ABB ESB20-20N-06 contactor

ABB ESB20-20N-06 Technical Analysis Report This is a 2-pole, 20A, 2NO, 230V AC/DC universal coil modular installation contactor, suitable for single-phase load control in residential and industrial environments. It features silent operation, low power consumption, and integrated overvoltage protection, with a width of only 18mm and standard 35mm DIN rail mounting. Order code: 1SBE121111R0620. Modelo ...

  • Detalles del producto

ABB ESB20-20N-06 Technical Analysis Report

This is a 2-pole, 20A, 2NO, 230V AC/DC universal coil modular installation contactor, suitable for single-phase load control in residential and industrial environments. It features silent operation, low power consumption, and integrated overvoltage protection, with a width of only 18mm and standard 35mm DIN rail mounting. Order code: 1SBE121111R0620.

  1. Desglose del modelo
Segmento de modeloDescripción
ESBProduct family: ABB ESB series building / installation contactors
20Corriente nominal: 20A (AC-1 duty)
20Main contact configuration: 2 NO, 0 CAROLINA DEL NORTE
norteFamily identifier: Standard ESB..N installation contactor (vs. EN..N with manual switch)
6Código de voltaje de la bobina: 230V AC/DC universal
  1. Especificaciones principales

Electrical Data

ArtículoValorNotas
Rated operational current (AC-1)20AResistive load
Rated operational power (AC-7a, 230V)4.6kilovatiosSingle-phase motor load
Rated operational current (AC-3, 230V)9ASingle-phase motor load
Tensión nominal de aislamiento (interfaz de usuario)400VIEC compliant
Rated impulse withstand voltage (Uimp)6kVIEC compliant
voltaje de la bobina230VCA/CCUniversal, no polarity required
Coil powerInrush: ~12VA/10WLow-power, energy-saving design
Sealed: ~2VA/2W
Control circuit frequency50/60HzUniversal range

Mecánico & Environmental Data

ArtículoValorNotas
Number of poles22 circuitos principales
Contact configuration2NO + 0CAROLINA DEL NORTENo auxiliary contacts
Durabilidad mecánica1,000,000 operacionesHigh endurance
Electrical durability (AC-7a/7b)150,000 operacionesCEI 60947-4-1 compliant
Ancho18milímetrosModular, space-saving
Montaje35carril DIN mmStandard mounting
Temperatura de funcionamiento-25°C ~ +55°CWide temperature range
Storage temperature-40°C ~ +85°CHigh-reliability design
Protection degreeIP20Finger-safe, suitable for distribution boards
  1. Descripción de la función
  2. Universal coil technology: AC/DC universal coil, no AC/DC distinction, flexible installation, completely silent and vibration-free operation.
  3. Integrated overvoltage protection: Built-in overvoltage suppression in control circuit, improves system reliability and service life.
  4. Diseño modular: Only 18mm wide, fully compatible with other modular DIN rail components, ahorra espacio en el gabinete.
  5. Compatibilidad de accesorios: Supports standard accessories (contactos auxiliares, mechanical interlocks, etc.), tool-free plug-and-play installation.
  6. Safety design: Complies with EN/IEC/UL standards, provides reliable electrical isolation for personnel and equipment safety.
  7. Wide application: Suitable for controlling electric heaters, hot water systems, pump/fan motors, lighting and other single-phase loads.
  8. Recomendaciones de selección

Suitable Applications

Lighting, calefacción, ventilation control in residential and commercial buildings

Single-phase motor control (zapatillas, fans) for small industrial equipment

Noise-sensitive environments (hospitals, oficinas, homes)

Space-limited distribution boards / gabinetes de control

Selection Criteria

  1. Load type matching:

Resistive load (AC-1): Use 20A rated current directly

Motor load (AC-7a/7b): Recommended ≤9A (4.6kilovatios) at 230V single-phase

Inductive load: Derating or surge suppressor recommended

  1. Coil voltage selection:

Match control system supply (230VCA/CC)

Other voltages available: ESB20-20N-01 (24V), ESB20-20N-04 (110V)

  1. Contact configuration:

This model: 2NO, suitable for two independent circuits

For NC contacts: ESB20-02N series (2CAROLINA DEL NORTE)

