ويشات: +86-13184948252 واتس اب: 0086-13811255435 بريد إلكتروني: كينت@bestcontactor.com

عن اتصال |

 LS ELECTRIC ABE404B-4P-400A MCCB - المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية

قاطع الدائرة/

LS ELECTRIC ABE404B-4P-400A MCCB

  Model Part Meaning ABE Series code, Meta-MEC economy MCCB, thermal-magnetic trip, low breaking capacity (economy type) 40 Frame rating current 400A 4 4 أقطاب (4ص), suitable for three-phase four-wire system protection B Breaking capacity class B (10kA@AC380V) 400A Rated operational current 400A, set by plug module Key Technical Parameters Item Specification Description Product Type ...

  • تفاصيل المنتج

 

Model Partمعنى
ABEرمز السلسلة, Meta-MEC economy MCCB, thermal-magnetic trip, low breaking capacity (economy type)
40Frame rating current 400A
44 أقطاب (4ص), suitable for three-phase four-wire system protection
بBreaking capacity class B (10kA@AC380V)
400أRated operational current 400A, set by plug module
  1. المعلمات التقنية الرئيسية
غرضمواصفةوصف
Product Typeاقتصاد Molded Case Circuit Breaker (مكب)Thermal-magnetic trip, fixed mount
الجهد المقننAC 600V, Ui 690Vيتوافق مع اللجنة الانتخابية المستقلة 60947-2
التردد المقدر50/60هرتزUniversal frequency range
كسر القدرةIcu=10kA@AC380VClass B economy breaking capacity
Trip TypeFixed thermal-magnetic tripحماية الزائد (inverse time) + حماية ماس كهربائى (instantaneous)
تصنيف الجهد العزلUi=690VMaximum voltage for insulation performance
Mechanical Endurance8500 العملياتStandard operating cycles
Electrical Endurance1000 العملياتOperating cycles at rated current
نوع التركيبFixed typeStandard 35mm DIN rail or panel mount
ConnectionFront connection / Rear connectionOptional for different installations
Applicable Standardsاللجنة الانتخابية المستقلة 60947-1/2, في 60947-1/2International electrical standards
  1. Series Model List (400AF Frame)
نموذجالبولنديينكسر القدرةالنطاق الحالي المقدر
ABE402b10ال250أ, 300أ, 350أ, 400أ
ABE403b10ال250أ, 300أ, 350أ, 400أ
ABE404b10ال250أ, 300أ, 350أ, 400أ
ABS402b25ال250أ, 300أ, 350أ, 400أ
ABS403b25ال250أ, 300أ, 350أ, 400أ
ABS404b25ال250أ, 300أ, 350أ, 400أ
ABH402b35ال250أ, 300أ, 350أ, 400أ
ABH403b35ال250أ, 300أ, 350أ, 400أ
ABH404b35ال250أ, 300أ, 350أ, 400أ
  1. Recommended International Brand Replacements
ماركةمسلسلنموذج الاستبدالمعلمات المطابقة الرئيسية
شنايدرEZD SeriesEZD400E44004ص, 400أ, 10ال, thermal-magnetic trip
سيمنز3VT Series3VT8440-1AA034ص, 400أ, 10ال, thermal-magnetic trip
ايه بي بيTmax SeriesT2N400 TMD 400/400 FF 4P4ص, 400أ, 10ال, thermal-magnetic trip
إيتونPower DefenseLZMN4-A400-I4ص, 400أ, 10ال, thermal-magnetic trip
تشانغشو التبديلCM3 SeriesCM3-400M/4300B 400A4ص, 400أ, 10ال, thermal-magnetic trip
  1. التطبيقات & Selection Notes
  2. التطبيقات النموذجية

End protection in low-voltage distribution systems, على سبيل المثال, lighting and power distribution in commercial buildings and industrial plants

Three-phase asynchronous motor protection (≤200kW, 380V)

Capacitor bank protection

Small generator outlet protection

  1. Selection Guidelines

Confirm system voltage (≤600V) and frequency (50/60هرتز)

Calculate circuit rated current to ensure 400A meets long‑term operation

Evaluate short-circuit level: if >10ال, use higher breaking capacity ABS (25ال) or ABH (35ال) مسلسل

Consider pole requirement: 4P for neutral protection applications

Confirm mounting (fixed/drawout) and connection direction (front/rear)

  1. ميزات المنتج & Advantages
  2. Economical & Practical: ABE series is cost-effective for budget‑limited projects
  3. Standard Design: Complies with IEC standards, interchangeable with other brands
  4. Reliable Protection: Thermal-magnetic trip provides basic overload and short-circuit protection
  5. Flexible Installation: Supports front/rear wiring and multiple mounting methods
  6. Complete Accessories: Can be equipped with auxiliary contacts, alarm contacts, undervoltage release, إلخ.
  7. صيانة & استكشاف الأخطاء وإصلاحها
  8. التفتيش المنتظم: Inspect appearance and tighten terminals quarterly to avoid looseness or overheating
  9. Trip Test: Perform manual trip test annually to verify mechanical reliability
  10. استكشاف الأخطاء وإصلاحها:

Frequent overload tripping: Check load or replace with higher rated model

Short-circuit tripping: Locate and repair short circuit before closing

Failure to close: Check mechanical jam or replace damaged parts

LS ELECTRIC ABE404B-4P-400A is an economy 4-pole MCCB with 400A rated current and 10kA breaking capacity, suitable for low-voltage distribution systems with moderate breaking requirements. For higher breaking capacity, use ABS (25ال) or ABH (35ال) مسلسل.

