CHINT NXBLE-63YH-C20 RCOCB - المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية

قاطع الدائرة/

CHINT NXBLE-63YH-C20 RCOCB

Model Segmentوصف
NXBLEProduct series code; NXB is the basic series of CHINT miniature circuit breakers, L indicates residual current protection (earth leakage), and E indicates high breaking capacity
63Rated frame current is 63A. The maximum current carrying capacity of this series of circuit breakers is 63A, and C20 is the rated breaking current, which must be less than the frame current
YHSpecial function/specification code; in this CHINT series, YH usually represents the combined function of arc fault detection device (AFDD) + residual current operated circuit breaker (RCCB/RCBO). It can detect arc faults and trip quickly, improving electrical safety
C20C-type tripping curve with a rated current of 20A; C-type tripping curve is suitable for lighting and general power loads (such as motors, fans, إلخ.), with an instantaneous tripping current of 5~10In (In=20A, أي., 100~200A)

  • تفاصيل المنتج

CHINT NXBLE-63YH-C20 is a residual current operated قاطع الدائرة (earth leakage circuit breaker), belonging to the NXBLE series. It is mainly designed for overload, short-circuit and earth leakage protection in low-voltage distribution lines, and suitable for various scenarios such as industrial and civil applications.

Model Parameter Interpretation

Model Segmentوصف
NXBLEProduct series code; NXB is the basic series of CHINT miniature circuit breakers, L indicates residual current protection (earth leakage), and E indicates high breaking capacity
63Rated frame current is 63A. The maximum current carrying capacity of this series of circuit breakers is 63A, and C20 is the rated breaking current, which must be less than the frame current
YHSpecial function/specification code; in this CHINT series, YH usually represents the combined function of arc fault detection device (AFDD) + residual current operated circuit breaker (RCCB/RCBO). It can detect arc faults and trip quickly, improving electrical safety
C20C-type tripping curve with a rated current of 20A; C-type tripping curve is suitable for lighting and general power loads (such as motors, fans, إلخ.), with an instantaneous tripping current of 5~10In (In=20A, أي., 100~200A)

Core Technical Parameters (Default Standard Configuration, Subject to Nameplate for Specific Details)

  1. الجهد المقنن: Single-phase 230V AC, three-phase 400V AC (commonly used in single-phase scenarios)
  2. Rated Frequency: 50Hz/60Hz
  3. Residual Current Operation Parameters:

Rated residual operating current (IΔn): commonly 30mA (standard safety value for household/industrial use, which can cut off the power supply quickly to prevent electric shock); 10mA/300mA is available for customization in some models

Operating time: ≤0.1s (instantaneous protection against short-circuit/earth leakage); the operating time of arc fault protection complies with national standard requirements

  1. كسر القدرة: High breaking capacity (Class E), usually 6kA/10kA (may vary by batch, please check the nameplate), capable of withstanding high current impact during line short-circuit
  2. Tripping Type: C-type tripping, suitable for conventional loads to avoid non-fault tripping
  3. طريقة التركيب: تركيب السكك الحديدية DIN (compliant with DIN rail standard, 35mm rail, facilitating batch installation in distribution cabinets)
  4. رقم القطب: Commonly 1P+N, 2ص (please check the specific model; C20 specification is mostly 1P+N/2P, suitable for single-phase 220V lines)

سيناريوهات التطبيق

Lighting and socket circuits in civil buildings such as residences, office buildings and shopping malls, providing dual protection against electric shock and electrical fire (arc fault + earth leakage)

Small power equipment and control circuits in industrial plants, protecting equipment and the safety of operators

Places sensitive to arc faults (such as old lines and lines around flammable materials); the AFDD function can effectively reduce the risk of fire caused by arcs

Alternative Reference of Corresponding Schneider Model (Selection with the Same Function)

For brand replacement, you can refer to Schneider iDPNa Vigi+ AFDD series, such as iDPNa Vigi+ AFDD C20 30mA. The core parameters are matched: 20A rated current, C-type tripping, 30mA earth leakage protection, arc fault protection. The mounting method and breaking capacity are similar, allowing direct replacement (please check if the pole number, voltage and mounting dimensions are consistent).

