It is not a contactor, but a CHINT NJMC1 series impulse relay, a low-power consumption bistable control electrical device.
شرح النموذج
NJMC1: Model code of CHINT impulse relay series
16: Rated contact capacity (16أ)
1ص: 1 pole (single contact)
المعلمات الأساسية
| Category | Details |
| Product Type | Mechanical bistable impulse relay |
| Contact Parameters | Resistive load: 16A/250VAC; Maximum switching power: 4000VA (AC) / 448W (العاصمة) |
| Coil Parameters | Voltage range: AC 12~380V / DC 6~220V; Triggered only by pulse signal (no continuous power supply required) |
| Service Life | الحياة الكهربائية: 1×10⁵ operations; الحياة الميكانيكية: 2×10⁶ operations |
| Operating Environment | Temperature: -25℃~+55℃; Pollution degree: 1; Overvoltage category: Ⅱ |
| طريقة التركيب | 35mm DIN rail mounting |
| أبعاد | 86×70×18mm |
Core Features
Bistable Design: The contact state is switched by pulse signal (duration 50ms~1s). No continuous power supply is needed after switching, featuring ultra-low power consumption (different from the continuous power supply of ordinary relays).
High Compatibility: Complete AC/DC coil voltage specifications, suitable for different control circuits.
Miniaturization: حجم صغير, suitable for dense control cabinet layout.
التطبيقات النموذجية
Suitable for low-power on-off control scenarios, مثل:
– Energy-saving control of lighting circuits
– Switching of small loads (على سبيل المثال, solenoid valves, indicator lights)
– Signal-triggered on-off circuits in automation equipment
Full Specification Selection Table of CHINT NJMC1 Series Impulse Relays
(ملحوظة: All series adopt mechanical bistable design, triggered only by pulse signal, no continuous power supply required after switching, low power consumption and energy saving)
| Model | عدد البولنديين | التصنيف الحالي | Contact Configuration | Optional Coil Voltage Specifications | Rated Load (Resistive) | طريقة التركيب | أبعاد (الطول × العرض × الارتفاع) | وزن (approx.) |
| NJMC1-10/1P | 1ص | 10أ | 1 changeover contact (1CO) | AC: 12V/24V/110V/220V/380V; العاصمة: 6V/12V/24V/48V/110V/220V | AC 10A/250V (3000VA); DC 10A/24V (240W) | 35mm DIN Rail | 86×70×18mm | 85ز |
| NJMC1-10/2P | 2ص | 10أ | 2 changeover contacts (2CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×36mm | 150ز |
| NJMC1-10/3P | 3ص | 10أ | 3 changeover contacts (3CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×54mm | 210ز |
| NJMC1-10/4P | 4ص | 10أ | 4 changeover contacts (4CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×72mm | 270ز |
| NJMC1-16/1P | 1ص | 16أ | 1 changeover contact (1CO) | AC: 12V/24V/110V/220V/380V; العاصمة: 6V/12V/24V/48V/110V/220V | AC 16A/250V (4000VA); DC 16A/24V (384W) | 35mm DIN Rail | 86×70×18mm | 90ز |
| NJMC1-16/2P | 2ص | 16أ | 2 changeover contacts (2CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×36mm | 160ز |
| NJMC1-16/3P | 3ص | 16أ | 3 changeover contacts (3CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×54mm | 225ز |
| NJMC1-16/4P | 4ص | 16أ | 4 changeover contacts (4CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×72mm | 290ز |
| NJMC1-20/1P | 1ص | 20أ | 1 changeover contact (1CO) | AC: 12V/24V/110V/220V/380V; العاصمة: 6V/12V/24V/48V/110V/220V | AC 20A/250V (5000VA); DC 20A/24V (480W) | 35mm DIN Rail | 86×70×18mm | 95ز |
| NJMC1-20/2P | 2ص | 20أ | 2 changeover contacts (2CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×36mm | 170ز |
| NJMC1-20/3P | 3ص | 20أ | 3 changeover contacts (3CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×54mm | 240ز |
| NJMC1-20/4P | 4ص | 20أ | 4 changeover contacts (4CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×72mm | 310ز |
| NJMC1-25/1P | 1ص | 25أ | 1 changeover contact (1CO) | AC: 12V/24V/110V/220V/380V; العاصمة: 6V/12V/24V/48V/110V/220V | AC 25A/250V (6250VA); DC 25A/24V (600W) | 35mm DIN Rail | 86×70×18mm | 100ز |
| NJMC1-25/2P | 2ص | 25أ | 2 changeover contacts (2CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×36mm | 180ز |
| NJMC1-25/3P | 3ص | 25أ | 3 changeover contacts (3CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×54mm | 255ز |
| NJMC1-25/4P | 4ص | 25أ | 4 changeover contacts (4CO) | Same as 1P specification | Same as 1P specification | 35mm DIN Rail | 86×70×72mm | 330ز |
Key Selection Instructions (Essential for Sales/Quotation Scenarios)
- Core Selection Dimensions:
– عدد البولنديين (1P~4P): Select according to the number of control circuits (على سبيل المثال, 1P for single-circuit lighting, 3P for three-phase equipment);
– التصنيف الحالي (10A/16A/20A/25A): Load current ≤ 80% of rated current (على سبيل المثال, it is recommended that the load of 16A model ≤ 12.8A);
– الجهد لفائف: Must match the customer’s control circuit voltage (AC 220V and DC 24V are the most commonly used specifications, which can be recommended first in quotation).
- Load Compatibility:
– Suitable for resistive loads (lighting, أفران المقاومة) and low-power inductive loads (small solenoid valves, fans). For capacitive loads, derating by 50% مطلوب.
- Quotation and Supply Tips:
– Regular coil voltages (تيار متردد 220 فولت, DC24V) are in sufficient stock, while special voltages (على سبيل المثال, AC12V, DC6V) need to be stocked 3~5 days in advance;
– Tiered prices are available for bulk purchases (≥ 100 وحدات). Neutral packaging or CHINT original packaging is supported for export orders (to be specified in advance).
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية





















NH42-63-318x560.png)



