Schneider Electric A9P52606 is a قاطع الدائرة المصغرة (MCB) of the Acti9 iC40 series, featuring 1P+N pole configuration, 6A rated current, and C-type tripping curve. It is designed for overload and short-circuit protection of conventional distribution circuits such as lighting and socket systems, with a rated breaking capacity of 6kA (IEC 60947‑2)/4.5ال (في 60898). It adopts DIN rail mounting and has an IP20 protection rating.
- تفسير النموذج
| غرض | Details |
| نموذج | A9P52606 |
| مسلسل | Acti9 iC40 |
| يكتب | قواطع دوائر مصغرة (MCB) |
| تكوين القطب | 1ف + ن (1 protective pole, N pole for switching only) |
| التصنيف الحالي | 6أ |
| منحنى التعثر | النوع ج |
| كسر القدرة | 6ال (IEC 60947‑2), 4.5ال (EN 60898‑1) |
| طريقة التركيب | DIN Rail |
| Protection Rating | IP20 |
- المعلمات التقنية الأساسية
| المعلمة | قيمة | معيار |
| تصنيف الجهد التشغيلي (إي) | 230فولت تيار متردد 50/60 هرتز | EN/IEC 60947‑2 |
| التصنيف الحالي (في) | 6أ | EN/IEC 60947‑2 |
| خاصية التعثر | النوع ج (instantaneous tripping at 5In‑10In) | EN/IEC 60898‑1 |
| Ultimate Breaking Capacity (وحدة العناية المركزة) | 6ال (230الخامس و) | EN/IEC 60947‑2 |
| Service Breaking Capacity (Icn) | 4.5ال (230الخامس و) | EN/IEC 60898‑1 |
| Rated Impulse Withstand Voltage (Uimp) | 4كيلو فولت | EN/IEC 60947‑2 |
| Overvoltage Category | Ⅲ | EN/IEC 60947‑2 |
| درجة التلوث | 3 | EN/IEC 60947‑2 |
| درجة حرارة التشغيل | -25درجه مئوية ~ 70 درجه مئوية | EN/IEC 60947‑2 |
| الحياة الكهربائية | 20,000 العمليات | EN/IEC 60947‑2 |
| الحياة الميكانيكية | 20,000 العمليات | EN/IEC 60947‑2 |
| أبعاد (W×D×H) | 1 module (18مم) × 44mm × 91mm | Schneider Electric Technical Manual |
| Neutral Pole Position | Left Side | Schneider Electric Technical Manual |
| Tripping Unit Type | Thermal-magnetic | Schneider Electric Technical Manual |
- الميزات الوظيفية
- 1P+N Design: Live wire protection plus synchronous neutral wire switching, suitable for single-phase distribution systems, with clear wiring and convenient maintenance.
- Type C Tripping Curve: Suitable for conventional loads such as lighting and sockets, balancing overload time-delay and short-circuit instantaneous tripping, with strong resistance to inrush current.
- High Breaking Capacity: 6ال (IEC 60947‑2)/4.5ال (EN 60898‑1), capable of handling severe short-circuit faults and ensuring distribution safety.
- Standard Mounting: DIN rail mounting with 1-module width, saving switchgear space, and compatible with Acti9 series accessories (على سبيل المثال, اتصالات مساعدة, alarm contacts).
- القدرة على التكيف البيئي: IP20 protection rating, resistant to temperatures ranging from -25℃ to 70℃, meeting the requirements of industrial and civil distribution environments.
- Application Scope
– Overload and short-circuit protection for single-phase distribution circuits of lighting, مآخذ, small motors, إلخ., in commercial buildings and industrial plants.
Places with high requirements for power supply reliability, such as office buildings, الفنادق, and hospitals.
Compatible with Acti9 series distribution boxes, used in scenarios such as terminal power distribution and branch circuit protection.
- توصيات الاختيار
- Load Matching: Type C curve is suitable for non-inductive loads (على سبيل المثال, lighting, مآخذ); avoid selecting Type D (لأحمال الطاقة) or Type B (for electronic equipment) curves.
- Circuit Matching: With a rated current of 6A, it is suitable for 1.5mm² copper core cables (long-term current-carrying capacity ≥ 10A), and the circuit length should be ≤ 100m.
- كسر القدرة: The 6kA breaking capacity is suitable for terminal distribution; the front-end should be equipped with molded case circuit breakers with higher breaking capacity (على سبيل المثال, 15kA and above).
