ACS 310-01E-02A4-2 ABB General-Purpose Inverter

Produktübersicht & Model Explanation

ACS 310-01E-02A4-2 is a general-purpose inverter from the ABB ACS310 series with single-phase 230 V input and three-phase output. It is mainly designed for variable-torque applications such as fans and pumps, with IP20 protection and C3 EMC filter compatibility.

Model Code Breakdown (ABB ACS310 Naming Convention)

CodeBedeutungBeschreibung
ACS 310Basic seriesACS310 = general-purpose inverter, optimized for fan & pump variable-torque loads
01EFrame & enclosure01 = Frame R1; E = IP20, no built-in filter (external filter required)
02A4Rated output & Stromspannung02A = rated output current 2.4 A (0.37 kW); 4 = voltage class (200–240 V)
2Input phase2 = single-phase input (200–240 V), three-phase 200–240 V output
  1. Core Technical Specifications

2.1 Electrical Data

ArtikelSpezifikation
Input powerSingle-phase 200–240 V AC, 50/60 Hz, ±10% tolerance
OutputThree-phase 0–240 V AC, 0–500 Hz, 0.37 kW / 2.4 A, 150% overload for 60 S
Control modeU/f-Steuerung (flux vector optional), built-in PID and PFC (pump/fan control)
Digital I/O2 digital inputs, 1 relay output (250 V AC/2 A, 30 V DC/2 A)
Analog I/O1 analog input (0–10 V or 4–20 mA), 1 analog output (0–20 mA)
CommunicationBuilt-in Modbus EIA-485, Modbus RTU supported
EMCCategory C3 (industrial environment), external filter required

2.2 Mechanische Eigenschaften

ArtikelSpezifikation
FrameR1 (132 × 175 × 155 mm, W × H × D)
MontageWall or cabinet mounting, vertical installation; ≥100 mm clearance top & bottom
ProtectionIP20
TemperaturOperating: -10 °C to +40 °C (derate above 40 °C); Storage: -40 °C to +70 °C
GewichtApprox. 1.5 kg
CoolingNatural convection (no fan)
  1. Key Functions & Applications

3.1 Fan & Pump Special Functions

Built-in multi-pump control (bis zu 4 Pumps), alternation and automatic backup

Pipe cleaning and priming functions for system commissioning and maintenance

Sleep / wake-up function for significant energy saving

Anti-blockage and dry-run protection for pumps

Motor noise smoothing to reduce noise

3.2 Typische Anwendungen

AnwendungSuitable EquipmentKey Benefits
HVAC-SystemeCentrifugal fans, Pumps, cooling tower fans30–50% energy saving, stable, low noise
Water treatmentBooster pumps, submersible pumps, sewage pumpsDry-run protection, multi-pump control
Industrial circuitsCooling pumps, lubrication pumpsLonger service life, lower maintenance
Small machineryFörderer, mixers, kleine KompressorenEasy to use, kostengünstig
  1. Series Models & Alternatives

4.1 ACS310 Series (Frame R1, 200–240 V single-phase)

ModellRated PowerNennstromMain DifferenceAnwendung
ACS310-01E-02A4-20.37 kW2.4 ABasic modelSmall fans, micro pumps
ACS310-01E-04A7-20.75 kW4.7 AHigher powerSmall/medium fans & Pumps
ACS310-01E-07A5-21.5 kW7.5 AHigher powerMedium fans & Pumps
ACS310-01E-09A8-22.2 kW9.8 AHigher powerLarge fans & Pumps

4.2 Recommended Alternatives

AlternativeMain DifferenceAnwendung
ACS310-03E-02A4-4Three-phase 380–480 V input, 0.37 kWIndustrial three-phase systems
ACS355-01E-02A4-2Full-featured, built-in EMC filterHigher EMC & functional requirements
ACS580-01-03A3-4Vector control, 180% ÜberlastHigh dynamic & precision control
  1. Zubehör & Options
AccessoryType CodeBeschreibung
Control panelCDP312RBasic control and parameter setting
Advanced panelCDP312R-ETHWith Ethernet, remote monitoring
EMC filter3AFE68300909C3 EMC filter for industrial environment
Brake unitACS-BU-01For frequent start/stop and braking
I/O extension3AXD500000387624 AUS + 2 DO expansion
Comm module3AXD50000038763Profibus-DP interface
  1. Installation & Fehlerbehebung

6.1 Installationshinweise

  1. Electrical installation

Input must be protected by a circuit breaker and fuse matching 2.4 A

Output cable: shielded, max. 50 m to prevent motor overvoltage

Separate control wiring from power wiring by ≥100 mm

  1. Mechanical installation

Mount vertically with sufficient ventilation

Derate 1% per °C above 40 °C

Avoid high vibration, Staub, moisture, corrosive gas

6.2 Fault Codes

CodeBeschreibungMögliche UrsacheLösung
F001OvercurrentShort circuit, motor overload, wrong settingsCheck wiring, reduce load, reset parameters
F002OvervoltageHigh supply voltage, fast decelerationCheck supply, adjust deceleration time
F003UndervoltageLow voltage, PhasenverlustCheck input power
F004OvertemperaturePoor ventilation, blocked heatsinkImprove cooling, clean heatsink
F005Motor overloadExcess load, stallReduce load, check motor
F006Earth faultOutput grounded, motor insulation faultCheck cable and motor
  1. Auswahl & Application Advice
  2. By load type

Fan/pump variable-torque loads: ACS310 series recommended

Constant-torque loads (Förderer, mixers): ACS355 or ACS580

  1. By power

0.37 kW: ACS310-01E-02A4-2

0.37–2.2 kW: ACS310-01E series

> 2.2 kW: ACS310-03E three-phase series

  1. Energy-saving analysis

Fans and pumps can save 30–50% energy with VFD control

Use ABB DriveSize for accurate selection and energy calculation

As an entry-level model of the ABB ACS310 series, the ACS 310-01E-02A4-2 features compact design, easy operation, and fan/pump‑optimized functions, making it an ideal choice for small industrial and commercial applications. For advanced control or higher performance, upgrade to ACS355 or ACS580 series.