ويشات: +86-13184948252 واتس اب: 0086-13811255435 بريد إلكتروني: كينت@bestcontactor.com

عن اتصال |

Schneider LC1G475KUEC 3‑Pole Contactor - المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية

قواطع/

Schneider LC1G475KUEC 3‑Pole Contactor

3‑pole contactor from domestic TeSys Giga series, AC‑3 475A/440V, coil 100–250V AC/DC wide voltage, standard 1NO+1NC auxiliary contacts. Suitable for high‑power motor control and power switching. Supports contact wear diagnosis and can be used with LR9G series thermal relays. 1 المعلمات الأساسية & Naming Explanation Item Specification Description Model LC1G475KUEC Domestic TeSys Giga series, 3ص(3لا), ...

  • تفاصيل المنتج

3‑pole contactor from domestic TeSys Giga series, AC‑3 475A/440V, coil 100–250V AC/DC wide voltage, standard 1NO+1NC auxiliary contacts. Suitable for high‑power motor control and power switching. Supports contact wear diagnosis and can be used with LR9G series thermal relays.

1 المعلمات الأساسية & Naming Explanation

غرضمواصفةوصف
نموذجLC1G475KUECDomestic TeSys Giga series, 3ص(3لا), AC‑3 ≤440V 475A, 100–250V AC/DC coil
مسلسلTeSys Giga (LC1G)New generation high‑power contactor from Schneider, replaces old LC1D475
البولنديين3ص(3لا)3‑pole normally open, for three‑phase circuit control
التصنيف الحالي475أ (AC‑3, ≤440V)Rated operational current of main circuit
Coil voltage100–250V AC/DCWide‑voltage design, compatible with various control supplies
Coil frequency50/60هرتزCompatible with global mains frequencies
اتصالات مساعدة1NO+1NCStandard configuration, expandable with more aux contacts
Applicable standardsIEC 60947‑4‑1, جيجابايت/ت 14048.4Complies with international and national standards
VersionChina version (suffix C)Designed for domestic market; no UL certification; global version without C

2 Key Performance Data

Utilization categoryRated power (400V)Rated power (440V)Short‑time withstand current
AC‑3 (normal motor starting/running)تقريبا. 250كيلوواطتقريبا. 265كيلوواط10500أ (1s)
AC‑4 (frequent starting/reversing)تقريبا. 180كيلوواطتقريبا. 190كيلوواط-
AC‑1 (حمل مقاوم)تقريبا. 475كيلوواطتقريبا. 475كيلوواط-

3 Applications & سمات

Applications

Direct starting, forward/reverse control, star‑delta starting of high‑power three‑phase asynchronous motors

Industrial power switching and distribution system control

Inductive load control with power factor ≥ 0.95

Heavy‑duty industries: building electrical, علم المعادن, chemical, mining, إلخ.

Key Features

  1. High performance: Up to 620A at AC‑3, 1050A at AC‑1 for heavy‑duty applications
  2. Smart diagnosis: Built‑in contact wear detection for predictive maintenance
  3. Wide‑voltage coil: 100–250V AC/DC reduces spare parts inventory
  4. تصميم وحدات: Supports various accessories (aux contacts, mechanical interlock, surge suppressor, إلخ.)
  5. Safe & reliable: Excellent arc extinguishing, مناسبة للبيئات الصناعية القاسية

4 Mounting & Wiring Information

Mounting dimensions (China version LC1G475C)

عرض: تقريبا. 140مم

Height: تقريبا. 270مم

Depth: تقريبا. 150مم

Mounting: Standard 35mm DIN rail or screw mounting

وزن: تقريبا. 10.6كجم

Wiring requirements

  1. محطات الدائرة الرئيسية: Suitable for copper/aluminum cables; crimping lugs recommended
  2. محطات دائرة التحكم: Suitable for 1.5–2.5mm² control cables
  3. Clearance: ≥50mm left & right, ≥100mm top & bottom for proper heat dissipation

5 توافق الملحقات & Matching Products

Accessory typeالنموذج الموصى بهوظيفة
Thermal overload relayLR9G475Matches LC1G475KUEC, provides motor overload protection
Mechanical interlockFor LC1G seriesFor forward/reverse control; prevents simultaneous closing
Surge suppressorFor LC1G seriesProtects coil against voltage spikes
وحدة الاتصال المساعدةFor LC1G seriesExpands NO/NC contacts for complex control

6 Cross‑Brand Alternatives

ماركةReplacement modelMatch levelملحوظات
ايه بي بيAF460‑30‑11 (100–250V AC/DC)عاليRated 460A, close to 475A; verify load margin
سيمنز3RT2076‑6AP36 (100–250V AC/DC)عاليSirius series, 475أ, fully compatible
شينتCJX1‑475/22 (100–250V AC/DC)واسطةDomestic alternative; slight performance differences, cost‑effective
تشانغشو التبديلCK3‑475 (100–250V AC/DC)واسطةPremium domestic brand, high cost‑performance