For auxiliary contacts: Add auxiliary contact modules

  1. Environmental conditions:

Derate above +40°C ambient temperature

Extra protection required in humid or corrosive environments

  1. Notas de instalación

Pre-Installation

Verify model matches order, inspect for physical damage

Confirm coil voltage matches control supply

Prepare standard 35mm DIN rail and suitable terminals

Installation Procedure

Clip contactor firmly onto 35mm DIN rail

Wire main and control circuits per diagram; coil is non-polarized

Terminal torque: 2.5Nuevo Méjico (conductor: 0.5–2.5mm²)

Accessories clip directly onto top/side without tools

Seguridad

Isolate and verify voltage-free before installation

Separate main and control wiring to avoid interference

Ensure adequate ventilation to prevent overheating

Maintain ≥5mm clearance around contactor for heat dissipation

Commissioning & Mantenimiento

Check wiring before first energization

Test contactor operation for correct switching and no abnormal noise

Inspect contacts and terminal tightness regularly (at least annually)

  1. Modelos alternativos

Same-Series Alternatives

ModeloDifferenceSolicitud
ESB20-20N-0124V AC/DC coilLow-voltage control systems
ESB20-20N-04110V AC/DC coil110V control systems
ESB20-02N-062NC configurationApplications requiring normally closed contacts
EN20-20N-06With manual operatorEmergency manual control

Upgraded Alternatives

ModeloMejoraSolicitud
ESB25-20N-0625Una corriente nominalHigher load requirements
ESB40-40N-064-polo, 40AThree-phase or higher current
ABB AF seriesIndustrial contactorsHeavy-duty industrial environments

ABB ESB20-20N-06 is a compact, high-performance installation contactor. With silent operation, universal coil, low power consumption and modular design, it is an ideal solution for single-phase load control in residential and industrial applications. Proper selection, installation and maintenance ensure long-term reliable performance and safe, efficient control for electrical systems.

ABB Contactor Standard Selection Procedure

(Industrial & Building, for sales / quotation / diseño)

Using ESB (edificio) and AF/A (industrial) as examples – 8-step precise selection ready for proposals and quotations.

  1. Define Application & Product Family

Building / Residential / Distribution board: Lighting, calefacción, zapatillas, fans, small motors → ESB/EN series (silent, Carril DIN, narrow width)

Industrial / Equipment / Control cabinet: aficionados, zapatillas, compresores, motor main circuits → AF/A series (wide voltage, long life, heavy-duty)

  1. Determine Load Category (Critical for Derating)

Per IEC 60947 utilization categories:

AC-1: Cargas resistivas (calentadores, iluminación) → use rated current directly

AC-3: Squirrel-cage motor DOL (most common industrial) → motor current ≤ contactor rated current

AC-7a/7b: Building small motors, fans, pumps → use building contactor rated values

  1. Calculate Operating Current & Capacidad nominal
  2. Determine current from power / Voltaje
  3. Allow 1.1–1.25x safety margin (inrush, continuous duty)
  4. Select corresponding rated current (Es decir) from ABB catalog

Ejemplo: 230V single-phase 2kW heater ≈ 8.7A → ESB20-20N is sufficient

  1. Select Number of Poles

1PAG: Monofásico, single circuit

2PAG: Monofásico, double-pole (L+N switching, building standard)

3PAG: Three-phase motors / industrial (most common)

4PAG: Three-phase + N or double-break

  1. Select Coil Voltage & Tipo
  2. Control voltage: 24V, 110V, 230V, 400V, etc..
  3. Coil type:

Building: AC/DC universal coil (ESB series, non-polar, silent)

Industrial: Wide-range coil (AF series, stable at 85–110% Un)

  1. Define Auxiliary Contact Requirements

Built-in: From model (20=2NO, 02=2NC)

Expandable: EH series auxiliary contacts (1NO+1NC, 2NO, etc.)

Used for: Status feedback, interlocking, sequential control

  1. Ambiental & Special Requirements

Altitud >1000metro, temperatura >40°C → derate or upsize

Silent requirement (residential/office): Must use ESB silent type

Protección: IP20 normally sufficient for panel mounting

Mechanical interlock / revertir: Use dedicated interlock accessories

  1. Final Verification: Modelo + Certificaciones
  2. Confirm full model: family–current–contacts–coil

Ejemplo: ESB20-20N-06

  1. Verify certifications: CCC, CEI, RoHS
  2. Confirm mounting: 35carril DIN mm / screw mounting

Simplified Selection Mnemonic

  1. Choose family by application
  2. Choose duty by load type
  3. Calculate current with margin
  4. Confirm poles and coil voltage
  5. Add aux contacts for control
  6. Check environment and derate
  7. Verify model for final list

Anterior:

Deja una respuesta