- Accessory Selection: According to monitoring requirements, select accessories such as auxiliary contacts (على سبيل المثال, A9A26924) and alarm contacts (على سبيل المثال, A9A26934).
- استكشاف الأخطاء وإصلاحها
| ظاهرة الخلل | الأسباب المحتملة | طرق استكشاف الأخطاء وإصلاحها |
| التعثر المتكرر | الزائد, line grounding/short-circuit, mismatched tripping curve | Check load current and insulation resistance; replace MCB with a matching tripping curve |
| Failure to Close | Unreset tripping mechanism, line short-circuit, contact ablation | Manually reset the trip lever, locate the short-circuit point, replace damaged contacts |
| Excessive Temperature Rise | الأسلاك فضفاضة, contact oxidation, high ambient temperature | Tighten wiring terminals, polish contacts, improve ventilation and heat dissipation |
| Insufficient Breaking Capacity | Lack of front-end protection, excessive short-circuit current in the line | Upgrade front-end protection, select MCB with higher breaking capacity |
- الحلول البديلة
Intra-series Alternatives: A9P52610 (1ف + ن, 10أ, النوع ج), A9P52616 (1ف + ن, 16أ, النوع ج), إلخ., maintaining mounting and accessory compatibility.
Cross-series Alternatives: Schneider Electric IDPN series (على سبيل المثال, A9D18606, 1ف + ن, 6أ, النوع ج) or ABB S200 series (على سبيل المثال, S201M‑C6, 1ف + ن, 6أ, النوع ج). It is necessary to verify the matching of mounting dimensions and breaking capacity.
Complete Guide to Other Models of Schneider Electric Acti9 iC40 Series
Schneider Electric Acti9 iC40 series is a miniature circuit breaker (MCB) specially designed for single-phase/three-phase distribution systems. With 1P+N as the core product, it also provides multiple pole configurations including 2P, 3ص, 4ص, and 3P+N. The tripping curves cover Type B/C/D, and the breaking capacity is divided into standard type (4.5kA Icn/6kA Icu) and Type N (6kA Icn/10kA Icu), with rated current covering the full range of 1A~63A. The following is a structured and complete list of models:
- Model Naming Rules (A9PXXXXXX)
| موضع | Code | معنى |
| 1-2 | A9 | Acti9 Series Identifier |
| 3 | ص | Exclusive Code for iC40 Series |
| 4 | 2-4 | كسر القدرة: 2 = Standard Type (4.5kA/6kA), 4 = Type N (6كا / 10 كيلو أمبير) |
| 5 | 6/2/3/4/7 | تكوين القطب: 6 = 1P+N, 2 = 2P, 3 = 3P, 4 = 4P, 7 = 3P+N |
| 6-7 | 01~63 | التصنيف الحالي: 01 = 1A, 02 = 2A, 04 = 4A, 06 = 6A, 10 = 10A, 16 = 16A, 20 = 20A, 25 = 25A, 32 = 32A, 40 = 40A, 50 = 50A, 63 = 63A |
| Curve Identifier | – | ب/ج/د: النوع ب (3In-5In), النوع ج (5In-10In), النوع د (10In-14In) |
- Classified List of Full Series Models
- 1ف + ن (Most Commonly Used)
منحنى التعثر كسر القدرة التصنيف الحالي نموذج النوع ب Standard Type 2A/4A/6A/10A/16A/20A/25A/32A/40A A9P22602/A9P22604/A9P22606/A9P22610/A9P22616/A9P22620/A9P22625/A9P22632/A9P22640 اكتب ن 2A/4A/6A/10A/16A/20A/25A/32A/40A A9P42602/A9P42604/A9P42606/A9P42610/A9P42616/A9P42620/A9P42625/A9P42632/A9P42640 النوع ج Standard Type 2A/4A/6A/10A/16A/20A/25A/32A/40A/50A/63A A9P22602/A9P22604/A9P52606/A9P22610/A9P22616/A9P22620/A9P22625/A9P22632/A9P22640/A9P22650/A9P22663 اكتب ن 2A/4A/6A/10A/16A/20A/25A/32A/40A/50A/63A A9P42602/A9P42604/A9P54606/A9P42610/A9P42616/A9P42620/A9P42625/A9P42632/A9P42640/A9P42650/A9P42663 النوع د Standard Type 10A/16A/20A/25A/32A/40A/50A/63A A9P62610/A9P62616/A9P62620/A9P62625/A9P62632/A9P62640/A9P62650/A9P62663 اكتب ن 10A/16A/20A/25A/32A/40A/50A/63A A9P64610/A9P64616/A9P64620/A9P64625/A9P64632/A9P64640/A9P64650/A9P64663 2ص (Two-pole)
