GV3P80 is a 3‑pole thermal‑magnetic motor circuit breaker from Schneider Electric TeSys GV3 series. It has an adjustment current range of 70–80A, suitable for 45kW (400V) / 55كيلوواط (690V) three‑phase motors. It integrates triple protection (الزائد, short‑circuit, فشل المرحلة) and isolation function, serving as a core protection component in industrial motor circuits. Model Explanation GV3: ...

  • تفاصيل المنتج

GV3P80 is a 3‑pole thermal‑magnetic motor circuit breaker from Schneider Electric TeSys GV3 series. It has an adjustment current range of 70–80A, suitable for 45kW (400V) / 55كيلوواط (690V) three‑phase motors. It integrates triple protection (الزائد, short‑circuit, فشل المرحلة) and isolation function, serving as a core protection component in industrial motor circuits.

  1. شرح النموذج

GV3: TeSys GV3 motor circuit breaker series (frame size 3)

ص: Thermal‑magnetic release (triple protection: الزائد + short‑circuit + فشل المرحلة)

80: Rated current 80A, adjustable range 70–80A (continuously adjustable)

  1. Key Specifications (Full Data)
غرضمواصفة
البولنديين3ص (three‑phase)
Adjustment current range70–80A (continuously adjustable)
Trip typeThermal‑magnetic
Short‑circuit trip multiplier14×In (1120أ)
Breaking capacity Icu65kA @ 230V; 50kA @ 400V; 6kA @ 690V
Rated operational voltage Ue690فولت تيار متردد 50/60 هرتز
Insulation voltage Ui690الخامس و
Impulse withstand voltage Uimp6كيلو فولت
قوة المحرك المناسبة45kW @ 400V; 55kW @ 690V; 22kW @ 230V
TerminalsEverLink screw terminals (25–35mm² cable)
تصاعدDIN rail (width 55mm), screw mountable
Degree of protectionIP20 (front)
درجة حرارة التشغيل-20°C ~ +60°C (derating factor: 0.8 at +60°C)
Mechanical endurance50,000 operating cycles
Electrical endurance20,000 دورات (category AC‑3)
Isolation functionComplies with IEC 60947‑1, can be used as safety isolator
الشهاداتسي سي سي, م, أول, وكالة الفضاء الكندية, IEC 60947‑4‑1
وزنتقريبا. 1.02 كجم
أبعاد (العرض × الارتفاع × العمق)55 × 105 × 78 مم
  1. الوظائف الأساسية & Advantages
  2. Triple Protection

Thermal trip: Overload inverse‑time protection (simulates motor heating characteristics)

Magnetic trip: Short‑circuit instantaneous protection (fixed 14×In)

حماية فشل المرحلة: Automatic trip under three‑phase unbalance (IEC 60947‑4‑1)

  1. EverLink Terminal Technology

Maintenance‑free, anti‑loosening, oxidation‑resistant, suitable for large‑section cables, reduces wiring failure risks.

  1. تصميم السلامة

Knob operation, lockable in OFF position (up to 3 padlocks)

Clear current scale for precise adjustment

Complies with IEC isolation standards, usable as motor circuit isolator

  1. Wide Environmental Adaptability

Operating altitude: ≤3000m (no derating required)

Vibration resistance: 10–150Hz, 0.5mm amplitude

Shock resistance: 5Gn (11آنسة); 30Gn (1آنسة)

  1. Selection Reference (TeSys GV3 Series)
نموذجAdjustment CurrentSuitable Power (400V)Trip Typeسمات
GV3P6555–65A37كيلوواطThermal‑magneticمعيار, EverLink terminals
GV3P8070–80A45كيلوواطThermal‑magneticThis model, max adjustment current
GV3L8070–80A45كيلوواطMagneticShort‑circuit protection only
GV3ME8040–80A45كيلوواطThermal‑magnetic3‑step adjustment (40–50/63–80), economy version
GV3P4030–40A22كيلوواطThermal‑magneticFor small‑medium motors
  1. التطبيقات

Direct starting / star‑delta starting circuits for three‑phase asynchronous motors

