قاطع الدائرة/

قاطع الدائرة شنايدر EZ7DPN-C16 (EZ711603G)

المعلمةValueDescription
Rated Voltage230الخامس وOnly suitable for 230V systems
التصنيف الحالي16أMatches loads ≤16A
كسر القدرة4.5الMaximum breaking capacity during short circuits
Trip Characteristicالنوع ج (5-10في)Suitable for general distribution protection
عرض18مم (1ف + ن)Standard modular design
Wiring Torque1.5-3ن · مTorque screwdriver recommended
Applicable Wires2.5-4mm² copper wiresSelect based on load current

  • تفاصيل المنتج

Brand: شنايدر إلكتريك

Series: Easy 7 (Project Type/EZ7 Series)

Order Number: EZ711603G

Model: EZ7DPN 4.5kA 1P+N C16A

Pole Configuration: 1ف + ن (Phase Wire + Neutral Wire)

التصنيف الحالي: 16أ

Trip Characteristic: النوع ج (Distribution Protection Type)

كسر القدرة: 4.5ال

Rated Voltage: 230VAC

تكرار: 50/60هرتز

أبعاد: Approximately 18mm wide (standard width per pole)

Model Interpretation

EZ7: Easy 7 Series

DPN: 1P+N Structure (controls phase wire and neutral wire simultaneously)

C: Trip characteristic (Type C suitable for distribution protection)

16: Rated current of 16 amperes

G: Product series suffix identifier

الميزات الوظيفية

  1. Overload Protection: When the circuit current exceeds 16A, the قاطع الدائرة will trip within a certain time to protect wires and equipment.
  2. Short-Circuit Protection: Quickly (in milliseconds) cuts off the circuit when a short circuit occurs, with a breaking capacity of 4.5kA.
  3. Simultaneous Disconnection of Phase and Neutral Wires: Enhances electrical safety and prevents accidental electric shock.
  4. Type C Trip Characteristic: Short-circuit tripping current is 5-10 أضعاف التيار المقنن (80-160أ), suitable for conventional distribution protection.

سيناريوهات التطبيق

Residential Distribution Boxes: Protection for lighting circuits and socket circuits.

Commercial Buildings: Terminal power distribution in offices, المحلات التجارية, and other venues.

Industrial Equipment: Protection for single-phase power supply equipment.

General Distribution Systems: Terminal power distribution protection for industrial, commercial, and civil use below 400V.

Detailed Technical Specifications

المعلمةValue
تصنيف جهد التشغيل230الخامس و
Rated Current Range6/10/16/20/25/32/40أ
Trip Characteristicالنوع ج (5-10في)
كسر القدرة4.5ال
الحياة الميكانيكية≥20,000 cycles (C-O cycles)
Certificationsسي سي سي, CE, RoHS
عرض18مم (1ف + ن)

ملاحظات الاستخدام

  1. Ensure the power supply is disconnected before installation, and confirm no voltage in the circuit using professional voltage detection equipment.
  2. Only use under the rated voltage (230VAC).
  3. Ensure wiring is secure to avoid overheating caused by loose connections.
  4. Regularly inspect the circuit breaker status to ensure proper operation.

The Schneider EZ7DPN-C16 (EZ711603G) is an economical 1P+N miniature circuit breaker with reliable overload and short-circuit protection functions, suitable for single-phase distribution systems in residential, commercial, and industrial settings. The Type C trip characteristic makes it particularly suitable for protecting conventional loads such as lighting and sockets, while the 4.5kA breaking capacity is sufficient to handle short-circuit faults in general household and small commercial environments.

Installation Specifications for Schneider EZ7DPN-C16 Circuit Breaker (EZ711603G)

  1. Safety Preparation
  2. Power Disconnection: Disconnect the upstream power supply before installation, and confirm no voltage in the circuit using professional voltage detection equipment.
  3. Professional Installation: Must be installed by qualified electricians in compliance with electrical safety standards (NFPA 70E, GB 50149, إلخ.).
  4. Personal Protective Equipment (PPE): Wear insulating gloves, safety goggles, and other PPE.
  5. Installation Environment:

Dry, well-ventilated environment free of corrosive gases.

Ambient temperature: -5℃~40℃, relative humidity ≤90% (at 25℃).

Avoid vibration, high-temperature, or humid locations.

  1. خطوات التثبيت
  2. DIN Rail Installation (if not pre-installed in the distribution box)

Use a 35mm standard DIN rail, ensuring the rail levelness ≤2mm/m.

Fix the rail to the distribution box base with M4 screws, spacing ≤300mm.

The rail must be reliably grounded (connect to the distribution box grounding bar with a yellow-green grounding wire).