| منحنى التعثر | كسر القدرة | التصنيف الحالي | نموذج |
| النوع ج | Standard Type | 6A/10A/16A/20A/25A/32A/40A | A9P52206/A9P52210/A9P52216/A9P52220/A9P52225/A9P52232/A9P52240 |
| اكتب ن | 6A/10A/16A/20A/25A/32A/40A | A9P54206/A9P54210/A9P54216/A9P54220/A9P54225/A9P54232/A9P54240 | |
| النوع د | Standard Type | 16A/20A/32A/40A | A9P62216/A9P62220/A9P62232/A9P62240 |
| اكتب ن | 16A/20A/32A/40A | A9P64216/A9P64220/A9P64232/A9P64240 |
- 3ص (Three-pole)
| منحنى التعثر | كسر القدرة | التصنيف الحالي | نموذج |
| النوع ج | Standard Type | 6A/10A/16A/20A/25A/32A/40A | A9P52306/A9P52310/A9P52316/A9P52320/A9P52325/A9P52332/A9P52340 |
| اكتب ن | 6A/10A/16A/20A/25A/32A/40A | A9P54306/A9P54310/A9P54316/A9P54320/A9P54325/A9P54332/A9P54340 | |
| النوع د | Standard Type | 16A/20A/32A/40A/50A | A9P62316/A9P62320/A9P62332/A9P62340/A9P62350 |
| اكتب ن | 16A/20A/32A/40A/50A | A9P64316/A9P64320/A9P64332/A9P64340/A9P64350 |
- 4ص (أربعة القطب)
| منحنى التعثر | كسر القدرة | التصنيف الحالي | نموذج |
| النوع ج | Standard Type | 6A/10A/16A/20A/32A/40A | A9P52406/A9P52410/A9P52416/A9P52420/A9P52432/A9P52440 |
| اكتب ن | 6A/10A/16A/20A/32A/40A | A9P54406/A9P54410/A9P54416/A9P54420/A9P54432/A9P54440 |
- 3ف + ن (Three-pole + حيادي)
| منحنى التعثر | كسر القدرة | التصنيف الحالي | نموذج |
| النوع ج | Standard Type | 16A/20A/32A/40A | A9P52716/A9P52720/A9P52732/A9P52740 |
| اكتب ن | 16A/20A/32A/40A | A9P54716/A9P54720/A9P54732/A9P54740 | |
| النوع د | Standard Type | 20A/32A/40A | A9P62720/A9P62732/A9P62740 |
| اكتب ن | 20A/32A/40A | A9P64720/A9P64732/A9P64740 |
- Key Features and Selection Points
- Core Advantages:
1P+N Design: Live wire protection plus synchronous neutral wire switching, suitable for 230V single-phase systems, saving installation space (1 module = 18mm).
Graded Breaking Capacity: Standard type is suitable for terminal distribution, while Type N is suitable for front-end circuits close to distribution transformers.
Tripping Curve Adaptability: النوع ب (for electronic equipment), النوع ج (for lighting/sockets), النوع د (for motors/power loads).
- Comparison with the Original Model:
The model you queried: A9P52606: 1ف + ن, 6أ, النوع ج, standard breaking capacity (4.5kA/6kA).
Upgraded Type N version: A9P54606 (breaking capacity upgraded to 6kA/10kA).
Same current with different curves: A9P42606 (النوع ب), A9P62606 (النوع د).
- توافق الملحقات: The full series is compatible with Acti9 standard accessories, such as auxiliary contacts (A9A26924) and alarm contacts (A9A26934).
- سيناريوهات التطبيق النموذجية
| Model Example | Application Scenario |
| A9P52606 (1ف + ن, 6أ, النوع ج) | Residential/commercial lighting circuits, sockets for small electronic devices |
| A9P54616 (1ف + ن, 16أ, النوع ج, اكتب ن) | Kitchen appliances, air conditioner sockets (requiring higher breaking capacity) |
| A9P64232 (2ص, 32أ, النوع د, اكتب ن) | Power equipment such as single-phase water pumps and compressors |
| A9P54340 (3ص, 40أ, النوع ج, اكتب ن) | Industrial equipment such as three-phase fans and small air compressors |
المقاولين,قاطع الدائرة,العاكس للطاقة الشمسية,عداد كهرباء,البطاريات الشمسية