Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Schneider ICT63A Schütz - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

elektrisch/Schütz/

Schneider ICT63A Schütz

ParameterWert
ProduktserieActi9 iCT
Nennbetriebsstrom63A (AC-7a), 20A (AC-7b)
Rated Operating Voltage400V AC 50Hz
Control Voltage220~240V AC 50Hz
Bemessungsisolationsspannung500V und
Elektrisches Leben100,000 Operationen (AC-7a), 30,000 Operationen (AC-7b)
SchutzklasseIP20
Betriebstemperatur-5℃~+60℃
Montagemethode35mm DIN-Schiene
Abmessungen (W×H×D)54mm×85mm×68mm (4P Type)

  • Produktdetails

The Schneider ICT63A is a modular AC-Schütz under Schneider Electric’s Acti9 series. It has a rated current of 63A and is specifically designed for residential and similar scenarios. It is suitable for remote control of motor control, Beleuchtung, and heating equipment.

Kernparameter

ParameterWert
ProduktserieActi9 iCT
Nennbetriebsstrom63A (AC-7a), 20A (AC-7b)
Rated Operating Voltage400V AC 50Hz
Control Voltage220~240V AC 50Hz
Bemessungsisolationsspannung500V und
Elektrisches Leben100,000 Operationen (AC-7a), 30,000 Operationen (AC-7b)
SchutzklasseIP20
Betriebstemperatur-5℃~+60℃
Montagemethode35mm DIN-Schiene
Abmessungen (W×H×D)54mm×85mm×68mm (4P Type)

Notiz: AC7a is suitable for slightly inductive loads (such as lighting), and AC7b is suitable for motor loads (wie Fans). The same contactor has different rated currents for different load types.

Main Models and Differences

ModellPolzahlContact ConfigurationApplication
A9C208633P3NEIN (Normalerweise geöffnet)Three-phase motor control
A9C208644P4NEIN (Normalerweise geöffnet)Three-phase + neutral line system, lighting control
A9C208684P2NO+2NC (Normalerweise geöffnet + Normalerweise geschlossen)Control circuits requiring status feedback
A9C208674P4NC (Normalerweise geschlossen)Special control requirements, such as safety circuits

Notiz: Some models have manual operation versions (z.B., A9C21864), which are suitable for commissioning and emergency situations.

Anwendungsszenarien

  1. Residential and Commercial Appliance Control:

Air conditioning compressor control

Heating equipment such as water heaters and electric stoves

Ventilation system and fan control

  1. Lighting Systems:

Commercial lighting control

Timed/zoned control of lighting in public areas

  1. Small Motor Control:

Water pumps and compressors

Motors for rolling doors and garage doors

Small auxiliary motors in industrial equipment

Technische Merkmale

  1. Kompaktes Design:

Modular structure with a width occupying only 6 modules of 9mm (54mm)

Saves space in distribution boxes and enables easy installation

  1. Low Power Consumption:

Pullin power consumption of 53VA and holding power consumption of only 6.5VA

Energyefficient and reduces heat generation

  1. Quiet Operation:

Optimized electromagnetic system design with noise below 30dB

Suitable for residences and places requiring a quiet environment

  1. Hohe Zuverlässigkeit:

Entspricht IEC/EN 61095 Standards

Strong resistance to humidity and heat (works normally in an environment with 95% humidity and 55℃ temperature)

Electrical life of up to 100,000 Operationen (for AC7a loads)

  1. Safety Features:

Mechanical position indicator for easy status observation

IP20 protection to prevent accidental contact with live parts

Protective design for terminal blocks

Installation und Wartung

Wichtige Installationspunkte

  1. Vertikale Installation: The inclination angle should not exceed 5° to ensure good heat dissipation
  2. Electrical Connection:

Main circuit: 6~25mm² singlestrand hard wire or 6~16mm² flexible wire

Control circuit: 1.5~2.5mm² wires

Tightening torque: 3.5N·m for the main circuit and 0.8N·m for the control circuit

  1. Heat Dissipation Space: Ensure sufficient ventilation space around the contactor

Wartungsempfehlungen

Regelmäßige Inspektion:

Check if contacts are ablated or deformed

Check if connections are loose

Remove dust and foreign objects

Maintenance Cycle:

Lowfrequency use (<15 operations/hour): Inspect once a year

Highfrequency use (>15 operations/hour): Inspect every 13 months

Selection Considerations

  1. Selection Based on Load Type:

Slightly inductive loads such as lighting and heating: Select the rated current for AC7a (63A)

Motorlasten: Select the rated current for AC7b (20A)

Mixed loads: Select according to the most severe conditions

  1. Selection Based on Voltage and Pole Number:

Singlephase loads: 2P model

Threephase loads: 3P model

Threephase + neutral line system: 4P model

The control voltage must be consistent with the system (usually 220~240V AC)

  1. Selection Based on Contact Configuration:

Only need to turn on/off: Select NO (Normalerweise geöffnet) Kontakte

Need status feedback: Select NO+NC combination

Special safety control: Select NC (Normalerweise geschlossen) Kontakte

Zusammenfassung

The Schneider ICT63A Contactor is a highperformance, compact modular contactor. It is designed for residential and light commercial applications, with a rated current of 63A (AC7a) and multiple contact configuration options. It is suitable for motor control, Beleuchtung, and heating equipment. Its features of low power consumption, quiet operation, and high reliability make it an ideal choice for residential, kommerziell, and light industrial applications.

Vorher:

Nächste:

Hinterlassen Sie eine Antwort