Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Schneider IPRU40‑40KA Surge Protective Device - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

elektrisch/

Schneider IPRU40‑40KA Surge Protective Device

  IPRU40‑40KA is a Type 2 pluggable AC surge protective device (SPD) aus der Acti9-Serie von Schneider Electric. Key specifications: maximum discharge current 40 kA, nominal discharge current 20 kA, maximum continuous operating voltage 350 V AC. It uses metal oxide varistor (MOV) technology and is suitable for lightning and surge protection in power distribution networks with TT/TN‑S earthing systems. Modell ...

  • Produktdetails

 

IPRU40‑40KA is a Type 2 pluggable AC surge protective device (SPD) aus der Acti9-Serie von Schneider Electric.

Key specifications: maximum discharge current 40 kA, nominal discharge current 20 kA, maximum continuous operating voltage 350 V AC.

It uses metal oxide varistor (MOV) technology and is suitable for lightning and surge protection in power distribution networks with TT/TN‑S earthing systems.

  1. Model Explanation
CodeBedeutungBeschreibung
IPRUSeriePluggable SPD of Schneider Acti9 series, supports hot‑swap module replacement for easy maintenance
40Maximum discharge current (Imax)40 kA (8/20 μs waveform)
40DerNominal discharge current (In)20 kA (8/20 μs waveform) (Notiz: 40KA in model corresponds to In = 20 kA)
350VMaximum continuous operating voltage (Uc)350 V AC, suitable for 400 V three‑phase and 230 V single‑phase systems
PNumber of poles1P+N / 2P / 3P+N / 4P
  1. Key Technical Specifications
ArtikelWertNotiz
Protection classType 2Complies with IEC 61643‑11:2011 & EN 61643‑11:2012
Discharge currentIn = 20 kA, Imax = 40 kA (8/20 μs)Common mode (CM) & differential mode (DM)
Voltage protection level (Hoch)≤ 1.8 kV (DM), ≤ 1.4 kV (CM)Low residual voltage
Response time≤ 25 nsNanosecond‑level response
Operating voltageUe = 230/400 V AC, 50/60 HzStandard low‑voltage distribution
Max continuous voltage (Uc)350 V AC (DM), 260 V AC (CM)Stable under grid fluctuations
Ingress protectionIP40 front, IP20 terminalsIndustrial environment suitable
Betriebstemperatur‑25 °C to +60 °CWide temperature range
Montage35 mm standard DIN railCompatible with Acti9 circuit breakers
VerdrahtungMax 35 mm², recommended 16 mm² solid / 25 mm² flexibleGood conductivity & heat dissipation
AbmessungenWidth varies with poles (2P:45 mm, 3P+N:72 mm, 4P:90 mm), H85 mm, D65 mmCompact design
GewichtApprox. 200–450 g (depends on poles)Lightweight
Earthing systemTT / TN‑SNot suitable for TN‑C
  1. Key Advantages & Anwendungen
  2. Vorteile

Pluggable design: Hot‑swap module without power interruption

Easy maintenance: Local status indicator (grün = normal, red = fault)

