Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-Mail: kent@bestcontactor.com

Um Kontakt |

SIEMENS MPCB 3RV1374-7GN10 - Schütz,Leistungsschalter,Solarwechselrichter,Stromzähler,Solarbatterien

NachrichtHandelsnachrichten

SIEMENS MPCB 3RV1374-7GN10

3RV1374-7GN10|SIEMENS SIRIUS High‑Performance Motor Protection Circuit‑Breaker (MPCB)

Vollständiges Modell: 3RV1374-7GN10 (Siemens SIRIUS 3RV1 series, moulded case circuit‑breaker with enhanced breaking capacity for starter combinations)

Marke: Siemens SIRIUS Industrial Control Series

  1. Detailed Model Breakdown
ModellteilBedeutungKey Description
3RV1SerieSIRIUS 3RV1 series, moulded case motor protection circuit‑breaker, designed with enhanced breaking capacity for starter combinations
374SizeLarge size, rated current 400A, suitable for 200kW three‑phase motors at 400V
7SchaltleistungsklasseErhöhte Bruchkapazität, up to 200kA@400V
GReisetypElectronic trip unit, short‑circuit protection adjustable from 1–10 × In
NVerbindungScrew terminals, with phase barriers for safe and reliable connection
10Anzahl der Pole3 Stangen (3P3d), for three‑phase motor protection circuits
  1. Core Technical Data
ArtikelSpezifikationNotizen
Nennbetriebsstrom (In)400A (fixed)For 200kW three‑phase induction motors at 400V
Nennspannung (Ue)690V undFor medium‑high voltage industrial motor control systems
Bemessungsisolationsspannung (Ui)1000V undHigher than operating voltage, large safety margin
Ultimate Breaking Capacity (Icu)200kA@400VEnhanced breaking capacity for heavy short‑circuit faults
Polen3 Stangen (3P3d)Standard three‑phase motor protection
Trip CharacteristicMagnetic only (short‑circuit protection only)Elektronische Reise, short‑circuit adjustable 1–10×In; must be used with overload relay
BetriebRotary ON/OFF actuatorManual control, simple and clear
MontagePanel mountingSuitable for control cabinet integration
Degree of ProtectionIP30Standard for switchgear installation
Applicable StandardIEC 60947‑4‑1International standard for motor protection devices
  1. Hauptmerkmale & Anwendungen

Main Advantages

  1. Ultra‑high breaking capacity: 200kA@400V, withstands heavy short‑circuit faults in industrial networks
  2. Precise protection: Electronic trip with adjustable short‑circuit protection for various motor starting characteristics
  3. Reliable connection: Screw terminals with phase barriers to prevent phase‑to‑phase short circuits
  4. System integration: Designed for starter combinations, works perfectly with contactors and overload relays
  5. Durable design: Industrial‑grade quality, suitable for harsh environments and long mechanical life

Typische Anwendungen

Large industrial motor control centers (MCC), 400V/690V systems

Short‑circuit protection for three‑phase induction motors up to 200kW at 400V (must be used with overload relay)

High‑power motor protection in metallurgy, Bergbau, paper and other heavy industries

Large continuous‑duty equipment: Kompressoren, Fans, Pumps

Main drive motors in production lines with frequent starting and fluctuating loads

  1. Replacement Models

Upgrades / Replacements (Same Brand)

ModellKey DataMerkmaleAnwendung
3VA2240‑0MS32‑0AA0400A, 200kA@400V, 3P, elektronische ReiseUpgrade replacement for 3RV1, new 3VA2 series MCCBNew projects requiring higher performance and communication
3RV1374‑7KN10400A, 200kA@400V, 3P, elektronische ReiseDifferent terminal configurationSame rating, different connection requirements
3RV1374‑7GN20400A, 200kA@400V, 4P, elektronische Reise4‑pole version with neutral protectionThree‑phase four‑wire systems needing neutral protection

Cross‑Brand Alternatives

MarkeModellMatching Specifications
ABBTmax T4H 400 PR221DS400A, 100kA breaking, elektronische Reise, 3P
SchneiderTeSys GV4‑ME400400A, 100kA breaking, thermal‑magnetic trip, 3P
MitsubishiNF400‑SEW400A, 100kA breaking, elektronische Reise, 3P
  1. Protection coordination: This unit provides magnetic only (short‑circuit) protection and must be used with an overload relay (z.B. 3RU series) for complete motor protection.
  2. Breaking capacity matching: Selected based on system short‑circuit calculation; 200kA suits most industrial grids.
  3. Verdrahtung: Screw terminals for copper/aluminum cables; observe cross‑section and torque specifications.
  4. Mounting space: Large frame size requires sufficient cabinet space.
  5. Upgrade recommendation: Some 3RV1 models are discontinued; 3VA2 series is recommended for new projects for advanced protection and communication.
  6. Zubehör: Hilfskontakte, alarm contacts available for motor status monitoring and control.

Vorher:

Hinterlassen Sie eine Antwort

Eine Nachricht hinterlassen