M1M: ABB M1M Series Motor Protection and Management Unit (Motor Protection Controller)
2TAZ664052R0007: Corresponding ABB original order number / material code
- نوع المنتج
Low-voltage three-phase motor integrated protection relay, used for motor protection, monitoring and basic control.
- الوظائف الأساسية
الزائد, locked-rotor, and underload protection
Phase sequence, خسارة المرحلة, and phase imbalance protection
Earth fault / earth leakage protection
Motor operating status monitoring and fault output
- نفس السلسلة & نماذج بديلة
Same series: Full ABB M1M series (M1M 01/02/03 and other current ratings)
Upgraded alternatives: ABB M102 / M2M series (functionally compatible with enhanced performance)
البدائل عبر العلامات التجارية: Siemens 3RB series, Schneider EOCR series motor protection relays
- التطبيقات النموذجية
Protection for three-phase asynchronous motors such as industrial fans, مضخات المياه, الناقلات, والضواغط, as well as automated production lines and factory low-voltage power distribution systems.
ABB M1M Series Digital Multifunction Power Meters
- معنى النموذج & تحديد موضع المنتج
Model Breakdown
M1M: ABB System pro M Series Digital Multifunction Power Meters (not motor protectors; please distinguish carefully)
Suffix numbers: Product function level (10/12/15/20/30); higher numbers indicate richer functions
Complete model example: M1M-2TAZ664052R0007 (2TAZ664052R0007 is the ABB original order number / material code)
تحديد موضع المنتج
ABB’s new-generation modular DIN-rail mounted multifunction power monitoring meters, used for energy metering, power quality analysis, and electrical parameter monitoring in mediumand low-voltage primary and secondary distribution systems. Supports Modbus communication and is suitable for industrial and building applications.
- Full Series Comparison
| نموذج | الوظائف الأساسية | Communication Interface | I/O | Supply Voltage | Sample Order No. |
| M1M 10 | Basic energy measurement, no display | لا أحد | لا أحد | No auxiliary power required | 2TAZ661010R2000 |
| M1M 12 | Basic energy measurement, LED indication | لا أحد | لا أحد | No auxiliary power required | 2TAZ661210R2000 |
| M1M 15 | Multifunction measurement, LCD display | Optional Modbus | لا أحد | 100–230V AC/DC | 2TAZ661510R2000 |
| M1M 20 | Multifunction measurement, LCD display | Optional Modbus | لا أحد | 100–230V AC/DC | 2TAZ662010R2000 |
| M1M 30 | Advanced measurement, power quality analysis | Optional Modbus/Ethernet | Optional 2DI/2DO | 100–230V AC/DC | 2TAZ663010R2000 |
| M1M 30 I/O | Advanced measurement + I/O control | مودبوس ار تي يو | 2DI/2DO | 100–230V AC/DC | 2TAZ663012R2001 |
| M1M 30 Ethernet | Advanced measurement + Ethernet | Modbus TCP/IP | لا أحد | 100–230V AC/DC | 2TAZ663011R2001 |
- المواصفات الفنية (M1M 30 مسلسل)
Measurement accuracy: Current/voltage class 0.2, active energy class 0.5S (متوافق مع IEC 62053-22), reactive energy class 2
Measured parameters: Three-phase voltage/current, active/reactive/apparent power, عامل الطاقة, تكرار, energy metering (forward/reverse), harmonic analysis (selected models)
CT input: Standard 1A/5A, supports star (3ه) or delta (2ه) اتصال
Ingress protection: IP51 (اللوحة الأمامية), IP20 (محطات)
تصاعد: 35مم DIN السكك الحديدية, 18عرض ملم (1 module)
- سيناريوهات التطبيق الأساسية
- Sub-metering in commercial buildings (إضاءة, التدفئة والتهوية وتكييف الهواء, power circuits)
- Power distribution system monitoring and energy efficiency analysis in industrial plants
- Power quality monitoring in data centers
- Real-time electrical parameter monitoring in low-voltage distribution cabinets
- Power generation metering for renewable energy systems (PV / طاقة الرياح)
- نماذج بديلة & Brand Comparison
Upgraded Alternatives (Same Brand)
Function expansion: ABB M2M series (higher accuracy, more communication protocols)
النسخة الأساسية: ABB M1M 10/12 (basic energy metering, تكلفة أقل)
البدائل عبر العلامات التجارية
| ماركة | Recommended Replacement | Compatibility Notes |
| شنايدر | PowerLogic PM5000 series | Similar functions, compatible communication protocols |
| سيمنز | SENTRON PAC series | Comparable measurement accuracy, supports Modbus |
| البدائل المحلية | Acrel PZ series, Chint DTSU series | Cost advantage, compatible basic functions |
- إرشادات الاختيار
- Measurement needs: Basic energy metering → M1M 10/12; real-time monitoring → M1M 15/20; power quality analysis → M1M 30
- Communication needs: Remote monitoring → models with Modbus (M1M 15/20/30)
- Control needs: Digital input/output required → M1M 30 I/O
- Installation environment: Ensure operating temperature range (-25°C to +55°C) and protection class requirements
Complete List of ABB Multifunction Power Meters
This list covers ABB’s mainstream multifunction power meter series, sorted from basic metering to advanced power quality analysis by product positioning. Includes model numbers, core functions, technical parameters, order numbers, and application scenarios for easy selection and procurement reference.
- M1M Series (System pro M, Modular DIN-Rail Mounted)
ABB’s new-generation compact multifunction power meters for mediumand low-voltage primary and secondary distribution systems. Only 18mm wide (1 module) and supports hot-swap.
I.1 Basic Metering Type (No Display / LED Indication)
| نموذج | الوظائف الأساسية | فئة الدقة | تواصل | I/O | مزود الطاقة | Sample Order No. | طلب |
| M1M 10 | Three‑phase energy measurement (no display) | Active 0.5S, Reactive 2 | لا أحد | لا أحد | No auxiliary power | 2TAZ661010R2000 | Basic energy statistics, low‑cost applications |
| M1M 12 | Three‑phase energy measurement (LED status indication) | Active 0.5S, Reactive 2 | لا أحد | لا أحد | No auxiliary power | 2TAZ661210R2000 | Simple circuit monitoring, fault indication |
I.2 Multifunction Display Type (شاشة LCD)
| نموذج | الوظائف الأساسية | فئة الدقة | تواصل | I/O | مزود الطاقة | Sample Order No. | طلب |
| M1M 15 | Three‑phase full‑electrical measurement, LCD display | Active 0.5S, Reactive 2 | Optional Modbus RTU | لا أحد | 100–230V AC/DC | 2TAZ661512R2000 | Sub‑metering in commercial buildings, industrial monitoring |
| 10239994 | |||||||
| M1M 15 I/O | Full‑electrical measurement + 2DI/2DO | Active 0.5S, Reactive 2 | مودبوس ار تي يو | 2DI/2DO | 100–230V AC/DC | 2TAZ661512R2001 | Local alarm/control, equipment interlock |
| M1M 20 | Full‑electrical + THD measurement, LCD display | Active 0.2S, Reactive 2 | Optional Modbus RTU | لا أحد | 100–230V AC/DC | 2TAZ662012R2000 | Industrial energy efficiency analysis, power quality monitoring |
| 10239996 | |||||||
| M1M 20 I/O | Full‑electrical + ثد + 2DI/2DO | Active 0.2S, Reactive 2 | مودبوس ار تي يو | 2DI/2DO | 100–230V AC/DC | 2TAZ662012R2001 | Local control, alarm output |
| M1M 20 Ethernet | Full‑electrical + ثد + Ethernet | Active 0.2S, Reactive 2 | Modbus TCP/IP | لا أحد | 100–230V AC/DC | 2TAZ662014R2000 | Network integration, المراقبة عن بعد |
I.3 Advanced Power Quality Type
| نموذج | الوظائف الأساسية | فئة الدقة | تواصل | I/O | مزود الطاقة | Sample Order No. | طلب |
| M1M 30 | Full‑electrical + harmonic analysis (up to 40th), data logging | Active 0.2S, Reactive 2 | Optional Modbus RTU | لا أحد | 100–230V AC/DC | 2TAZ663012R2000 | Power quality analysis, energy optimization |
| 10239997 | |||||||
| M1M 30 I/O | Full functions + 2DI/2DO | Active 0.2S, Reactive 2 | مودبوس ار تي يو | 2DI/2DO | 100–230V AC/DC | 2TAZ663012R2001 | Local control + إنذار, equipment interlock |
| M1M 30 Ethernet | Full functions + Ethernet | Active 0.2S, Reactive 2 | Modbus TCP/IP | لا أحد | 100–230V AC/DC | 2TAZ663014R2000 | Remote power quality monitoring, system integration |
| M1M 30 I/O Ethernet | Full functions + 2DI/2DO + Ethernet | Active 0.2S, Reactive 2 | Modbus RTU/TCP | 2DI/2DO | 100–230V AC/DC | 2TAZ663014R2001 | Smart power distribution systems, energy management |
Special model: M1M-2TAZ664052R0007 (custom version of M1M series, order no. 2TAZ664052R0007), functions equivalent to M1M 30, for specific project requirements.
- M2M Series (System pro M compact, Panel Mounted)
ABB mid-range power quality analyzers, 96ملم واسعة (4 الوحدات النمطية), suitable for mounting on distribution cabinet doors. Fully functional with advanced power quality analysis.
| نموذج | الوظائف الأساسية | فئة الدقة | تواصل | I/O | التحليل التوافقي | Data Logging | Sample Order No. | طلب |
| M2M 10 | Full‑electrical measurement, LCD display | Active 0.2S, Reactive 2 | مودبوس ار تي يو | 2DI/2DO | Up to 31st | Basic logging | 2CSG299883R4052 | Industrial power monitoring, energy efficiency analysis |
| M2M 20 | Power quality analysis, event recording | Active 0.1S, Reactive 2 | Modbus RTU/TCP | 4DI/4DO | Up to 40th | Advanced logging | 2CSG299884R4052 | Critical load monitoring, fault diagnosis |
| M2M 30 | Advanced power quality, PQDIF export | Active 0.05S, Reactive 2 | Modbus RTU/TCP | 8DI/8DO | Up to 63rd | Comprehensive logging | 2CSG299885R4052 | مراكز البيانات, critical production equipment |
| إيثرنت/IP |
ثالثا. M4M Series (Network Analyzers)
ABB high-end power quality analyzers, standalone installation, for mediumand high-voltage distribution systems, providing complete power quality analysis and energy management.
| نموذج | الوظائف الأساسية | فئة الدقة | تواصل | I/O | التحليل التوافقي | Data Logging | طلب |
| M4M 100 | Full parameter measurement, power quality analysis | Active 0.02S, Reactive 1 | Modbus RTU/TCP | 16DI/16DO | Up to 63rd | Large‑capacity storage | Medium‑/high‑voltage distribution, grid monitoring |
| DNP3 | |||||||
| M4M 200 | Advanced power quality, power quality reporting | Active 0.01S, Reactive 1 | Modbus RTU/TCP | 24DI/24DO | Up to 127th | Massive storage | Grid custody metering, power trading |
| DNP3 | |||||||
| اللجنة الانتخابية المستقلة 61850 |
- D1M Series (System pro M Distributed Monitoring)
ABB distributed power monitoring system supporting centralized monitoring of multiple circuits, ideal for large buildings and industrial plants, with remote management via gateways.
| نموذج | الوظائف الأساسية | Monitored Circuits | تواصل | I/O | مزود الطاقة | طلب |
| D1M 10 | Centralized monitoring of 4 الدوائر | 4×three‑phase | مودبوس ار تي يو | 8DI/4DO | 24في العاصمة | Commercial buildings, multi‑story plants |
| D1M 20 | Centralized monitoring of 8 الدوائر | 8×three‑phase | Modbus RTU/TCP | 16DI/8DO | 24في العاصمة | Large shopping malls, industrial parks |
- EM Series (Smart Power Meters)
ABB economical multifunction power meters for small buildings and industrial applications, cost-effective and flexible installation.
| نموذج | الوظائف الأساسية | فئة الدقة | تواصل | I/O | مزود الطاقة | طلب |
| EM 20 | Single‑phase current/voltage measurement | Active 1, Reactive 2 | لا أحد | لا أحد | No auxiliary power | Residential, المحلات التجارية الصغيرة |
| EM 100 | Single‑phase full‑electrical measurement | Active 0.5S, Reactive 2 | Optional Modbus | 2DI/2DO | 100–230V AC/DC | Small commercial, دوائر الإضاءة |
| EM 200 | Three‑phase full‑electrical measurement | Active 0.5S, Reactive 2 | Optional Modbus | 4DI/4DO | 100–230V AC/DC | Small factories, مباني المكاتب |
| EM 400 | Three‑phase full‑electrical + الإخراج التناظري | Active 0.2S, Reactive 2 | Optional Modbus | 4DI/4DO | 100–230V AC/DC | Process control, equipment interlock |
| 2إلى |
- Other Series (تطبيقات خاصة)
| مسلسل | نموذج | الوظائف الأساسية | سيناريوهات التطبيق |
| IM Series | IM302 | Smart power monitoring, event recording | الأتمتة الصناعية, equipment monitoring |
| LNP3 Series | LNP301 | Energy metering, remote meter reading | Public utilities, smart grids |
| PMU Series | PMU6000 | Multifunction measurement, power quality analysis | Large‑scale industry, energy management |
سابعا. Selection Guide (By Application)
- Basic energy metering: Choose M1M 10/12 or EM 20/100, low cost, meets basic statistical needs
- General power monitoring: Choose M1M 15/20 or M2M 10, full functions, supports Modbus communication
- Power quality analysis: Choose M1M 30 or M2M 20/30, harmonic analysis up to 40th/63rd, supports event recording
- Medium-/high-voltage distribution: Choose M4M series, high-accuracy measurement, complete power quality analysis, supports IEC 61850
- Multi-circuit centralized monitoring: Choose D1M series, distributed architecture, reduces wiring and costs-
ثامنا. Core Technical Parameter Comparison
| مسلسل | Measurement Accuracy | التحليل التوافقي | Communication Protocols | I/O Capacity | تصاعد | عرض |
|---|---|---|---|---|---|---|
| M1M | 0.5S ~ 0.2S | Up to 40th | Modbus RTU/TCP | 0~2DI/2DO | DIN rail | 18مم |
| M2M | 0.2S ~ 0.05S | Up to 63rd | Modbus RTU/TCP إيثرنت/IP | 2~8DI/DO | Panel mount | 96مم |
| M4M | 0.02S ~ 0.01S | Up to 127th | Modbus RTU/TCP DNP3 اللجنة الانتخابية المستقلة 61850 | 16~24DI/DO | Standalone / 19″ rack | 19″ |
| D1M | 0.5س | Up to 31st | Modbus RTU/TCP | 8~16DI/DO | DIN rail | 72مم |
| EM | 0.5S ~ Class 1 | Up to 15th | Optional Modbus | 0~4DI/DO | DIN rail | 36مم |
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية