This is a Schneider Electric ComPacT NSX series molded case circuit breaker (مكب) for power distribution protection. New standard order number: C25N3TM160 Obsolete old order number: LV431832 Compliant with IEC 60947‑2 and GB/T 14048.2 المعايير. Basic Rated Core Parameters Item Value Type Low‑voltage MCCB for power distribution protection Frame rating 250A Poles 3P (3 أقطاب, ...

  • تفاصيل المنتج

This is a Schneider Electric ComPacT NSX series قاطع دائرة الحالة المصبوب (مكب) for power distribution protection.

New standard order number: C25N3TM160

Obsolete old order number: LV431832

Compliant with IEC 60947‑2 and GB/T 14048.2 المعايير.

  1. Basic Rated Core Parameters
غرضقيمة
يكتبLow‑voltage MCCB for power distribution protection
Frame rating250أ
البولنديين3ص (3 أقطاب, all protected)
Rated current In160أ (continuous at 40℃)
Rated operational voltage Ue690فولت تيار متردد 50/60 هرتز, suitable for 380V/400V/415V systems
Rated insulation voltage Ui800الخامس و
Rated impulse withstand voltage Uimp8كيلو فولت
تكرار50/60هرتز
Utilization categoryType A (no short‑time delay, general distribution)
Isolation functionCertified isolating function per IEC 60947‑2
  1. Short‑Circuit Breaking Capacity
System VoltageRated ultimate shortircuit breaking capacity IcuRated service shortircuit breaking capacity Ics
415الخامس و50ال50ال (100% وحدة العناية المركزة, reusable after breaking)
500الخامس و36ال36ال
690الخامس و10ال10ال

Rated short‑time withstand current Icw (1s): 12kA at 415V AC

  1. TMD Thermal‑Magnetic Release Characteristics

Standard TMD thermal‑magnetic release, LI protection (long‑time overload + instantaneous short‑circuit).

  1. Long‑time overload thermal protection

Ir setting range: 0.7–1×In (112A–160A)

مميزة: 120–400s at 1.5×Ir; ≤15s at 6×Ir (standard inverse time)

  1. Short‑circuit instantaneous magnetic protection

Instantaneous current Ii: fixed at 1250A

Operating time: ≥20 مللي ثانية

  1. ميكانيكية & Installation Parameters
غرضقيمة
أبعاد (W×H×D)105mm × 161mm × 86mm
Standard mounting centersVertical 125mm × Horizontal 35mm
Mountingمُثَبَّت, front connected; horizontal/vertical, لا ديراتينغ
Wiring capacityUp to 70mm² copper cable / busbar
Mechanical endurance20,000 العمليات
Electrical endurance10,000 operations at 440V AC, في
Ingress protectionIP40 (body), IP54 (panel‑mounted)
Impact resistanceIK07
Net weightتقريبا. 2.4كجم
  1. Environmental & Compliance Parameters

Ambient temperature: -25℃ ~ +70℃; no derating below 40℃

ارتفاع: 0–2000m without derating

درجة التلوث: 3

Overvoltage category: II

الشهادات: سي سي سي, م, مجموعة شرق أفريقيا, Marine, إلخ.

Accessory slots: 5 standard slots for auxiliary, alarm, shunt, undervoltage release, إلخ.

  1. Expansion & التوافق

Can be fitted with Vigi earth‑leakage modules

Compatible with motor operators for remote control

Can add interlock, position indicator, padlock devices

Top/bottom feed both allowed without performance derating

Replacement & Selection Notes

  1. Old type LV431832 is discontinued; use C25N3TM160 instead.
  2. For electronic release (adjustable short delay / earth fault), upgrade to NSX250N with MicroLogic (2.2/5.0).
  3. Breaking ratings: ح (70ال), س (100ال), based on short‑circuit calculation.
  4. Competitors: ABB Tmax T2, Siemens 3VT250, suitable for cross‑brand replacement.

NSX250N‑3P‑160A Direct Replacement Solutions

Core Matching Rules (100% match required)

Frame rating: 250أ (do NOT downgrade to 160A frame)

البولنديين: 3ص

التصنيف الحالي: 160أ

كسر القدرة: ≥50kA at 415V AC

Release type: thermal‑magnetic (LI characteristic)

Mounting: fixed front connection, matching panel holes

  1. Recommended Replacements

سيناريو 1: Import Brand Direct Replacement

ABB Tmax XT3N250 TMD160/1600 FF 3P

رقم الطلب: 1SDA068266R1

Match: 100%

Frame 250A, 3ص, 160أ, TMG thermal‑magnetic

Icu=50kA, Ics=50kA at 415V AC

Identical dimensions and mounting holes

Full accessory compatibility

Application: foreign‑funded plants, export equipment, on‑site repair

Siemens 3VC250N TMA160 3P

رقم الطلب: 3VC2316‑2DA33‑0AA0

Match: 98%

Frame 250A, 3ص, 160أ, TMA thermal‑magnetic

50kA at 415V AC

Highly compatible dimensions

Application: Siemens low‑voltage systems

سيناريو 2: Domestic High‑Cost‑Performance Replacement

Changshu Switch CM3‑250H/3300 160A

Match: 99%

Frame 250A, 3ص, 160أ, distribution type thermal‑magnetic

Icu=50kA at 415V AC

Compliant with IEC 60947‑2 / GB 14048.2

Application: industrial, building distribution, domestic projects

Chint NM8‑250N/3P 160A

Match: 95%

Frame 250A, 3ص, 160أ, thermal‑magnetic

50kA at 415V AC

Application: civil construction, general distribution

  1. أبعاد & Parameters Comparison
نموذجأبعاد (W×H×D)Mounting Centersوحدة العناية المركزة (415V)ReleaseFrame
NSX250N‑3P‑160A105×161×86mm125mm×35mm50الTMD250أ
ABB XT3N250 3P 160A105×161×86mm125mm×35mm50الTMG250أ
Siemens 3VC250N 3P 160A105×160×85mm125mm×35mm50الTMA250أ
CM3‑250H 3P 160A108×162×86mm125mm×35mm50الThermal‑magnetic250أ

> ملحوظة: ABB XT3N250 matches dimensions and holes 100% – best direct replacement.

  1. Safety Rules for Replacement
  2. No frame downgrade: Do NOT use 160A frame breakers (على سبيل المثال, ABB T2N, NSX160).
  3. Breaking capacity ≥50kA: Do NOT use 36kA / 25kA models.
  4. Release matching: Use distribution‑type thermal‑magnetic only.
  5. توافق الملحقات: Match auxiliary, shunt, undervoltage, earth‑leakage modules.
  6. Final Selection Guide

Direct replacement, import, no cabinet modification: ABB XT3N250 TMD160/1600 FF 3P

New project, domestic approval, cost‑effective: Changshu CM3‑250H/3300 160A

Siemens system replacement: Siemens 3VC250N TMA160 3P