chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Módulo Delta DVP08XP211T - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

inversor solar/eléctrico/

Módulo Delta DVP08XP211T

Model Explanation DVP: Delta standard PLC series 08: Total I/O points = 8 points XP: Digital I/O expansion module 2: I/O configuration = 4 inputs / 4 outputs 11: Supply voltage = DC24V T: Output type = Transistor output (NPN) Key Specifications Input: 4 points DC24V (sink/source compatible) Output: 4 points Transistor (NPN) Operating voltage: ...

  • Detalles del producto

Model Explanation

DVP: Delta standard PLC serie

08: Total I/O points = 8 agujas

XP: Digital I/O expansion module

2: I/O configuration = 4 inputs / 4 outputs

11: Supply voltage = DC24V

t: Output type = Transistor output (NPN)

  1. Key Specifications

Input: 4 points DC24V (sink/source compatible)

Output: 4 points Transistor (NPN)

Operating voltage: CC 24 V

Compatible main units: Delta mainstream models such as DVP-ES2, EX200, EC3

Instalación: DIN‑rail mount, terminal wiring

  1. Applications

Small automation equipment, production line I/O expansion, conveying/packaging/simple control, and other scenarios requiring a small number of digital extensions.

  1. Reemplazo / Upgrade Models

Reemplazo directo (same specs): DVP08XP211R (Relay output version)

New upgraded version: DVP08XP311T (Higher performance, fully compatible)

Delta DVP08XP211T Series & Cross‑Brand Selection Guide

  1. Other Models in the Same Series (Delta DVP XP Series)
ModeloConfiguración de E/SOutput TypeSupply VoltageCompatible Main UnitsNotas
DVP08XP211R4DI/4DORelé (2Aire acondicionado/250 VCA)CC 24 VES2/EX200/EC3 seriesSame spec, relay output version
DVP16XP211T8DI/8DOTransistor (NPN, 0.5A/24VDC)CC 24 VES2/EX200/EC3 series16-point expansion version
DVP16XP211R8DI/8DORelé (2Aire acondicionado/250 VCA)CC 24 VES2/EX200/EC3 series16-point relay version
DVP24XP200R16DI/8DORelé (2Aire acondicionado/250 VCA)AC powerES2/EX200/EC3 series24-point AC power version
DVP32XP200R24DI/8DORelé (2Aire acondicionado/250 VCA)AC powerES2/EX200/EC3 series32-point AC power version
DVP08XP311T4DI/4DOTransistor (NPN, 0.5A/24VDC)CC 24 VES3 seriesNew upgraded compatible version

Expansion Options in the Same Series

Input-only: DVP08XM211N (8DE, CC 24 V)

Output-only: DVP08XN211T (8HACER, NPN transistor), DVP08XN211R (8HACER, relé)

  1. Cross‑Brand Equivalent Models (8-point 4DI/4DO NPN transistor, CC 24 V)
MarcaEquivalent ModelSerieKey MatchingCompatibility Notes
MitsubishiFX2N-8ER-ES/ULFX2N series4DI/4DO, CC 24 VFor FX series CPUs; relay output available
MitsubishiFX3U-8ERFX3U series4DI/4DO, CC 24 V3rd‑generation upgrade, compatible with FX2N expansion
OmronCP1W-8ERCP1W series4DI/4DO, CC 24 VFor CP1H/CP1L/CP1E series
OmronNX-ID4442NX series8DE, can be combined with output modulesModular combination solution
siemensEM223-0HC22-0XA0S7-200 series4DI/4DO, DC24V/transistor (NPN)Classic model, for S7-200 CPU
siemensSM 1223-8BF23-0XB0S7-1200 series4DI/4DO, DC24V/transistor (NPN)New‑generation compact PLC expansion
SchneiderTM2DDI4DTTM2 series4DI/4DO, DC24V/transistor (NPN)For M218/M238/M241 series
SchneiderBMXDDI1602Modicon M340 seriesCan be combined for 4DI/4DOExpansion for large PLC systems
  1. Notas de selección
  2. Compatibility first: For cross‑brand replacement, confirm host interface protocol and power supply match; some brands require dedicated expansion cables.
  3. Output capacity: Transistor output is typically 0.5A per point; relay output up to 2A per point. Choose based on load.
  4. Upgrade path: Delta users are recommended to prioritize DVP08XP311T (improved performance, fully compatible with ES2 series).
  5. Cost balance: Same‑brand expansion modules usually have lower cost and better compatibility; cross‑brand replacement suits systems already using other PLC brands.

Delta DVP08XP211T Digital I/O Expansion Module – Full Datasheet

  1. Información básica
ArtículoEspecificación
Full ModelDVP08XP211T (DVP‑S series digital I/O expansion module)
Configuración de E/S4 entradas digitales + 4 salidas digitales
Output TypeTransistor (NPN sink)
Supply VoltageCC 24 V (±10%)
Compatible Main UnitsDVP-ES2/EX2/EC5/SS2/SA2/SX2/SE/SE2/ES3 series PLC
MontajeDIN‑rail mount (EN 50022), screw terminals
Tipo de terminalRemovable screw terminals
PesoAprox.. 105gramo
  1. Electrical Specifications – Digital Input
ArtículoEspecificación
Input TypeCC 24 V, sink/source compatible
Tensión nominalCC 24 V
Corriente de entradaAprox.. 5mA per point
ON Voltage≥14VDC
OFF Voltage≤5VDC
Tiempo de respuestaOFF→ON: ≤50μs, ON→OFF: ≤50μs
Max Input Frequency≤1kHz
IsolationOptocoupler isolation (input ↔ PLC system)
Surge ProtectionBuilt‑in, withstands 1.5kV transient voltage
  1. Electrical Specifications – Digital Output (NPN Transistor)
ArtículoEspecificación
Output TypeNPN sink, open collector
Tensión nominalDC5~30VDC
Rated Current per Point0.5A
Max Current per Common4A
Max Continuous Current0.5A/point, 4A/COM
Max Surge Current2A (1s)
Frecuencia de conmutación≤1kHz
Tiempo de respuestaOFF→ON: ≤10μs, ON→OFF: ≤10μs
Carga resistiva0.5A/point, 4A/COM
Carga inductiva12W. (24VCC)
Lamp Load2W. (24VCC)
IsolationOptocoupler isolation (output ↔ PLC system)
Protección contra sobrecorrienteBuilt‑in (self‑resetting)
  1. Mecánico & Environmental Specifications
ArtículoEspecificación
Dimensiones (W*H*D)35mm*90mm*75mm (standard DIN ail size)
Temperatura de funcionamiento-10C ~ +55C (nonondensing)
Temperatura de almacenamiento-25C ~ +70C
Humedad relativa5% ~ 95% (non ondensing)
Vibration Resistance5~150Hz, 1.5mm amplitude, 2 hours per 3 ejes
Shock Resistance10g acceleration, 11ms duration, 10 times per 3 ejes
Grado de protecciónIP20 (front)
CEMComplies with EN 61000-6-2 (industrial immunity), EN 61000-6-4 (industrial emission)
  1. Alambrado & Installation Details
  2. Input Wiring

4 input points (X0~X3), 1 common (COM)

Supports source (PNP) or sink (NPN) wiring

Recommended wire: 0.3~1.25mm², torque 0.5~0.8N·m

  1. Output Wiring

4 output points (Y0~Y3), 1 common (COM)

NPN sink output, external DC24V power required

Recommended wire: 0.3~2.5mm², torque 0.5~0.8N·m

  1. Conexión del módulo

Connects to main unit or other modules via right-side expansion port

Max expansion cable length: 1metro; multiple modules can be cascaded

The first DVP08XP211T module occupies 8 I/O addresses

  1. Selección & Application Tips
  2. Replacement options: Relay version DVP08XP211R; upgraded compatible version DVP08XP311T (for ES3 series)
  3. Cargar coincidencia: Transistor output suitable for 24VDC solenoid valves, indicators, motores pequeños; not for direct AC loads
  4. Expansion capacity: Single ES2 series CPU supports up to 8 DVP08XP211T modules, max 256 I/O points
  5. Seguridad: Open‑type module; must be installed in control cabinet, away from dust, moisture, and strong vibration

Anterior:

Deja una respuesta

Dejar un mensaje