7 تثبيت & Commissioning Tips

  1. Pre‑installation inspection

Verify model, rated parameters and control supply match

Check for physical damage, contact oxidation

Ensure flat mounting surface and secure rail

  1. Installation steps

DIN rail: Align to 35mm rail, press firmly until locked

تركيب المسمار: Use M6 screws, torque 8–10N·m

Wiring: Main circuit first, then control circuit; observe terminal torque

  1. التكليف & testing

No‑load test: Apply control power; check smooth operation, abnormal noise

Load test: Run under load; monitor current, coil temperature

Aux contact test: Verify NO/NC switching and contact resistance

  1. Maintenance recommendations

Regularly inspect contact wear; replace if wear >1مم

Clean arc chamber; remove dust and metal particles

Check coil insulation resistance ≥1MΩ

Retighten all terminals to avoid overheating

8 Selection Notes

  1. Select contactor according to load type (AC‑3/AC‑4/AC‑1)
  2. For motor control: Contactor rated current ≥ 1.1 × motor rated current
  3. For frequent starting/reversing (AC‑4): Derate by 20–30%
  4. For unstable control supply: Prefer wide‑voltage coil models
  5. When used with thermal relay: Ensure matching ratings

Installation Manual – Schneider Domestic TeSys LC1G475KUEC 3‑Pole Contactor

Doc No.: DOCA0189ZH‑04 (based on official Schneider TeSys Giga installation guide)

Applicable model: LC1G475KUEC (domestic TeSys Giga 3‑pole contactor)

Version: January 2023

⚠️ Safety Warnings (Must Read)

Hazard typePreventive measures
Electric shock / explosion / arc flash hazard1. Disconnect all power (main and control) before installation
2. Only qualified electricians may operate
3. Use appropriate PPE
4. Comply with electrical safety codes (على سبيل المثال, NFPA 70E)
5. Install in non‑hazardous areas (اللجنة الانتخابية المستقلة 60079)
Mechanical injury hazard1. Contactor approx. 10.6كجم; support during installation
2. Avoid finger pinching between contactor and mounting plate/rail
3. Use proper tools to prevent slipping injury
Overheating hazard1. Maintain required clearances: ≥50mm sides, ≥100mm top/bottom
2. Do not store flammables near contactor
3. Inspect cooling regularly

1 Product Overview

1.1 Product Identification

نموذج: LC1G475KUEC

مسلسل: Domestic TeSys Giga (LC1G)

البولنديين: 3ص (3لا, 3‑pole normally open)

التصنيف الحالي: AC‑3 475A (440V)

Coil voltage: 100–250V AC/DC (wide voltage)

اتصالات مساعدة: 1NO+1NC standard

Standards: IEC 60947‑4‑1, جيجابايت/ت 14048.4

Version: China version (suffix C; no UL certification)

1.2 أبعاد (Unit: مم)

Dimensionقيمة
عرض140
Height270
Depth150
Mounting hole spacing100×120 (bottom hanging + fixing holes)

2 Pre‑Installation Preparation

2.1 Tools

Phillips screwdriver (PH3)

Hex key (per fixing screw size)

Torque wrench (5–20N·m range)

Wire stripper (1.5–2.5mm² control & large main cables)

Crimping tool (for cable lugs)

Multimeter (coil resistance & insulation check)

Spirit level

2.2 مواد

Mounting plate (metal, thickness ≥3mm, flat, burr‑free)

M6 mounting screws (min. 4 pcs)

Cable lugs (for main circuit cables)

Control cable (1.5–2.5mm² copper)

Main cable (≥150mm² copper recommended)

Insulation tape / heat‑shrink tubing

Marker pen

2.3 المتطلبات البيئية

المعلمةRequirement
درجة حرارة-5°C ~ +40°C (operating); -25°C ~ +55°C (storage)
رطوبة≤95% (non‑condensing)
ارتفاع≤2000m (derate above)
درجة التلوث2 (industrial environment)
Vibration≤5.9m/s² (5–150Hz)
Inclination≤30° from vertical

2.4 فحص المنتج

  1. Check packaging and transport damage
  2. Verify model label (LC1G475KUEC)
  3. Inspect contacts for oxidation, pitting, foreign matter
  4. Manually actuate armature; check smooth operation
  5. Measure coil resistance with multimeter
  6. Test auxiliary contact switching

3 Installation Procedure (Surface Mounting)

ملحوظة: Domestic LC1G475KUEC supports surface mounting only; not for DIN rail.