  1. Circuit Breaker Installation

Vertical Installation (Recommended): Handle facing upward, tilt angle not exceeding 5°.

Horizontal Installation (Special Cases): Ensure flexible operation and that the closing direction complies with markings.

Specific Operations:

  1. Align the buckle on the back of the circuit breaker with the upper edge of the DIN rail.
  2. Press the circuit breaker downward until a “انقر” sound is heard, indicating it is securely snapped into the rail.

ثالثا. مواصفات الأسلاك

  1. Wiring Principles

Top In, Bottom Out”: Upper terminals for power incoming wires, lower terminals for load outgoing wires.

Neutral on Left, Phase on Right”: When facing the front of the circuit breaker, connect the neutral wire (ن) to the left terminal and the phase wire (ل) to the right terminal.

Strict Distinction: The N pole of the 1P+N circuit breaker has no protection function; reverse connection of phase and neutral wires is strictly prohibited.

  1. Terminal Connection Steps
  2. Strip the wire insulation (approximately 10-12mm) without damaging the conductor.
  3. Insert the wire into the corresponding terminal (L for phase wire, N for neutral wire).
  4. First hand-tighten the terminal screw until the wire is secure, then tighten it to the specified torque with a torque wrench.

Terminal Markings:

ل (or unmarked): Connect to phase wire (live wire).

ن: Connect to neutral wire.

  1. Technical Parameters and Installation Requirements
المعلمةValueDescription
Rated Voltage230الخامس وOnly suitable for 230V systems
التصنيف الحالي16أMatches loads ≤16A
كسر القدرة4.5الMaximum breaking capacity during short circuits
Trip Characteristicالنوع ج (5-10في)Suitable for general distribution protection
عرض18مم (1ف + ن)Standard modular design
Wiring Torque1.5-3ن · مTorque screwdriver recommended
Applicable Wires2.5-4mm² copper wiresSelect based on load current
  1. Installation Precautions
  2. Key Prohibitions

Prohibited Inverted Installation: Upside-down installation is not allowed.

Prohibited Reverse Connection: Incorrect connection of N and L poles is forbidden; خلاف ذلك, the breaker may not trip in case of leakage.

Prohibited Neutral Wire Parallel Connection: When multiple residual current circuit breakers are installed side by side, parallel connection of outgoing neutral wires is strictly prohibited.

  1. Clearance Requirements

Horizontal distance from adjacent equipment≥200mm, vertical distance≥150mm for easy operation and maintenance.

Distance between high-voltage and low-voltage equipment in the distribution box ≥50mm to reduce interference.

  1. Wiring Points

Ensure terminal connections are secure to avoid overheating affecting protection performance.

Use a PZ-type Phillips screwdriver (recommended) to prevent thread slipping.

Do not press the wire insulation into the terminal to ensure electrical clearance.

  1. Post-Installation Inspection
  2. Insulation Test: Check circuit insulation with an insulation resistance tester (≥0.5MΩ).
  3. Function Test:

Manually close and open the breaker 3 times to confirm flexible operation.

Conduct simulated overload and short-circuit tests if conditions permit (performed by professionals).

  1. Marking: Label the circuit purpose on the breaker or distribution box for easy maintenance.

سابعا. Maintenance Recommendations

Regularly inspect the tightness of circuit breaker connections, especially after long-term use.

Keep the circuit breaker surface clean to avoid dust accumulation affecting heat dissipation.

If the breaker trips frequently, troubleshoot the fault first rather than resetting repeatedly.

The key to installing the Schneider EZ7DPN-C16 circuit breaker lies in: safe power disconnection, correct installation (vertical or horizontal), standardized wiring (“Top In, Bottom Out”; “Neutral on Left, Phase on Right”), and reliable fixation on a 35mm DIN rail with proper grounding. بعد التثبيت, perform a function test to ensure normal protection performance.

Translation Notes for Export Business:

  1. Terminology Consistency: Adopted international standard electrical terms (على سبيل المثال, “1ف + ن” retained, “trip characteristicinstead oftripping feature”) for global customer understanding.
  2. Standard References: Retained original standard codes (NFPA 70E, GB 50149) with English names for compliance verification in target markets.
  3. Unit Clarity: Specified units (على سبيل المثال, “مم²”, “ن · م”) with international symbols for technical accuracy.
  4. Practical Expressions: Used concise phrases (على سبيل المثال, “securely snapped into”, “strictly prohibited”) suitable for technical documents and customer communication.
  5. Certification Retention: Kept original certification marks (سي سي سي, CE, RoHS) to facilitate import customs clearance and product certification in overseas markets.