احتياطات التثبيت والاستخدام

  1. قبل التثبيت, confirm that the line voltage and current match the parameters of the circuit breaker to avoid faults caused by overload or undervoltage
  2. Wiring must be done according to the marks on the terminals (L for live wire, N for neutral wire, PE for protective earth wire); reverse connection is strictly prohibited for 1P+N models
  3. Regular Testing: Press the “امتحان” button of the circuit breaker once a month to check whether the earth leakage/arc protection function is normal
  4. Avoid use in humid, dusty and corrosive environments, which may affect the service life and operation reliability of the circuit breaker
  5. Cut off the upper-level power supply before replacement; live operation is strictly prohibited

Common Fault Troubleshooting

Fault PhenomenonTroubleshooting Direction
التعثر المتكرر1. Load overload (على سبيل المثال, starting multiple high-power devices at the same time); 2. Line leakage (insulation damage, dampness); 3. Arc fault (line aging, loose joints); 4. Circuit breaker itself failure (test button invalid, need replacement)
No Tripping1. Damaged test button; 2. Residual current protection module failure; 3. Wrong wiring (على سبيل المثال, neutral wire not connected)

Parameter Comparison Table Between CHINT NXBLE-63YH-C20 and Corresponding Schneider Model

To facilitate your direct procurement and replacement, the following is a complete parameter comparison between CHINT NXBLE-63YH-C20 (1P+N/2P) and Schneider iC65N Vigi+ C20 (1P+N model: A9D65140; 2P model: A9D65240), covering core technical indicators and application compatibility.

Parameter CategoryCHINT NXBLE-63YH-C20Schneider iC65N Vigi+ C20Replacement Compatibility
Basic Information
Product ModelNXBLE-63YH-C20 (1P+N/2P)1ف + ن: A9D65140Fully Compatible
2ص: A9D65240
Product SeriesNXBLE Series (upgraded replacement for DZ47LE)Acti9 iC65 SeriesBoth are mainstream series for terminal power distribution
Product TypeResidual current operated circuit breaker (earth leakage MCB)Residual current operated circuit breaker (earth leakage MCB)Consistent Function
Core Electrical Parameters
رقم القطب1ف + ن / 2ص1ف + ن / 2صFully Matched
التصنيف الحالي (في)20أ (C-curve)20أ (C-curve)Completely Consistent
منحنى التعثرC-type (instantaneous tripping 5~10 In)C-type (instantaneous tripping 5~10 In)Completely Consistent
كسر القدرة (Icn)6ال (YH mark indicates high breaking capacity)6ال (N mark indicates standard breaking capacity)Fully Matched
Rated Residual Operating Current (IΔn)30أماه (Type AC)30أماه (Type A, compatible with Type AC leakage)Functionally Compatible
Leakage Operating Time≤0.1s (safety standard for electric shock protection)≤0.1s (compliant with IEC/GB standards)Completely Consistent
تصنيف العمل الجهدالتيار المتناوب 230 فولت/400 فولتالتيار المتناوب 230 فولت/400 فولتCompletely Consistent
تصنيف الجهد العزل400V400VCompletely Consistent
Physical and Installation Parameters
طريقة التركيب35mm DIN rail mounting35mm DIN rail mountingFully Compatible
Wiring MethodTop-in bottom-out (horizontal/vertical mounting available)Top-in bottom-out (standard DIN mounting)Consistent Operation
فئة الحمايةIP20 (finger protection)IP20 (IP40 for front side, IP20 for terminals)Suitable for distribution box application
Width Dimension1ف + ن: 36مم1ف + ن: 36ممConsistent dimensions, enabling direct replacement
2ص: 72مم2ص: 72مم
Standards and Certifications
Executive StandardsGB 10963.1, GB 13955اللجنة الانتخابية المستقلة 60898, GB 10963.1, GB 13955Both comply with national standards and are applicable in China
CertificationCCC Certificationسي سي سي, CE CertificationBoth meet domestic application requirements
Special Functions and Maintenance
Test FunctionEquipped with TEST button (monthly test required)Equipped with TEST button (monthly test required)Consistent Operation
TerminalScrew tightening, suitable for 1.5~6mm² wiresScrew tightening, suitable for 1.5~6mm² wiresCompatible with the same wire diameter
درجة حرارة التشغيل-25°C ~ +40°C-25°C ~ +40°CConsistent operating environment

Key Precautions for Replacement

  1. Pole Number Matching: Confirm whether the original circuit is 1P+N or 2P, and select the corresponding Schneider model with the same pole number
  2. Leakage Type: Schneider adopts Type A earth leakage protection (compatible with Type AC), while CHINT uses Type AC. Type A has a wider application range, and replacement is risk-free
  3. Wiring Distinction: For 1P+N models, strictly distinguish between neutral wire (ن) and live wire (ل); reverse connection is prohibited
  4. Installation Space: The two models have the same width dimension and can directly replace the original installation position

Procurement Suggestions

For cost optimization: Choose CHINT NXBLE-63YH-C20 with higher cost performance

For brand consistency: Choose Schneider iC65N Vigi+ C20 with better compatibility with Schneider systems

For inventory replacement: The two models can be directly interchanged without modifying the circuit design or wiring method