Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

Schneider Electric C125N420FM Molded Case Circuit Breaker - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

NachrichtHandelsnachrichten

Schneider Electric C125N420FM Molded Case Circuit Breaker

Produktübersicht & Modellaufschlüsselung

C125N420FM is a 4‑pole molded case circuit breaker from Schneider Electric’s ComPacT NS1250N series, equipped with a MicroLogic 2.0 control unit.

It is used for overload and short‑circuit protection in low‑voltage power distribution systems, widely applied in industrial plants, Gewerbebauten, and infrastructure projects.

Model SegmentBeschreibung
C125NComPacT NS1250N series, frame size 1250A, breaking capacity 50kA@415VAC
44‑pole configuration (4P)
20MicroLogic 2.0 control unit (grundlegende Schutzfunktionen)
FMFeste Halterung, manual operation, front connection
  1. Core Technical Specifications
ArtikelWertNotizen
ModellSchneider Electric C125N420FMFull description: ComPacT NS1250N 4P 1250A 50kA MIC2.0
Rahmenstrom1250AMaximum rated operational current
Polen4 Stangen (4P)3 phases + neutral protection
AuslöseeinheitMicroLogic 2.0Long‑time (L), short‑time (S), augenblicklich (ICH) Schutz
Nennstrom (Und)1250AAdjustable via trip unit
Ultimative Bruchkapazität (Icu)50kA@415VACComplies with IEC 60947‑2
MontageBehoben, front connectionSuitable for standard switchgear
BetriebHandbuchWith mechanical indication and lockability
Bemessungsisolationsspannung (Ui)1000VACIEC 60947‑2
Rated operational voltage (Ue)400/415VAC (50Hz)Standard 3‑phase voltage
Short‑time withstand current (Icw/1s)50DieEnsures system stability during faults
SchutzgradIP30Protection against solid foreign objects
Wiring capacityMax. 300mm² copperFor high‑current loads
  1. Merkmale & Vorteile
  2. Comprehensive protection

MicroLogic 2.0 provides 3‑stage protection (L‑S‑I) with adjustable settings.

Supports fault diagnostics and alarm output for easy maintenance.

  1. Efficient design

Green “T” design reduces panel wiring time by 40%.

Ergonomic operating handle for improved safety and comfort.

Modular structure supports accessories: Hilfskontakte, alarm contacts, undervoltage release, usw.

  1. Reliable performance

50kA high breaking capacity for fast fault interruption.

Mechanisches Leben: bis zu 10,000 Operationen; electrical life: bis zu 5,000 Operationen.

Umgebungstemperatur: −5°C to +40°C (full rating), −25°C to +70°C (derated).

  1. Installation & Anwendungen

4.1 Installationsanforderungen

Suitable for standard distribution boards with industry‑standard mounting depth.

Front connection for easy wiring and maintenance.

Sufficient heat dissipation space required for stable long‑term operation.

4.2 Typische Anwendungen

Incoming protection for main power distribution boards in industrial plants

Power distribution systems for large commercial complexes

UPS input/output protection in data centers

Critical load protection in infrastructure (hospitals, airports, metros)

Main protection for Motor Control Centers (MCC)

  1. Related Models & Alternativen

5.1 Derived models in the same series

ModellUnterschiedAnwendung
C125N320FM3 Stangen (3P)3‑phase loads without neutral protection
C125N450FMMicroLogic 5.0 trip unitEnergy measurement and advanced protection
C125N420PMDraw‑out installationEasy maintenance without power interruption
C125N420RMPlug‑in installationFast replacement for backup equipment

5.2 Cross‑series alternatives

ErsatzSerieMain differencePrice reference
NSX1250N 4P MIC2.0ComPacT NSXNew generation, Ausschaltvermögen 65kAApprox. +10%
Masterpact MTZ12Masterpact MTZAir circuit breaker for higher power systemsApprox. +50%

5.3 Competitive brand equivalents

MarkeErsatzRating
Siemens3WL1212‑3CB36‑4GA41250A 4P 50kA basic protection
ABBTmax T6H1250 PR221DS‑LSI 4P1250A 4P 50kA LSI protection
EatonNZM4‑1250N 4P1250A 4P 50kA basic protection
  1. Purchasing & Nutzungstipps
  2. Authentic procurement: Purchase via authorized Schneider Electric distributors or official channels to ensure quality and service.
  3. Zubehör: Optional auxiliary contacts, alarm contacts, shunt trip, undervoltage release, usw.
  4. Parametereinstellung: MicroLogic 2.0 can be programmed; adjust according to load characteristics.
  5. Wartung: Routine inspection every 1–2 years, including mechanism, Terminals, and protection functions.

> Notiz: C125N420FM complies with IEC 60947‑2, GB 14048.2 and other international & national standards. It is fully compatible with Schneider Prisma E, Blokset and other panel systems.

  1. Auswahl & Replacement Guidelines
  2. Compatibility Rules

Industrial relay sockets follow international standard dimensions and are interchangeable across brands if:

Pin count matches relay pole number

Nennstrom (≥10A) meets load

Montage (DIN-rail/screw) matches panel design

  1. Terminal Type Selection

Conventional screw: PTF08A / PTF11A / PTF14A-suitable for low-vibration environments

Finger protection: PTFZ series-suitable for areas with frequent access

Push-In Plus: PTF-PU series-ideal for mass wiring, high vibration resistance

  1. Discontinued Models

PTF08A-E / PTF14A-E are discontinued with limited stock.

Use PTFZ series as the preferred replacement.

> Notiz: PTF series sockets are rated 10A/250VAC, dielectric strength AC 2000V, operating temp −25 °C to +55 °C, suitable for 0.5–2.5 mm² copper wires.

Vorher:

Nächste:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen