ويشات: +86-13184948252 واتس اب: 0086-13811255435 بريد إلكتروني: كينت@bestcontactor.com

عن اتصال |

Schneider Electric Compact INS630-3 Pole Isolator - المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية

أخبارأخبار التجارة

Schneider Electric Compact INS630-3 Pole Isolator

This product is a non-automatic load break isolator from Schneider Electric’s Interpact INS series, with the official order code 31114.

It is designed for power isolation and maintenance safety in low-voltage distribution systems.

It is 3-pole, rated current 630A, rated voltage 690VAC, without short-circuit or overload protection, and is used only for isolation purposes.

  1. Model Breakdown
Model PartمعنىKey Description
CompactProduct platformSchneider compact distribution platform, suitable for limited panel space
INSرمز السلسلةInterpact INS series, non-automatic load break isolator, isolation only, no protection
630Frame / التصنيف الحاليFrame size 630A, operational current 630A (AC-22A / AC-23A)
3 PoleNumber of poles3ص (three-phase three-wire), no neutral pole, not suitable for neutral isolation in TN‑S / TT systems
31114Official order codeUnique code for standard version (black rotary handle, fixed mounting)
  1. Key Technical Specifications (Official Standard)
غرضمواصفةApplicable Standard
Product typeNon-automatic load break isolatorاللجنة الانتخابية المستقلة 60947-3, في 60947-3
الجهد المقننAC 690V, Ui 750VSuitable for 380/415/480V industrial systems
التصنيف الحالي630أ (AC-22A / AC-23A)Continuous operation ≤ 630A, recommended duty ≤ 80% (≤ 504A)
وقت قصير يتحمل التيار11.5kA/3s, 20كا / 1 ثانية, 4kA/30sWithstands short-circuit current only, no breaking capacity
Impulse withstand voltageUimp 8kVLightning and overvoltage protection
OperationManual rotary handle (black)Motor operation available (separate order)
تصاعدFixed typeFront / rear connection, 35mm DIN rail or panel mount
Ingress protectionIP20 body, IP55 with handleIndoor panels or outdoor enclosures
Mechanical endurance10,000 العملياتExceeds standard industrial requirements
  1. Series Model List (630A Frame)
نموذج (Order Code)البولنديينيكتبطلب
INS630 3P (31114)Standard isolatorIncoming, bus-coupler, equipment isolation (3-phase 3-wire)
INS630 4P (31115)Standard isolatorIsolation with neutral (3-phase 4-wire)
INS630 3P Changeover (31154)Manual changeover switchMains / generator manual switching
INS630 4P Changeover (31155)Manual changeover switch3-phase 4-wire dual power switching

Extended Current Ratings

حاضِر3P Code4P CodeBreaking Characteristics
400أ3111231113Same as INS630, current only
500أ3111631117
630أ3111431115This model
  1. Recommended Equivalent Models from Other Brands
ماركةمسلسلEquivalent ModelMatching Parametersملحوظات
إل إس إلكتريكMeta-MEC ISIS630N-3P3ص, 630أ, 690V, isolatorEconomic version
ايه بي بيOTOT630E033ص, 630أ, 690V, isolatorVisible break
سيمنز3KD3KD4630-0NE103ص, 630أ, 690V, isolatorMotor operation compatible
إيتونNZMNZM3-XT6303ص, 630أ, 690V, isolatorEnhanced interlocking
تشانغشو التبديلCM1GCM1G-630/33003ص, 630أ, 690V, isolatorDomestic high cost‑performance
  1. التطبيقات النموذجية (Isolation Only, لا حماية)
  2. النباتات الصناعية
طلبسببتوصية
Production line main isolation630A suitable for ≤315kW three-phase loadsUsed in series with NSX630N circuit breaker
Large motor circuit isolationMotors above 200kW (المشجعين, مضخات, الضواغط)Complete protection with contactor & relay
Panel bus-coupler isolationDual power supply systemsMechanical interlock recommended
  1. Commercial & Public Buildings

Office / shopping mall incomer isolation with EZD630 breakers

Secondary distribution isolation in hospitals and schools

Infrastructure partial isolation (metro, airport utilities)

  1. Special Applications

Generator outlet isolation ≤500kVA

Capacitor bank isolation ≤300kvar

Construction site temporary power isolation

  1. اختيار & Operation Guidelines
  2. Selection Rules
FactorCorrect SelectionRisk of Wrong Selection
وظيفةIsolation only; must be used with a circuit breakerNo protection, equipment burnout
البولنديين3P for IT systems; 4P for TN‑S / TTRisk of electric shock without neutral isolation
حاضِرTotal load ≤ 504A (80% duty)Overheating, reduced life
Short-circuitSystem Isc ≤ 11.5kA/3sContact welding, failure to open
  1. Safety Rules
  2. Do NOT break under load — operate only at no-load or light load
  3. Use interlocks with upstream breakers
  4. Indoor dry environment (-25°C ~ +70°C); outdoor needs IP55 enclosure
  5. Accessories: اتصالات مساعدة, motor operation, padlock attachment available
  6. Key Difference from Circuit Breaker
غرضCompact INS630 3PCompact NSX630N 3P
يكتبLoad break isolatorMolded case circuit breaker (مكب)
وظيفةIsolation onlyالزائد + حماية ماس كهربائى
كسر القدرةNone, withstand onlyIcu = 50kA @ 415V
UsageManual isolation for maintenanceAutomatic protection during operation
ConnectionInstalled after breakerMain protection device

Schneider Compact INS630-3P (order code 31114) is a dedicated isolation device for safe maintenance in LV distribution systems.

It must be used with a circuit breaker.

If you require both protection and isolation, use NSX630N.

For economic alternatives, consider LS IS630N or Changshu CM1G.

السابق:

التالي:

ترك الرد