Main circuit protection for fans, مضخات, الضواغط, الناقلات, machine tools

Industrial automation lines, construction equipment motor control

Motor circuits requiring isolation and safety interlock (على سبيل المثال, emergency stop loops)

Motors with frequent starting/stopping and fluctuating loads

  1. Replacement Options
  2. Schneider same series

GV3L80 (short‑circuit only, تكلفة أقل)

GV3ME80 (simplified adjustment, same mounting space)

  1. Competitor alternatives

سيمنز: 3RV1041‑4JA10 (70–80A, 3ص, thermal‑magnetic)

ايه بي بي: MS165‑80 (70–80A, 3ص, thermal‑magnetic)

Chinese brands: Chint NM1‑125S, Delixi CDM1‑125 (motor protection curve matching required)

  1. ترقية الحل

Schneider GV4P08N (frame 4, higher breaking capacity, for motors above 55kW)

Selection Tips

  1. Select adjustment range at 1.1–1.25 × motor rated current
  2. Confirm breaking capacity meets system short‑circuit current requirements
  3. For isolation function, prefer models with certified isolation
  4. For limited wiring space, choose EverLink terminal models to reduce faults

Complete Model List of Schneider Electric TeSys GV Series Motor Circuit Breakers

Schneider TeSys GV series motor circuit breakers include six sub‑series: GV1, GV2, GV3, GV4, GV5, GV6, covering an adjustment range from 0.06A to 800A, suitable for 0.03kW to 400kW (400V) three‑phase motors, with thermal‑magnetic, magnetic, and economy thermal‑magnetic protection types.

  1. GV1 Series (Miniature, discontinued, replaced by GV2ME)

GV1ME01: 0.1–0.16A

GV1ME02: 0.16–0.25A

GV1ME03: 0.25–0.4A

GV1ME04: 0.4–0.63A

GV1ME05: 0.63–1.0A

GV1ME06: 1.0–1.6A

GV1ME07: 1.6–2.5A

GV1ME08: 2.5–4.0A

  1. GV2 Series (صغير, 0.06–16A, 0.03–15kW/400V)

2.1 GV2P (Thermal‑magnetic, الحماية الكاملة, knob)

نموذجAdjustment CurrentSuitable Power (400V)
GV2P010.1–0.16A0.06كيلوواط
GV2P020.16–0.25A0.12كيلوواط
GV2P030.25–0.4A0.2كيلوواط
GV2P040.4–0.63A0.37كيلوواط
GV2P050.63–1.0A0.55كيلوواط
GV2P061.0–1.6A0.75كيلوواط
GV2P071.6–2.5A1.5كيلوواط
GV2P082.5–4.0A2.2كيلوواط
GV2P104.0–6.3A3كيلوواط
GV2P146.3–10A4كيلوواط
GV2P1610–16A7.5كيلوواط

2.2 GV2L (Magnetic, short‑circuit only, knob)

نموذجAdjustment CurrentSuitable Power (400V)
GV2L010.1–0.16A0.06كيلوواط
GV2L020.16–0.25A0.12كيلوواط
GV2L030.25–0.4A0.2كيلوواط
GV2L040.4–0.63A0.37كيلوواط
GV2L050.63–1.0A0.55كيلوواط
GV2L061.0–1.6A0.75كيلوواط
GV2L071.6–2.5A1.5كيلوواط
GV2L082.5–4.0A2.2كيلوواط
GV2L104.0–6.3A3كيلوواط
GV2L146.3–10A4كيلوواط
GV2L1610–16A7.5كيلوواط
GV2L2014–20A11كيلوواط
GV2L2218–25A15كيلوواط

2.3 GV2ME (Economy thermal‑magnetic, pushbutton, 3‑step)

نموذجAdjustment CurrentSuitable Power (400V)
GV2ME010.1–0.16A0.06كيلوواط
GV2ME020.16–0.25A0.12كيلوواط
GV2ME030.25–0.4A0.2كيلوواط
GV2ME040.4–0.63A0.37كيلوواط
GV2ME050.63–1.0A0.55كيلوواط
GV2ME061.0–1.6A0.75كيلوواط
GV2ME071.6–2.5A1.5كيلوواط
GV2ME082.5–4.0A2.2كيلوواط
GV2ME104–6.3A3كيلوواط
GV2ME146.3–10A4كيلوواط
GV2ME1610–16A7.5كيلوواط

2.4 GV2LE (Magnetic with electronic trip, special applications)

GV2LE01 ~ GV2LE22: matching current ratings as GV2L, with electronic trip

  1. GV3 Series (واسطة, 9–80A, 5.5–45kW/400V, 55mm width)

3.1 GV3P (Thermal‑magnetic, الحماية الكاملة, EverLink)

نموذجAdjustment CurrentSuitable Power (400V)
GV3P139–13A5.5كيلوواط
GV3P1813–18A11كيلوواط
GV3P2518–25A15كيلوواط
GV3P3223–32A18.5كيلوواط
GV3P4030–40A22كيلوواط
GV3P5040–50A30كيلوواط
GV3P6555–65A37كيلوواط
GV3P7365–73A45كيلوواط
GV3P8070–80A45كيلوواط

3.2 GV3L (Magnetic, short‑circuit only)

GV3L25: 18–25A

GV3L32: 23–32A

GV3L40: 30–40A

GV3L50: 40–50A

GV3L65: 55–65A

GV3L80: 70–80A

3.3 GV3ME (Economy thermal‑magnetic, 3‑step)

نموذجAdjustment CurrentSuitable Power (400V)
GV3ME4040–50A30كيلوواط
GV3ME6350–63A37كيلوواط
GV3ME8040–80A (3 خطوات: 40–50/63–80)45كيلوواط
  1. GV4 Series (كبير, 25–115A, 15–55kW/400V, 81mm width)

4.1 GV4P (Thermal‑magnetic, الحماية الكاملة)

نموذجAdjustment CurrentSuitable Power (400V)
GV4P2525–32A18.5كيلوواط
GV4P4032–40A22كيلوواط
GV4P5040–50A30كيلوواط
GV4P6350–63A37كيلوواط
GV4P8063–80A45كيلوواط
GV4P10080–100A55كيلوواط
GV4P115100–115A55كيلوواط

4.2 GV4L / GV4LE (Magnetic type)

GV4L25 ~ GV4L115: matching current ratings as GV4P

GV4LE25 ~ GV4LE115: magnetic with electronic trip

4.3 Special GV4 Models

GV4PB80S: UL489 approved, 63–80A

GV4P02N: 2‑pole thermal‑magnetic, special applications

  1. GV5 / GV6 Series (Extra‑large, 100–800A, 55–400kW/400V)

GV5P100: 80–100A

GV5P125: 100–125A

GV5P160: 125–160A

GV5P200: 160–200A

GV6P250: 200–250A

GV6P315: 250–315A

GV6P400: 315–400A

GV6P500: 400–500A

GV6P630: 500–630A

GV6P800: 630–800A

 

  1. Model Naming Rules
Letter/Numberمعنى
GVTeSys GV series motor circuit breaker
1/2/3/4/5/6Frame size (1 = smallest, 6 = largest)
صThermal‑magnetic trip (الزائد + short‑circuit + فشل المرحلة)
لMagnetic trip (short‑circuit only)
MEEconomy thermal‑magnetic trip (3‑step, cost‑optimized)
LEMagnetic trip with electronic functions
NumberCurrent rating (على سبيل المثال, 80 = 70–80A)
  1. دليل الاختيار السريع
  2. Select adjustment range at 1.1–1.25 × motor rated current
  3. For full protection (الزائد + short‑circuit + فشل المرحلة): choose P series
  4. If thermal protection exists (على سبيل المثال, VFD): choose L series (short‑circuit only)
  5. Cost‑sensitive, simple adjustment: choose ME series (3‑step)
  6. المحركات الصغيرة (≤15kW): GV2; واسطة (15–45kW): GV3; كبير (≥55kW): GV4–GV6
  7. ملحوظات
  8. All models are 3‑pole (3ص) for three‑phase asynchronous motors
  9. Protection characteristics comply with IEC 60947‑4‑1
  10. كسر القدرة: GV2/GV3 100kA@400V; GV4 65kA@400V
  11. تصاعد: 35mm standard DIN rail
  12. Degree of protection: IP20 (front operating part)