ويشات: +86-13184948252 واتس اب: 0086-13811255435 بريد إلكتروني: كينت@bestcontactor.com

عن اتصال |

Schneider XPSAV11113 Safety Relay - المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية

كهربائي/

Schneider XPSAV11113 Safety Relay

Schneider XPSAV11113 Safety Relay (Correction for XPSAX11113) This is a Schneider Preventa XPS AV series emergency stop safety relay, powered by 24VDC, dual-channel input, with 3NO instantaneous + 3NO timed + 3 solid-state auxiliary outputs. It complies with ISO 13849-1 Cat.4/PL eand IEC 61508 SIL 3, used for machine safety circuit monitoring and emergency stop ...

  • تفاصيل المنتج

Schneider XPSAV11113 Safety Relay (Correction for XPSAX11113)

This is a Schneider Preventa XPS AV series emergency stop safety relay, powered by 24VDC, dual-channel input, with 3NO instantaneous + 3NO timed + 3 solid-state auxiliary outputs. It complies with ISO 13849-1 Cat.4/PL eand IEC 61508 SIL 3, used for machine safety circuit monitoring and emergency stop control. XPSAX11113 is a likely input error; the correct model is XPSAV11113(suffix P for front cover version).

  1. Model Breakdown (Correct Model: XPSAV11113)
Model PartمعنىKey Description
XPSPlatform codePreventa safety automation platform for machine safety protection
AVرمز السلسلةXPS AV series, dedicated for emergency stop & safety switch monitoring, with timer function
11113Function code1=24VDC supply, 1=dual-channel input, 1=auto/monitored reset, 1=0–300s timer, 3=3NO instant + 3NO timed outputs
صOptional suffixWith front protective cover, IP rating upgraded to IP40 (basic version IP20)
31114No equivalentUser input “XPSAX11113” is likely a typo; no official model exists
  1. Core Technical Specifications (Official Standard)
غرضمواصفةApplicable Standard
Product TypeDual‑channel emergency stop safety relayاللجنة الانتخابية المستقلة 61508, ايزو 13849-1
الجهد المقنن24VDC (-15% ~ +10%)For industrial control power
Input Channels2 channels (configurable as 1/2 channels)Monitors single/dual‑channel safety switches / E‑stop buttons
Safety Outputs3NO instantaneous + 3NO timed (0–300s adjustable)Contact rated current: 2.5A@AC-15 230V
Auxiliary Outputs3 solid-state outputs (SS)For status indication or alarm
Safety LevelCat.4/PL e/SIL 3Highest level of machine safety protection
وضع إعادة الضبطAuto reset / monitored reset selectableMeets various safety circuit designs
تصاعد35مم DIN السكك الحديديةW45mm × D114mm × H99mm
Ingress ProtectionIP20 (basic) / IP40 (P‑version)For cabinet mounting
Operating Temp-25°C ~ +70°CIndustrial environment range
Thermal CurrentIth=20ATotal output current limit
  1. Series Model List (XPS AV Series)
نموذجSupply VoltageInput ChannelsOutput ConfigurationTimerوضع إعادة الضبط
XPSAV1111324VDCDual3NO instant + 3NO timed + 3SS0–300sAuto/monitored
XPSAV1111224VDCDual3NO instant + 3NC timed + 3SS0–300sAuto/monitored
XPSAV2111324VAC/DCDual3NO instant + 3NO timed + 3SS0–300sAuto/monitored
XPSAV1121324VDCDual3NO instant + 3NO timed + 3SS0–10sAuto/monitored
XPSAV1112324VDCDual3NO instant + 3NO timed + 3SS0–300sManual
  1. التطبيقات النموذجية & Selection Notes

-4.1 التطبيقات النموذجية

طلبSuitabilityتوصية
CNC machine safety circuitsCat.4/PL e meets high safety levels; timer for spindle brakingSeries with E‑stop, safety door switches, two‑hand controls
Automated line emergency stopDual‑channel prevents single‑point failure; timer for coordinated stoppingAuto reset for fast restart
Packaging machinery safetySolid-state outputs for status; timer for process sequencingUsed with safety light curtains, safety mats
Robot workstation safetySIL3 for high‑risk robot areas; dual‑channel monitors fence doorsConnected to robot controller safety inputs
Printing machinery safetyTimer for drum deceleration; protects equipment and operatorsMonitored reset to prevent misuse

-4.2 Key Selection & Usage Rules

FactorCorrect SelectionRisk of Wrong Selection
Safety LevelCat.4/PL e/SIL3 for high‑risk machinesLower levels fail risk assessment
Input ChannelsDual for critical circuits; single for auxiliarySingle channel creates single‑point failure risk
وضع إعادة الضبطAuto for production; manual for fault confirmationAuto in hazardous zones may cause unexpected start
Timer Requirement0–300s for motors, spindles requiring brakingNo timer may cause impact damage
Output TypeRelay for power; solid-state for signalsSolid-state on high current may burn out
  1. ميزات المنتج & Advantages
  2. High safety level: Cat.4/PL e/SIL3 certified
  3. Flexible configuration: Input channels, reset mode, timer adjustable
  4. Rich outputs: 3NO instant + 3NO timed + 3SS for complex circuits
  5. التشخيص: LED indicators for power, run, fault
  6. Compact: 45mm width saves cabinet space
  7. Backward compatible: XPSUAT13A3AP is official replacement, same dimensions
  8. صيانة & استكشاف الأخطاء وإصلاحها
  9. Regular inspection: Check LEDs and terminal tightness monthly
  10. اختبار الوظيفة: Simulate faults quarterly to verify safety response
  11. استكشاف الأخطاء وإصلاحها:

-Frequent alarms: Check safety input devices (E-stop, door switches)

-No output: Verify supply voltage and output fuses

-Abnormal timer: Recalibrate or replace timing module

  1. Warning: Never bridge safety inputs; this reduces safety level to Cat.0

Schneider XPSAV11113 is a high-performance emergency stop safety relay for machines requiring high safety levels.

If you entered XPSAX11113 intentionally, please provide more details for confirmation. If it was a typo, use XPSAV11113or its replacement XPSUAT13A3APto ensure compliance.

-Complete Guide to Replacement Models for Schneider XPSAV11113

Core Replacement Conclusion:

Schneider has discontinued the XPSAV series. XPSUAT13A3APis the official direct replacement.

Precise alternatives from major international brands are listed below, all meeting Cat.4/PL e/SIL3, 24VDC, dual-channel, timed output.

  1. Official Schneider Replacement (First Choice)
النموذج الأصليOfficial Replacementمعلمات المطابقة الرئيسيةملاحظات الاستبدال
XPSAV11113 / XPSAV11113PXPSUAT13A3AP24VDC, dual input, 3NO instant + 3NO timed + 3SS, Cat.4/PL e/SIL3Officially designated; fully compatible, same dimensions, minor wiring changes

-المعلمات الرئيسية (XPSUAT13A3AP)

-Supply: 24VDC (±15%)

-Input: Dual-channel (switchable to single)

-Outputs: 3NO instant + 3NO timed (0–300s) + 3SS

-Reset: Auto / monitored

-شهادة: ايزو 13849-1 Cat.4/PL e, اللجنة الانتخابية المستقلة 61508 SIL3, EN ISO 13850

-تصاعد: 35مم DIN السكك الحديدية, W45 × H99 × D114mm

-ملاحظات الاستبدال

  1. Wiring: Terminal arrangement differs slightly from XPSAV
  2. Setting: Knob + DIP switches instead of pure DIP
  3. Cover: Basic IP20; P-version IP40
  4. التوافق: Fully compatible with existing safety circuits
  5. Precision International Brand Alternatives
ماركةمسلسلنموذج الاستبدالمعلمات المطابقة الرئيسيةDifferences
سيمنز3SK3SK1122-1AB4024VDC, dual, 3NO+3NO timed+2SS, Cat.4/PL e/SIL3Timer 0–10s (extension for 300s); 1 fewer SS
ايه بي بيMSRMSR132TP-2424VDC, dual, 3NO+3NO timed+2SS, Cat.4/PL e/SIL31 fewer SS; simpler interface, better price
PilzPNOZ XPNOZ X3 24VDC24VDC, dual, 3NO+1NC+2SS, Cat.4/PL e/SIL3No internal timer (needs PNOZ X4); manual/monitored reset
اومرونG9SAG9SA-50124VDC, dual, 3NO+3NO timed+3SS, Cat.4/PL e/SIL3Fixed 1s timer; for applications without long delay
WeidmüllerPROtopPROtop 4.1p 24VDC24VDC, dual, 3NO+3NO timed+3SS, Cat.4/PL e/SIL3Timer 0–100s (special for 300s); modular
اتصال فينيكسPSRPSR-SPP-24DC/TS3/3X1/1X224VDC, dual, 3NO+3NO timed+1SS, Cat.4/PL e/SIL32 fewer SS; expandable
  1. اختيار & Implementation Guidelines

-3.1 Selection Principles

Factorتوصيةمخاطرة
Safety LevelMust be Cat.4/PL e/SIL3Fails assessment
Timer0–300s: XPSUAT13A3AP; 0–10s: 3SK1122No/insufficient timer causes mechanical damage
Outputs3NO+3NO+3SS ideal; 2SS acceptable for simpler systemsOverloading solid-state outputs
ResetAuto for production; manual for hazardous areasAuto reset risks unexpected startup
ماركةMatch existing system brandIncompatibility increases commissioning work

-3.2 Replacement Steps

  1. Assess circuit: Confirm inputs, outputs, حمولة, timer
  2. Rewire: Follow new model wiring diagram
  3. Set parameters: Reset mode, timer, input mode
  4. Test: E-stop, door switch, timer function
  5. Update docs: Revise drawings and manuals
  6. Performance Comparison
غرضSchneider XPSUAT13A3APSiemens 3SK1122-1AB40ABB MSR132TP-24Pilz PNOZ X3 24VDC
Supply24VDC24VDC24VDC24VDC
Inputs2-channel2-channel2-channel2-channel
Instant Out3لا3لا3لا3لا
Timed Out3لا (0–300s)3لا (0–10s)3لا (0–100s)None
Solid State3222
ResetAuto/monitoredAuto/manual/monitoredAuto/manualManual/monitored
مستوىCat.4/PL e/SIL3Cat.4/PL e/SIL3Cat.4/PL e/SIL3Cat.4/PL e/SIL3
سعرMid‑highمنتصفMid‑lowMid‑high
Lead Time2–4 weeks3–5 weeks2–3 weeks2–4 weeks
  1. Recommended Scenarios
  2. First choice: Schneider-dominated projects, الروبوتات, precision machines → XPSUAT13A3AP
  3. Cost-effective: Budget projects → ABB MSR132TP-24or Siemens 3SK1122-1AB40
  4. Long timer: Large motors, spindles → XPSUAT13A3AP
  5. Brand consistency: Match existing Siemens / ABB systems

The best replacement for XPSAV11113is XPSUAT13A3AP.

Alternatives from Siemens, ايه بي بي, Pilz, إلخ., all meet Cat.4/PL e/SIL3.

Select based on input/output, timer, reset mode, and brand to avoid safety risks or functional mismatch.

السابق:

ترك الرد

ترك رسالة