Siemens 7UM62 Series Multifunctional Protection Relay

Siemens 7UM62 Series Multifunctional Protection Relay

  1. Detailed Model Coding Rules for 7UM62 Series
  2. Siemens product information PDF و information on alternative brands in China

The Siemens SIPROTEC 4 7UM62 series uses a 12-digit segmented structure. The complete coding format is:

مقطع الكودوصفStandard Optionsملاحظات
7UM62سلسلة المنتجات7UM62SIPROTEC 4 multifunctional protection for generators, motors and transformers
[Function Version]Protection Function Scope11=StandardDetermines protection logic and available algorithms
12=Enhanced
13=Full (Generator‑dedicated)
[Housing Type]أبعاد & I/O Quantity1=1/2 19″, 7BI, 12BO, 1 readyDefines I/O capacity and display type
2=1/1 19″, 15BI, 20BO, 1 ready
3=Graphic display, 1/2 19″, 7BI, 12BO
[نوع المحطة]Connection TerminalB=Screw terminalB for fixed installation; E for frequent replacement
E=Plug‑in terminal (2/3‑pin)
[CT Rating]CT Ratio & SensitivityB=5A standardMatches on‑site CT for accurate measurement
E=1A standard
H=1A high‑sensitivity (IEE)
L=5A low‑sensitivity
[Region/Standard]معيار & LanguageA=Germany, 50هرتز, اللجنة الانتخابية المستقلة, GermanDefines protection curves and HMI language
B=Global, 50/60هرتز, IEC/ANSI, English (UK)
C=USA, 60هرتز, ANSI, English (US)
D=Customized
[Special Function]Additional Function0AA0=BasicSpecial functions require separate authorization
0HA0=With communication
0AC0=Enhanced event recording
0FA0=With synchrocheck
  1. Complete Model Matrix of 7UM62 Series (Grouped by Configuration)

2.1 Standard Function Version (7UM6211)

Complete ModelOrder No.Core Configurationطلب
7UM6211-1BB02-0AA07UM6211-1BB02-0AA01/2 19″, 7BI/12BO, screw, 5A CT, globalSmall/medium motor protection, general industry
7UM6211-1EB01-0HA07UM6211-1EB01-0HA01/2 19″, 7BI/12BO, plug‑in, 1A CT, with commsDistributed control systems, frequent maintenance
7UM6211-2BB02-0AA07UM6211-2BB02-0AA01/1 19″, 15BI/20BO, screw, 5A CT, globalLarge motors/transformers, complex logic
7UM6211-2EB91-0AA07UM6211-2EB91-0AA01/1 19″, 15BI/20BO, plug‑in, 1A CT, customizedCritical power equipment, custom protection
7UM6211-3BB02-0HA07UM6211-3BB02-0HA01/2 19″, graphic display, 7BI/12BO, screw, 5A CT, with commsImportant equipment with local monitoring

2.2 Enhanced Function Version (7UM6212)

Complete ModelOrder No.Core ConfigurationEnhanced Functions
7UM6212-1EB01-0AC07UM6212-1EB01-0AC01/2 19″, 7BI/12BO, plug‑in, 1A CT, event recordingFault recording, harmonic analysis
7UM6212-2BB02-0FA07UM6212-2BB02-0FA01/1 19″, 15BI/20BO, screw, 5A CT, synchrocheckGrid‑parallel operation, out‑of‑sync prevention
7UM6212-3EB01-0HA07UM6212-3EB01-0HA01/2 19″, graphic display, 7BI/12BO, plug‑in, 1A CT, with commsGraphic UI + advanced comms for smart substations

2.3 Full Function Version (7UM6213) – Generator Dedicated

Complete ModelOrder No.Core ConfigurationGenerator Protection Features
7UM6213-2EB22-0HA07UM6213-2EB22-0HA01/1 19″, 15BI/20BO, plug‑in, 1A CT, with comms100% stator earth fault, rotor earth fault protection
7UM6213-1BB02-0AA07UM6213-1BB02-0AA01/2 19″, 7BI/12BO, screw, 5A CT, globalSmall hydro & captive power generators
7UM6213-3EB91-0AC07UM6213-3EB91-0AC01/2 19″, graphic display, 7BI/12BO, plug‑in, 1A CT, event recordingGraphic fault analysis for large generators

2.4 Special Configurations (by CT & Region)

CT TypeRegion SettingTypical ModelsApplication Features
5A StandardGlobal (IEC/ANSI)7UM6211-1BB02-0AA0Most industrial power systems
7UM6211-2BB02-0AA0
1A StandardUSA (ANSI)7UM6211-1EB01-0CA0Standard for North American power systems
7UM6211-2EB01-0CA0
1A High‑SensitivityGlobal (IEC/ANSI)7UM6211-1EH01-0HA0High‑impedance earthing systems, improved earth fault detection
7UM6211-2EH01-0HA0
5A Low‑SensitivityEurope (اللجنة الانتخابية المستقلة)7UM6211-1BL02-0AA0High‑capacity equipment, reduced maloperation
7UM6211-2BL02-0AA0
  1. الوظائف الأساسية & Technical Specifications

3.1 General Technical Data

غرضقيمةوصف
Measuring Channels8×Current, 4×VoltageFull monitoring for three‑phase systems
Sampling Rate24 samples/cycleAccurate transient capture, high reliability
تواصلRS485 standard, Ethernet optionalSupports IEC 60870‑5‑103, مودبوس, إلخ.
Supply Voltage110/220V AC/DCWide‑range design
درجة الحرارة المحيطة-25درجه مئوية ~ +70 درجه مئويةIndustrial and outdoor installation
درجة الحمايةIP30For panel mounting

3.2 Core Protection Functions

Integrated comprehensive protection (varies by version):

حماية التيار الزائد (ANSI 50/51)

Impedance protection (ANSI 21)

Out-of-step protection (ANSI 78)

Over/undervoltage (ANSI 59/27)

Over/underfrequency (ANSI 81)

Stator/rotor earth fault (ANSI 64)

Reverse power (ANSI 32)

Synchrocheck (ANSI 25)

  1. اختيار & Ordering Notes
  2. Function Version

معيار (11): General motors & محولات

Enhanced (12): Advanced monitoring & event analysis

Full (13): Generator-specific, مشتمل 100% stator earth fault

  1. Housing & I/O

1/2 19″ (7BI/12BO): Space-limited panels

1/1 19″ (15BI/20BO): Complex logic, more I/O

Graphic display (3xx): Local operation & fault diagnosis

  1. CT Matching

Confirm on-site CT ratio (5A/1A)

High-sensitivity versions for high-impedance earthing

  1. Region & معيار

Global (ب): IEC/ANSI compliant, ideal for export

Regional (A/C): Optimized for local standards

  1. نماذج الاستبدال

7UM62 series is discontinued; recommended successor: 7UM85 series (SIPROTEC 5)

البدائل عبر العلامات التجارية: ABB REF615, Schneider Sepam 80 مسلسل, ABB RET670 (generator-dedicated)