Applications of LS ELECTRIC ABE404B-4P-400A MCCB

تحديد المواقع الأساسية:

This 4-pole economy MCCB (4ص, 400أ, 10ال) is mainly used for end protection in low‑voltage distribution systems, especially where neutral protection is required, short-circuit current ≤10kA, and budget is limited.

  1. Commercial Building Distribution
طلبSuitabilitySelection Tip
Main distribution board main breaker4P protects 3-phase 4-wire; 400A fits small‑to‑medium commercial buildingsTotal load ≤320A (80% duty), short-circuit ≤10kA
Main A/C protection400A for large central A/C units (≤200kW, 380V)Match compressor inrush; recommend undervoltage release
Emergency lighting4P ensures neutral continuity for reliable emergency operationUse with EPS/UPS; front connection for easy maintenance
Elevator room power400A for multiple elevators; 4P prevents neutral faultsInstall in dedicated cabinet; ensure ventilation

Typical Cases:

3–5 story office buildings, chain supermarkets, hotels as main or important branch breaker.

  1. Industrial Plant Applications
  2. General Machinery

Main breaker for small‑medium production lines: 400A covers multiple branches; 10kA suits general industrial short-circuit levels

Motor group protection: Total power ≤200kW, used with thermal relays for precise protection

Auxiliary equipment: المشجعين, مضخات, الضواغط; 4P for control circuits with neutral

  1. Specific Industries

Food processing: Cost-effective for light industry; 4P ensures safety and quality

Electronic assembly: 400A for multiple lines; 4P avoids neutral drift affecting precision equipment

Warehouse power: Main breaker for lighting and forklift charging

Warning:

If short-circuit current >10ال, upgrade to LS ABS (25ال) or ABH (35ال).

  1. Public & Residential Buildings
  2. Education & Medical

School main distribution: 4P protects lighting, A/C, غرف الكمبيوتر; 400A for whole building

Community hospital: 4P for medical equipment with neutral; economy for primary care

Stadium auxiliary systems: إضاءة, audio, seats; 400A for local zones

  1. بنية تحتية

Small wastewater treatment: 400A for pumps and blowers; 4P prevents control system failure

Urban landscape lighting: Main breaker for multi-loop lighting with reliable neutral

Small waste transfer station: 400A for compressors and conveyors; low operating cost

  1. Special Applications
  2. Capacitor Bank Protection

For capacitor banks ≤100kvar; 4P prevents inrush and short-circuit during switching

Recommend adding SPD for surge protection

  1. Small Generator Systems

Main breaker for generators ≤300kVA; 4P ensures safe isolation from grid

Used with synchronizing equipment for smooth switch between mains and generator

  1. Temporary Power

Construction site temporary power main breaker; 400A for cranes, welders

4P suitable for harsh site conditions; prevents electric shock from broken neutral

  1. Key Selection & Application Criteria
FactorمُستَحسَنNot Suitable For
Short-circuit level≤10kA: مناسب; >10ال: use ABS/ABHHigh-risk areas (chemical, mining) مع >10ال
Load typeResistive & inductive loads (إضاءة, المحركات)Large rectifiers, arc furnaces, high nonlinear loads
Earthing systemTN-S, TT systems (4P neutral protection)أنظمة تكنولوجيا المعلومات (operating rooms, mines)
EnvironmentIndoor dry, ≥40 درجة مئويةOutdoor, damp, explosive areas (needs special enclosure)
Operation frequencyInfrequent operation (≤12/day)Frequent duty (cranes, elevator main circuits)
  1. Application Advantages
  2. Economical: High cost-performance for budget projects
  3. Full protection: 4P design covers 3-phase + neutral for modern distribution
  4. Standard compliance: اللجنة الانتخابية المستقلة 60947-2, interchangeable with major brands
  5. تركيب مرن: Front/rear wiring + 35مم DIN السكك الحديدية
  6. Reliable: ميكانيكية 8500, كهربائي 1000 العمليات

Best Combination:

Use ABE404B-4P-400A as main breaker + LS MCBs for branch protection to form a reliable two‑stage system.

For higher performance or electronic protection, upgrade to ABS (25ال), ABH (35ال), or ABN (electronic trip) مسلسل.

السابق:

ترك الرد