Core Basic Information Parameter Value Notes Model ACS580-01-106A-4 Wall-mounted general-purpose inverter Order No. 3AUA0000080503 ABB official global product code Suitable Motor Power 55 kW (75 HP) @ 400 V Standard duty / Light overload Rated Output Current 106 A Standard duty Light Overload Current 100 A Light overload (110%/60S) Heavy Duty Current 87 A Heavy ...

  • Produktdetails

Core Basic Information

ParameterWertNotizen
ModellACS580-01-106A-4Wall-mounted general-purpose inverter
Bestell-Nr.3AUA0000080503ABB official global product code
Geeignete Motorleistung55 kW (75 HP) @ 400 VStandard duty / Light overload
Rated Output Current106 AStandard duty
Light Overload Current100 ALight overload (110%/60S)
Heavy Duty Current87 AHeavy duty (150%/60S)
Power SupplyThree-phase 380–480 V ACVoltage tolerance ±10%
Input Frequency50/60 HzFrequency tolerance ±5%
MontageWall-mountedIP21 (Standard)
Gewicht28.3 kgIncluding packaging
Abmessungen203 × 732 × 295 mm (B×H×T)Excluding mounting bracket
  1. Detailed Technical Data

2.1 Elektrische Parameter

ParameterWert
Output frequency range0–500 Hz
Switching frequency2–16 kHz
SteuermodusScalar (V/f), Sensorless Vector Control (SVC)
Power factor0.98 (input)
Effizienz98.70%
Output voltage0–Input voltage
Max. output power55 kW
Digital I/O6月3日
Analog I/O2/2 (0–10 V or 4–20 mA)
CommunicationRS-485, USB
ProtectionÜberstrom, Überspannung, Unterspannung, overheat, Kurzschluss, Erdschluss, motor overtemperature, usw.

2.2 Mechanical & Environmental Parameters

ParameterWert
Protection classIP21 (Standard), IP55 optional
Betriebstemperatur-10°C bis +40°C
Storage temperature-40°C bis +70°C
Relative humidity0–95% non-condensing
VibrationIEC 60068-2-6: 10–58 Hz, 0.1 g
ShockIEC 60068-2-27: 15 g, 11 MS
KühlungForced air cooling
  1. Cross-Brand Replacement Order Numbers (55 kW, 380–480 V, Wall-mounted)
MarkeSerieModellNotizen
Schneider ElectricATV610ATV610D55N4General-purpose, eingebauter EMV-Filter
Schneider ElectricATV930ATV930D55N4High-performance, PROFINET supported
SiemensSINAMICS G1206SL3224-0BE35-5AA0Built-in filter, no braking unit
SiemensSINAMICS G1206SL3224-0BE35-5AA3Built-in filter, with braking unit
DanfossFC302FC302P55KT4E20H2XGCXXXSXXXXAXXXFor fans & Pumps
DanfossFC111FC111P55KT4E20H3BXCXXXXSXXXXAXXXGeneral-purpose
DeltaVFD-C2000VFD055C43ABuilt-in PLC
DeltaVFD-EVFD055E43AEconomy general-purpose
InnovationMD280MD280T55GCost-effective domestic alternative
InnovationMD480MD480T55GHochleistungs-Vektorregelung
INVTCHV100CHV100-055G-4Domestic general-purpose
  1. Selection Guidelines
  2. Lastabgleich

Standard duty (106 A): Fans, Pumps, variable torque loads

Light overload (100 A): Förderer, mixers, constant torque loads

Heavy duty (87 A): Compressors, cranes, impact loads

  1. Ersatzhinweise

Ensure rated current ≥ 106 A

Verify control mode (vector/SVC)

Check communication compatibility

Confirm IP rating, dimensions, cooling

  1. Optionen

Braking unit: External required for ACS580-01-106A-4

EMC filter: Recommended for low interference

Encoder interface: For closed-loop control

Complete ABB ACS580 Series Models & Order Numbers

  1. ACS580 Series Overview

ABB ACS580 is a general-purpose low-voltage AC drive series covering 0.75 kW-500 kW.

Sub-seriesTypPower RangeProtectionMontage
ACS580-01Wall-mounted0.75–250 kWIP21/IP55Wall
ACS580-04Compact module250–500 kWIP00Cabinet
ACS580-07Cabinet-built75–500 kWIP21/IP54Floor-standing
  1. ACS580-01 Series (Wall-mounted, 400V 3-phase)

2.1 Standard Models (IP21)

ModellBestell-Nr.Rated PowerNennstromMotor Power
ACS580-01-02A7-43AUA00000805110.75 kW2.7 A0.75 kW
ACS580-01-03A4-43AUA00000805121.1 kW3.4 A1.1 kW
ACS580-01-04A1-43AUA00000805131.5 kW4.1 A1.5 kW
ACS580-01-05A7-43AUA00000805142.2 kW5.7 A2.2 kW
ACS580-01-07A3-43AUA00000805153.0 kW7.3 A3.0 kW
ACS580-01-09A5-43AUA00000805164.0 kW9.5 A4.0 kW
ACS580-01-12A7-43AUA00000805175.5 kW12.7 A5.5 kW
ACS580-01-018A-43AUA00000805187.5 kW18 A7.5 kW
ACS580-01-026A-43AUA000008051911 kW26 A11 kW
ACS580-01-033A-43AUA000008052015 kW33 A15 kW
ACS580-01-039A-43AUA000008052118.5 kW39 A18.5 kW
ACS580-01-046A-43AUA000008052222 kW46 A22 kW
ACS580-01-062A-43AUA000008052330 kW62 A30 kW
ACS580-01-073A-43AUA000008052437 kW73 A37 kW
ACS580-01-096A-43AUA000020481945 kW96 A45 kW
ACS580-01-106A-43AUA000008050355 kW106 A55 kW
ACS580-01-130A-43AUA000008050475 kW130 A75 kW
ACS580-01-169A-43AUA000008050590 kW169 A90 kW
ACS580-01-180A-43AUA0000080506110 kW180 A110 kW
ACS580-01-240A-43AUA0000080507132 kW240 A132 kW
ACS580-01-293A-43AUA0000080508160 kW293 A160 kW
ACS580-01-363A-43AUA0000080509200 kW363 A200 kW
ACS580-01-430A-43AUA0000080510250 kW430 A250 kW

2.2 IP55 Versions (+B056)

ModellBestell-Nr.Beschreibung
ACS580-01-018A-4+B0563AXD500000389767.5 kW, 17 A, IP55, EMC C2
ACS580-01-026A-4+B0563AUA000008356311 kW, 25 A, IP55, EMC C2
ACS580-01-033A-4+B0563AUA000008356415 kW, 32 A, IP55, EMC C2
  1. ACS580-04 Series (Compact Module, 400V 3-phase)
ModellBestell-Nr.Rated PowerNennstromMotor Power
ACS580-04-250A-43AUA0000080530250 kW250 A250 kW
ACS580-04-310A-43AUA0000080531315 kW310 A315 kW
ACS580-04-363A-43AUA0000080532400 kW363 A400 kW
ACS580-04-430A-43AUA0000080533500 kW430 A500 kW
  1. ACS580-07 Series (Cabinet-built, 400V 3-phase)
ModellBestell-Nr.Rated PowerNennstromMotor PowerCabinet
ACS580-07-130A-43AUA000008054075 kW130 A75 kWStandard
ACS580-07-169A-43AUA000008054190 kW169 A90 kWStandard
ACS580-07-180A-43AUA0000080542110 kW180 A110 kWStandard
ACS580-07-240A-43AUA0000080543132 kW240 A132 kWStandard
ACS580-07-293A-43AUA0000080544160 kW293 A160 kWStandard
ACS580-07-363A-43AUA0000080545200 kW363 A200 kWStandard
ACS580-07-430A-43AUA0000080546250 kW430 A250 kWStandard
ACS580-07-500A-43AUA0000080547315 kW500 A315 kWGroß
  1. Modellbenennungskonvention

ACS580-XX-YYYA-Z

FieldBedeutungBeispiel
XXSeries type01=Wall, 04=Module, 07=Cabinet
YYYRated output current106 = 106 A
AUnitAmpere
ZVoltage class4=380–480V, 6=500–600V
  1. Common Options
CodeBeschreibung
0IP55, EMC filter class C2
0Bluetooth control panel
0Auxiliary control panel
0Braking unit
0PROFIBUS DP
0PROFINET
0EtherNet/IP
  1. Cross-Brand Alternatives (ACS580-01-106A-4, 55 kW/106 A)
MarkeSerieModellBestell-Nr.Notizen
SchneiderATV610ATV610D55N4150A1297General-purpose, eingebauter EMV-Filter
SchneiderATV930ATV930D55N4152A2997High-performance
SiemensSINAMICS G1206SL3224-0BE35-5AA0Standard
DanfossFC302FC302P55KT4E20H2XGCXXXSXXXXAXXX132F0021Fan/pump
DeltaVFD-C2000VFD055C43ABuilt-in PLC
InnovationMD280MD280T55GDomestic alternative