3.1 Mounting Plate Drilling (خياري)

  1. Mark holes at 100×120mm
  2. Drill diameter: φ6.5mm (for M6)
  3. Deburr after drilling

3.2 Hanging & Fixing

  1. Hang: Locate bottom hanging holes onto mounting plate pins/screws
  2. Preliminary fix: Hand‑tighten top M6 screws
  3. Final fix: Torque all 4 screws to 3±0.3N·m (top‑down, diagonal)
  4. Level check: Ensure inclination ≤30°

3.3 تركيب الملحقات (Aux Contacts / التعشيق الميكانيكي)

  1. اتصالات مساعدة

Disconnect control power

Align and push into top slot until click

Verify secure locking

  1. Mechanical interlock

Keep ≥50mm between two contactors

Mount interlock on sides

Adjust to prevent simultaneous closing

Test manually

4 Wiring Procedure

4.1 Pre‑Wiring Notes

  1. Confirm all power disconnected
  2. Main cables must use proper crimp lugs
  3. Control cable strip length: ~8–10mm
  4. Sequence: Main circuit first, then control

4.2 أسلاك الدائرة الرئيسية (3ص, L1/L2/L3 → T1/T2/T3)

  1. Open main terminal cover
  2. Insert lugged cables
  3. عزم الدوران:

نحاس: 12±1N·m

Aluminum: 14±1N·m (with anti‑oxidant)

  1. Securely tighten; check by gentle pull
  2. Close terminal cover

4.3 أسلاك دائرة التحكم (Coil A1/A2, Aux NO/NC)

  1. Open control terminal cover
  2. Coil:

أ1: Control supply +/Line

A2: Control supply –/Neutral

  1. Aux contacts:

لا: 13–14 (holding, indication)

نورث كارولاينا: 21–22 (interlock, fault)

  1. Control terminal torque: 2±0.2N·m
  2. Close cover

4.4 مخطط الأسلاك

5 Mounting with Thermal Relay (LR9G475)

5.1 Direct Installation

  1. Confirm matching: LC1G475KUEC + LR9G475
  2. Align thermal relay to top slot
  3. Push down until click
  4. Check secure mounting
  5. Connect pre‑installed busbars
  6. Torque busbar screws: 8±0.8N·m

5.2 Wiring Notes

  1. Main: Power → Contactor → Thermal relay → Motor
  2. Control: Thermal relay NC (95–96) in series with contactor coil
  3. Set thermal relay current to motor rated current

6 التكليف & Testing

6.1 No‑Load Test

  1. Apply control power (main open)
  2. Check smooth closing, no abnormal noise
  3. Verify aux contact switching
  4. Check rapid opening
  5. Repeat 3–5 times

6.2 Load Test

  1. Apply main power
  2. Start motor; check current within rating
  3. Monitor coil temperature ≤60°C after 1h
  4. Check terminal temperature ≤70°C (infrared)
  5. Simulate overload; verify relay trip

6.3 Contact Wear Diagnosis (LC1G Feature)

  1. Monitor via auxiliary contacts
  2. Warning when wear >1مم
  3. Replace contactor promptly

7 Maintenance & Service

7.1 Routine Inspection (every 6 شهور)

  1. De‑energize; inspect for dirt, damage
  2. Clean arc chamber (compressed air ≤0.3MPa)
  3. Check contact resistance ≤500μΩ
  4. Check coil insulation ≥1MΩ (500V megger)
  5. Retighten terminals
  6. Test operation

7.2 Replacement Schedule

PartIntervalReplacement standard
جهات الاتصال الرئيسية1–2 yearsWear >1mm or resistance >500μΩ
Aux contacts2–3 yearsPoor switching
Coil3–5 yearsInsulation aging, weak closing
Arc chamber5 سنينDegraded performance

7.3 استكشاف الأخطاء وإصلاحها

SymptomPossible causesحل
Contactor fails to close1. No control power1. Check wiring
2. Coil fault2. Replace coil
3. Mechanical jam3. Clean & lubricate
Loud noise on closing1. Dirty iron core1. Clean surfaces
2. Broken ring2. Replace ring
3. Low coil voltage3. Check supply
Contacts overheating1. Loose terminals1. Retighten
2. Oxidized contacts2. Clean/replace contacts
3. الزائد3. Check load
Slow opening1. Fatigued spring1. Replace spring
2. Mechanical jam2. Clean mechanism
3. Residual magnetism3. Check coil

8 أمان & Environment

8.1 Safe Disposal

  1. Disconnect all power before scrapping
  2. Remove all wiring
  3. Separate metal & plastic for recycling
  4. Contacts contain silver alloy; recycle as precious metal

8.2 Environmental Compliance

RoHS compliant; free of Pb, Hg, إلخ.

Plastic housing recyclable

Dispose per local regulations

9 Appendix – Technical Data

المعلمةقيمة
Rated operational current (AC‑3, 400V)475أ
Rated power (400V, AC‑3)250كيلوواط
Short‑time withstand current (1s)10500أ
Coil voltage100–250V AC/DC
Coil powerInrush: ~200VA, Sealed: ~20W
Aux contact rated current5أ (AC‑15, 220V)
الحياة الميكانيكية10,000,000 العمليات
الحياة الكهربائية (AC‑3)1,000,000 العمليات

السابق:

ترك الرد

ترك رسالة