Technical Specifications and Selection Guide for Schneider EZSS630F3630
EZSS630F3630 is a 3P 630A Moulded Case Circuit Breaker (مكب) from Schneider Electric’s EasyPact EZS+ Series (Dunhuang Series). Its official order code is EZSS630F3630, with the full model description EZS-S630 36kA TM630D 3P3D, designed for power distribution protection.
- Model Code Explanation
| الجزء النموذجي | وصف |
| EZS | EasyPact EZS+ Series MCCB |
| س | النوع القياسي |
| 630 | Frame current 630A |
| ف | كسر فئة القدرة, 36ال (415بطالة) |
| 3 | 3 أقطاب |
| 630 | Rated current 630A |
| TM630D | Thermal‑magnetic trip unit, rated 630A, D‑curve |
- المعلمات التقنية الأساسية
| غرض | مواصفة |
| نوع المنتج | Moulded Case Circuit Breaker (مكب) |
| الجهد المقنن | 400/415VAC 50/60Hz |
| التصنيف الحالي (في) | 630أ |
| تيار الإطار (Iu) | 630أ |
| عدد البولنديين | 3P3D (3-القطب, 3‑wire protection) |
| Ultimate Breaking Capacity (وحدة العناية المركزة) | 36ال (415بطالة) |
| Service Breaking Capacity (ICS) | 36ال (100% وحدة العناية المركزة) |
| Trip Unit | Thermal‑magnetic trip (TM‑D), with long‑time overload and instantaneous short‑circuit protection |
| تصاعد | مُثَبَّت (معيار), plug‑in/withdrawable optional (with accessories) |
| اتصال | اتصال أمامي (معيار), rear/plug‑in connection optional |
| Ingress Protection | IP30 (device body) |
| Ambient Conditions | Temperature ‑5℃~+40℃, الارتفاع ≥2000 م, درجة التلوث 2/3 |
| Standards | IEC 60947‑2, غيغابايت 14048.2 |
- بيئة التطبيق
- Main Applications
Main or branch switch in low-voltage distribution systems of industrial plants, commercial buildings and large public facilities
Secondary distribution, civil construction and electromechanical markets
Protect motors, محولات, generators and other electrical equipment against overload and short-circuit damage
- المتطلبات البيئية
درجة حرارة التشغيل: -5درجه مئوية ~ +40 درجه مئوية (derating required above 40℃)
Relative humidity: ≤95%, غير التكثيف
ارتفاع: ≥2000 م (derating required above 2000m)
Installation location: Indoor, vertical mounting (inclination ≤5°)
درجة التلوث: درجة 2 (معيار), applicable to degree 3 environments (with special treatment)
- Cross-Brand Equivalent/Replacement Models
| ماركة | نموذج الاستبدال | ملاحظات |
| شنايدر | CVS630F ETS2.3 630A 3P3D (LV563505) | Upgraded electronic trip unit with LSI protection |
| شنايدر | NSX630F Micrologic 2.3 630A 3P3D (LV432876) | High‑performance flagship model, full electronic protection, communication optional |
| ايه بي بي | Tmax T6N630 TMD 630/3P | Equivalent thermal‑magnetic MCCB |
| سيمنز | 3VA6300‑6EL32‑0AA0 | 630A 3P 36kA thermal‑magnetic MCCB |
| شينت | NM1‑630S/3300 630A | Domestic alternative, 36كا كسر القدرة |
- Official Order Information
Official Order Code: EZSS630F3630
Common Accessories:
Auxiliary contact: LV429310 (1لا + 1NC)
Shunt trip: LV429410 (220بطالة)
Undervoltage release: LV429510 (220بطالة)
Plug-in base: LV429100 (for 630A)
Motor mechanism: LV420089 (24VDC)
- Complete Model List of This Series (630إطار)
| نموذج | كسر القدرة | البولنديين | التصنيف الحالي | Trip Unit |
| EZSS630E3630 | 25ال | 3ص | 630أ | TM‑D |
| EZSS630F3630 | 36ال | 3ص | 630أ | TM‑D |
| EZSS630N3630 | 50ال | 3ص | 630أ | TM‑D |
| EZSS630H3630 | 70ال | 3ص | 630أ | TM‑D |
| EZSS630F4630 | 36ال | 4ص | 630أ | TM‑D |
- Installation and Maintenance Notes
- احتياطات التثبيت
For fixed mounting, reserve sufficient operating space (handle space ≥120mm)
Tighten terminals to specified torque (recommended for copper conductors: 40N·m for M10 bolts)
Maintain spacing ≥20mm between side-by-side units for proper heat dissipation
- توصيات الصيانة
التفتيش المنتظم (at least once per year): مظهر, fasteners, operating mechanism flexibility
After short-circuit tripping, inspect contact condition and replace if necessary
Thermal-magnetic trip units are non-adjustable; replace with electronic trip models if parameter adjustment is needed
- Selection and Replacement Recommendations
- Selection Factors
System short-circuit current level (ensure Icu ≥ calculated value)
نوع التحميل (D-curve for distribution protection, motor-specific type for motor protection)
Installation space and operation method
Future expansion (reserve 10%–20% margin)
- الحلول البديلة
For more precise protection and adjustable parameters, upgrade to CVS630F ETS2.3 electronic trip model
For communication and remote monitoring, select NSX630F series with intelligent trip units such as Micrologic 5.3A
For budget-limited projects, consider domestic alternatives including Chint NM1 and Delixi CDM3 series
Detailed Connection Methods for Schneider EZSS630F3630
The standard connection method of Schneider EZSS630F3630 (EZS-S630 36kA TM630D 3P3D) is fixed front connection, with multiple optional connection configurations as follows:
- Basic Connection Methods and Configuration Options
| نوع التركيب | Connection Direction | Supported | ملاحظات |
| مُثَبَّت (معيار) | اتصال أمامي | ✓ Standard | Main circuit cables/busbars connected from front, easy operation, good heat dissipation |
| مُثَبَّت | اتصال خلفي | ✓ Optional | Special configuration required, suitable for compact panel space |
| Plug‑in (خياري) | اتصال أمامي | ✓ Optional | Requires plug‑in base (على سبيل المثال. LV429100) for quick replacement and maintenance |
| Plug‑in | اتصال خلفي | ✗ Not supported | Plug‑in rear connection not available for EZS+ 630A |
| Withdrawable | Any direction | ✗ Not supported | Withdrawable mounting not available for EZS+ series |
- Connection Technical Details
- Terminal Types
الدائرة الرئيسية: Copper bolt terminals, suitable for cables or busbars
دائرة التحكم (with auxiliary contacts, shunt/undervoltage releases): Plug-in terminals for easy secondary wiring
- Conductor Specifications
Suitable copper conductor cross-section: Up to 185mm² cable or equivalent busbar
Terminal tightening torque: 40N·m recommended for M10 bolts to ensure reliable connection
Supported connections: Direct cable connection, busbar connection (with dedicated clamps)
- Polarity and Phase Sequence
3P3D configuration: Connect L1, L2, L3 three-phase power; no neutral (ن) مطلوب
Markings: Clear phase sequence labels (1, 2, 3 correspond to L1, L2, L3) on the breaker body
- Connection Precautions and Specifications
- التحضير قبل التثبيت
Ensure breaker is OFF, disconnect upstream power and verify voltage absence
Clean terminal surfaces and remove oxidation before connection
Select properly sized conductors to avoid overheating or improper fitting
- Wiring Standards
Maintain equal length for each phase in main circuit to avoid unbalanced stress
Route control circuit separately from main circuit to reduce electromagnetic interference
Check terminal tightness after wiring to prevent loose connections
Ensure no tools or debris inside the breaker after wiring; reinstall protective covers
- Special Environment Requirements
Vertical mounting: يجب تثبيته عموديا (inclination ≤5°) for proper arc extinction and mechanism operation
Derating: Derate accordingly when temperature >40℃ or altitude >2000م, adjust conductor size accordingly
درجة التلوث 3: Additional protection required to prevent dust and moisture from affecting insulation
- Recommended Connection Accessories
The following accessories are available for extended functions or special installations:
| ملحق | رمز الطلب | وظيفة |
| Plug‑in base | LV429100 | For 630A, enables plug‑in mounting and front connection |
| Auxiliary contact | LV429310 | Provides 1NO+1NC signals for status indication or control |
| Shunt trip | LV429410 | Remote tripping at 220VAC, requires control power |
| Undervoltage release | LV429510 | Undervoltage protection at 220VAC, trips on power loss |
| Busbar clamps | Dedicated | Secure busbar fixation for reliable connection |
- Selection and Application Advice
- Standard Configuration: Fixed front connection preferred for general distribution, balancing cost and practicality
- راحة الصيانة: Plug-in front connection recommended for frequent maintenance, reducing downtime
- Space Restrictions: Fixed rear connection can be used for limited cabinet depth, with sufficient operating space reserved
- Control Expansion: Reserve control wiring space and use suitable secondary accessories for remote control or monitoring
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية






















NH42-63-318x560.png)