The ABB GSH201 AC-C16 is a 1P+N-pole Residual Current Circuit Breaker with Overcurrent Protection (RCBO). It integrates three core functions: حماية الزائد, حماية ماس كهربائى, and residual current protection. With a rated current of 16A, a Type C tripping curve, and an Type AC residual current detection type, its rated residual operating current is typically 30mA ...

  • تفاصيل المنتج

The ABB GSH201 AC-C16 is a 1P+N-pole Residual Current Circuit Breaker with Overcurrent Protection (RCBO). It integrates three core functions: حماية الزائد, حماية ماس كهربائى, and residual current protection. With a rated current of 16A, a Type C tripping curve, and an Type AC residual current detection type, its rated residual operating current is typically 30mA (the complete model is GSH201 AC-C16/0.03). As a member of the ABB Compact Home product series, it is suitable for the protection of terminal power distribution circuits in residential and commercial buildings.

  1. In-depth Analysis of Model Naming Convention
SegmentCodeMeaning
Series IdentifierGSH2011P+N-pole RCBO of the Compact Home series
Residual Current TypeتكييفDetects sinusoidal alternating residual current, suitable for pure AC loads
منحنى التعثرجTripping curve type with an instantaneous tripping range of 5-10In, applicable to conventional loads such as lighting and sockets
التصنيف الحالي16Rated operating current of 16A
Residual Operating Current0.03Rated residual operating current of 30mA (some models may feature 0.01A=10mA)
Pole Configuration1ف + ن1 phase pole + 1 neutral pole; the neutral pole remains permanently closed, and only the phase pole can be switched off

Complete Model Example: GSH201 AC-C16/0.03, Product Code: 2TAZ220111R2164

  1. Core Technical Parameters and Performance Indicators
Parameter CategorySpecific Valueوصف
الجهد المقنن230/400الخامس وSuitable for single-phase branches in single-phase and three-phase systems
التصنيف الحالي (في)16أContinuous operating current capacity
Rated Short-circuit Breaking Capacity (Icn)6الShort-circuit breaking capacity at 230/400V AC
خاصية التعثرالنوع جOverload protection: inverse time characteristic, 1.45In≤It≤1.55In (no tripping within 1 hour), 2.55In≤It≤2.85In (tripping within 2 minutes); Short-circuit protection: instantaneous tripping at 5-10In
Residual Current Protection ParametersType AC, IΔn=30mAResidual current operating time: ≤0.1s (In≤40A, IΔn≤0.03A)
Rated Residual Non-operating Current (IΔn0)15أماهThe circuit breaker shall not trip when the residual current does not exceed this value
عمر الخدمة الميكانيكية≥20,000 operationsNumber of closing and opening operation cycles
عمر الخدمة الكهربائية≥6,000 operationsNumber of closing and opening operation cycles at rated current
Width Dimension17.5ممStandard DIN rail mounting width, توفير مساحة صندوق التوزيع
طريقة التركيب35mm DIN railCompliant with IEC 60715 standard rail
درجة حرارة التشغيل-25°C ~ +55°CAdaptable to various indoor environmental conditions
درجة الحماية (تصنيف IP)IP20Protection against access to hazardous parts by fingers or solid foreign objects with diameter ≥12mm

ثالثا. Core Functions and Advantages

  1. Integration of Triple Protection Functions

حماية الزائد: Achieves inverse time protection through the thermal effect of bimetallic strips, matching the thermal characteristics of cables to prevent line overheating and aging.

Short-circuit Protection: The electromagnetic release provides instantaneous protection, quickly interrupting short-circuit current to limit fault expansion.

Residual Current Protection: Detects residual current and trips rapidly (≤0.1s) when the current exceeds the set value (30أماه), preventing personal electric shock accidents.

  1. Design and Safety Features

1P+N Structure: The neutral pole remains permanently closed to ensure the neutral line is not interrupted during power-off, enhancing safety.

Current Limiting Function: Quickly limits fault current during short-circuits, reducing the risk of line and equipment damage.

Test Button: Built-in test button for regular verification of the residual current protection function.

Mechanical Indication: Clearly displays the on/off status of the circuit breaker and the cause of tripping.

  1. Reliability and Compatibility

Complies with international and national standards such as IEC 61009-1 and GB/T 16917.1.

Features the same dimensions as the ABB SH200 series miniature circuit breakers, enabling mixed installation.

Offers strong electromagnetic interference resistance to ensure stable operation in complex electrical environments.

  1. Application Scenarios and Selection Key Points
  2. سيناريوهات التطبيق النموذجية
Application FieldApplicable LoadsSelection Advantages
توزيع الطاقة السكنيةLiving room/bedroom sockets, lighting circuits, air conditioner branchesResidual current protection prevents electric shock; Type C curve is suitable for conventional loads
Commercial BuildingsOffice sockets, public area lighting, small commercial equipment1P+N structure saves space; 30mA residual current protection complies with safety regulations
Light IndustryControl circuits of small machine tools, power supplies for testing equipmentTriple protection ensures equipment and personnel safety
Medical FacilitiesPower supplies for non-critical medical equipmentSome 10mA models (GSH201 AC-C16/0.01) can be used in environments sensitive to residual current
  1. Core Selection Steps
  2. Determine Load Type: Select Type C curve for conventional lighting and socket loads; select Type D curve for motor loads.
  3. Calculate Load Current: Ensure the 16A rated current is greater than the actual load current (a 20% margin is recommended).
  4. Select Residual Current Type: Choose Type AC for pure AC loads; choose Type A or Type AP-R for loads containing DC components (على سبيل المثال, electronic devices).
  5. Determine Residual Operating Current: Select 30mA for general locations; select 10mA for humid environments or locations with high safety requirements.
  6. Verify Breaking Capacity: Ensure the 6kA breaking capacity meets the short-circuit current requirements of the installation point.
  7. Installation and Operation Precautions
  8. مواصفات الأسلاك

Strictly distinguish between the phase pole (ل) and neutral pole (ن); the neutral line must be connected to the N terminal, and reverse connection is prohibited.

Ensure the circuit is de-energized before wiring; the cable cross-section should match the 16A rated current (1.5mm² copper core cable or above is recommended).

Tighten the terminal screws to the torque specified in the manual (usually 2.5N·m) to prevent overheating caused by poor contact.

  1. Operation and Maintenance

Verify the residual current protection function using the test button after installation.

Press the test button regularly (monthly is recommended) to check if the residual current protection is functioning properly.

After a residual current trip, identify and eliminate the fault cause before manually resetting the circuit breaker.

Avoid frequent operation; inspect the circuit breaker for damage especially after a short-circuit fault.

  1. Safety Warnings

This product cannot be used for neutral line overcurrent protection of three-phase unbalanced loads.

It cannot be used as a replacement for an isolating switch; ensure all power supplies are disconnected during power-off maintenance.

It is not suitable for use in flammable and explosive environments unless special protective measures are taken.

Follow the manufacturer’s recommendations when used in conjunction with other protective devices (على سبيل المثال, surge protectors).

  1. Comparison with Similar Products
Comparison ItemGSH201 AC-C16SH201-C16 (MCB)GSH202 AC-C16 (2ص)
وظائف الحمايةالزائد + Short-circuit + Residual Currentالزائد + Short-circuit onlyالزائد + Short-circuit + Residual Current
Pole Configuration1ف + ن2ص (two phase poles)
Neutral PolePermanently closedNo neutral poleBoth poles can be switched off
Width Dimension17.5مم17.5مم35مم
السيناريوهات القابلة للتطبيقSingle-phase residential/commercial branchesBranches requiring only overload and short-circuit protectionScenarios requiring neutral pole switching
Price RangeواسطةقليلMedium-high

As a high-performance 1P+N-pole RCBO, the ABB GSH201 AC-C16/0.03 has become the ideal choice for terminal power distribution in residential and commercial buildings due to its compact design, triple protection, and high reliability. It can not only effectively prevent overload and short-circuit faults but also provide 30mA residual current protection to safeguard personal and property safety. During selection, the tripping curve, residual current type, and residual operating current should be reasonably chosen based on the load type, current magnitude, and safety requirements to ensure optimal protection effectiveness and system compatibility.