent)

Industrial: Wide-range coil (AF series, stable at 85–110% Un)

  1. Define Auxiliary Contact Requirements

Built-in: From model (20=2NO, 02=2NC)

Expandable: EH series auxiliary contacts (1NO+1NC, 2لا, إلخ.)

Used for: Status feedback, interlocking, sequential control

  1. Environmental & Special Requirements

ارتفاع >1000م, temperature >40°C → derate or upsize

Silent requirement (residential/office): Must use ESB silent type

حماية: IP20 normally sufficient for panel mounting

Mechanical interlock / reversing: Use dedicated interlock accessories

  1. Final Verification: نموذج + الشهادات
  2. Confirm full model: family–current–contacts–coil

مثال: ESB20-20N-06

  1. Verify certifications: سي سي سي, اللجنة الانتخابية المستقلة, RoHS
  2. Confirm mounting: 35مم DIN السكك الحديدية / screw mounting

Simplified Selection Mnemonic

  1. Choose family by application
  2. Choose duty by load type
  3. Calculate current with margin
  4. Confirm poles and coil voltage
  5. Add aux contacts for control
  6. Check environment and derate
  7. Verify model for final list