High reliability: MOV technology, lange lebensdauer, strong anti‑aging

Safe design: Built‑in thermal disconnector to prevent fire risk

Strong compatibility: Fully compatible with Schneider Acti9 series

  1. Typische Anwendungen
FieldAnwendungProtected Equipment
Industrielle AutomatisierungWorkshop power, PLC cabinets, VFDsAutomation equipment, sensors
GewerbebautenOffices, malls, hotelsLifts, HVAC, security, Netzwerke
InfrastrukturRechenzentren, telecom, transportServers, Kommunikation, monitoring
New energyPV inverters, wind convertersPower electronic devices
ResidentialDistribution boards, Smart HomesHousehold appliances
  1. Gängige Modelle & Pole Configurations
Vollständiges ModellPolenBestell-Nr.Anwendung
IPRU40‑40KA 1P+N 350V1P+NA9L040200Single‑phase 2‑wire
IPRU40‑40KA 2P 350V2PA9L040300Single‑phase 3‑wire
IPRU40‑40KA 3P+N 350V3P+NA9L040600Three‑phase 4‑wire
IPRU40‑40KA 4P 350V4PA9L040400Three‑phase 4‑wire (full‑pole)
  1. Auswahl & Nutzungshinweise
  2. Coordination: Used as Type 2 protection, cooperate with Type 1 (z.B. IPR 120KA)
  3. Polauswahl: 3P+N/4P for three‑phase; 2P/1P+N for single‑phase
  4. Installation: Incoming side of main / sub‑distribution board, after circuit breaker
  5. Backup protection: Series 16–32A circuit breaker (breaking capacity ≥ 50 kA)
  6. Verdrahtung: Short and thick copper cable, length ≤ 50 cm
  7. Wartung: Check indicator regularly; replace module when red (typical 5–8 years)
  8. Difference Between IPRU40 & IPRD40
BesonderheitIPRU40IPRD40Beschreibung
Module typeBasic pluggablePluggable with remote indicationIPRD40 supports remote signal
StatusLocal LEDLocal LED + remote contact1 C/O dry contact
Bestell-Nr.A9L040xxxA9L40xxxDifferent prefix
PreisLowerHöherDue to remote function
  1. Full List of Schneider Surge Protective Devices (Acti9-Serie)
  2. Pluggable Type (iPRU / iPRD, Type 2, mainstream)
SerieModellImax / InUcPolenBestell-Nr.Notiz
iPRU (Basic)IPRU10‑10KA10 kA / 5 kA350 V1P+N/2P/3P+N/4PA9L010xxxLocal indication
IPRU20‑20KA20 kA / 10 kA350 V1P+N/2P/3P+N/4PA9L020xxxGeneral Type 2
IPRU40‑40KA40 kA / 20 kA350 V1P+N/2P/3P+N/4PA9L040xxxYour model
IPRU65‑65KA65 kA / 30 kA350 V1P+N/2P/3P+N/4PA9L065xxxHigh current
IPRU100‑100KA100 kA / 50 kA350 V3P+N/4PA9L100xxxHigh energy
iPRD (Remote)iPRD10/20/40/65Same as iPRU350 V1P+N/2P/3P+N/4PA9L40xxxWith remote dry contact
  1. Fester Typ (iST / iPR, Type 2)

iST series: iST20, iST40, iST65 (Imax 20/40/65 kA), order no. A9L916xxx

iPR series: iPR20, iPR40, iPR65 (older fixed type, gradually replaced by iPRU)

  1. Type 1 / Combined Type 1+2

iPRF1‑12.5r: Type 1, Imax = 12.5 kA (10/350 μs), 3P+N/4P, A9L012xxx

iPRD1‑15r/20r/25r: Type 1+2, Imax = 15/20/25 kA, 3P+N/4P

  1. Special Series

iPRU‑DC: For PV DC systems (500 V / 1000 V DC)

iPTU: For low‑voltage signal lines

EA9L: Easy9 economical fixed type

  1. Cross‑Brand Replacements for IPRU40‑40KA

(Type 2, Imax = 40 kA, In = 20 kA, Uc ≈ 350 V)

  1. Siemens 5SD7 Series

5SD7462‑6CN: 2P, 40 kA/20 kA, 350 V, pluggable

5SD7464‑6CN: 4P, 40 kA/20 kA, 350 V, pluggable

5SD7466‑6CN: 3P+N, 40 kA/20 kA, 350 V, pluggable

  1. ABB OVR T2 Series

OVR T2 2L 40‑320 P U: 2P, 40 kA/20 kA, 320 V

OVR T2 4L 40‑320 P U: 4P, 40 kA/20 kA, 320 V

OVR T2 3N 40‑320 P U: 3P+N, 40 kA/20 kA, 320 V

  1. Chinese Brands (Cost‑effective)

CHINT NU6‑II 40 kA/20 kA: 350 V, 1P+N/2P/3P+N/4P

DELIXI DZ47Y 40 kA/20 kA: 350 V, all poles

ZHONGLI ZL1‑40/2‑350: Type 2, 40 kA/20 kA, 350 V

III. Schneider Internal Replacements

Downsizing: IPRU20‑20KA (Imax = 20 kA), for low surge environments

Equal replacement: iPRD40‑40KA (with remote signal)

Upgrading: IPRU65‑65KA (Imax = 65 kA), higher surge protection

  1. Auswahl & Replacement Rules
  2. Match core parameters: Imax, In, Uc, Type 2, poles must be consistent
  3. Mounting compatible: 35 mm DIN rail, similar width
  4. Function difference: iPRD / 5SD7 / OVR have remote contacts; iPRU only local indication
  5. System suitable: All for TT/TN‑S, not for TN‑C

Vorher: