In the model numbers of the CHINT AC contactor CJX2 series, the meaning of the four-digit suffix is mainly related to the rated current and the configuration of auxiliary contacts, and the specific rules are as follows: Decomposition and Meanings of the Four-digit Number Take the common models CJX2-1210 and CJX2-0901 as examples: The first two digits ...

  • تفاصيل المنتج

In the model numbers of the CHINT AC contactor CJX2 series, the meaning of the four-digit suffix is mainly related to the rated current and the configuration of auxiliary contacts, and the specific rules are as follows:

  1. Decomposition and Meanings of the Four-digit Number

Take the common models CJX2-1210 and CJX2-0901 as examples:

  1. The first two digits (مثل 12, 09)

They represent the rated current of the contactor, with the unit being amperes (أ).

– على سبيل المثال:

12 indicates that the rated current is 12A (suitable for small and medium-sized loads, such as lighting and small motors);

09 indicates that the rated current is 9A (suitable for low-load scenarios).

Special instructions:

For some models, there may beroundingor approximate values. على سبيل المثال, the rated current of CJX2-1810 is 18A, but it may be marked as 17.5A in the actual product manual (it is necessary to refer to the official parameters).

If the model contains a letter (such as CJX2-1210N), “ن” usually indicates a reversible contactor, but the meaning of the four-digit number remains unchanged.

  1. The last two digits (مثل 10, 01)

They represent the quantity and type of auxiliary contacts, in the format ofnumber of normally open contacts + number of normally closed contacts”.

– على سبيل المثال:

10 يشير 1 normally open contact (لا) و 0 normally closed contacts (نورث كارولاينا);

01 يشير 0 normally open contacts and 1 normally closed contact;

22 يشير 2 normally open contacts and 2 normally closed contacts (على سبيل المثال, in CJX2-4011, the last two digits “11” indicate 1NO + 1نورث كارولاينا).

Special instructions:

For some models, the functions may be further distinguished byletter suffixes”. على سبيل المثال, “04” in CJX2-1204N indicates 0 normally open contacts and 4 normally closed contacts, but this type of model is relatively rare, and it is necessary to confirm in combination with the specific product parameters.

  1. Examples of Typical Models and Parameter Correspondences
Modelالتصنيف الحالي (أ)Configuration of Auxiliary Contactsسيناريوهات التطبيق
CJX2-091091لادوائر الإضاءة, control of small relays
CJX2-1201121نورث كارولايناMotor protection circuits (normally closed signal feedback)
CJX2-1810181لاSmall and medium-sized motors (such as below 1.5kW)
CJX2-2501251نورث كارولايناControl of industrial equipment (requiring normally closed signals)
CJX2-4011401لا + 1نورث كارولايناComplex logic control (such as star-delta starting)

ثالثا. Association between Other Key Parameters and Models

  1. عدد البولنديين (Pole)

It is usually not directly reflected in the four-digit number, and it is necessary to confirm through the model suffix or product description.

– على سبيل المثال:

CJX2-1210N 220V indicates a 3-pole (3ص) reversible contactor, suitable for three-phase motor control;

CJX2-6504N indicates a 4-pole (4ص) قواطع, used in special power distribution scenarios.

  1. الجهد لفائف

The voltage information may be included in the model, but it is necessary to judge in combination with the complete model.

– على سبيل المثال:

CJX2-1210 24V indicates that the coil voltage is 24V AC;

CJX2-1801 380V indicates that the coil voltage is 380V AC.

  1. الشهادات والمعايير

CE certification: Complies with the EN 60947-4-1 معيار (low-voltage switchgear and controlgear);

CCC certification: Models sold in China need to pass the China Compulsory Certification.

  1. اقتراحات الاختيار والاستخدام
  2. Select the Rated Current According to the Load Current

Principle: The rated current of the contactor ≥ 1.2 times the load current (considering the motor starting impact).

Example: When controlling a 10A motor, CJX2-1210 (12أ) should be selected instead of CJX2-0910 (9أ).

  1. Select the Auxiliary Contacts According to the Control Logic

Normally open contacts (لا): Used for signal output (such as start indication);

Normally closed contacts (نورث كارولاينا): Used for safety interlocking (such as emergency stop circuits).

  1. Pay Attention to Environmental and Installation Requirements

Protection level: Usually IP20 (protection against finger contact), and models with an IP55 or above protection level need to be selected for special scenarios;

طريقة التثبيت: Supports rail installation (35mm standard), which is convenient for quick replacement.

  1. Official Documents and Verification

For further confirmation, you can refer to the CHINT official website or product manuals. على سبيل المثال:

The technical parameters of CJX2-1210 clearly staterated current 12A, auxiliary contact 1NO”;

The manual of CJX2-0901 states “9أ, 1NC auxiliary contact”.

Through the above rules, users can quickly identify the core parameters of the CJX2 contactor to ensure accurate model selection.