chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Delta DVP16SP11T Digital I/O Expansion Module - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

medidor de electricidad/eléctrico/

Delta DVP16SP11T Digital I/O Expansion Module

DVP16SP11T is a 16‑point slim digital mixed I/O expansion module of Delta DVP‑S series, configured as 8 DE (Digital Input) + 8 HACER (Salida digital, NPN sinking transistor). It is specially designed for expanding I/O points of Delta DVP‑S series PLC main units, suitable for small automation systems with limited space, and supports high‑speed pulse ...

  • Detalles del producto

DVP16SP11T is a 16‑point slim digital mixed I/O expansion module of Delta DVP‑S series, configured as 8 DE (Digital Input) + 8 HACER (Salida digital, NPN sinking transistor).

It is specially designed for expanding I/O points of Delta DVP‑S series PLC main units, suitable for small automation systems with limited space, and supports high‑speed pulse output and counting functions.

  1. Model Explanation & Basic Positioning
Part of ModelSignificado
DVPDelta PLC product series code
16Total I/O points: 16 agujas (8 input + 8 output)
SPMixed I/O type (S = Slim, P = Mixed input/output)
11Version code, tipo estándar
tOutput type: Transistor output (NPN sinking)

Posicionamiento del producto:

Compact I/O expansion module for DVP‑S series PLC, used to expand the digital control capability of the main unit.

Especially suitable for space‑limited applications such as small mechanical equipment, líneas de producción automatizadas, and building control systems.

It can be seamlessly connected with DVP‑S series main units (DVP12SA11T, DVP16SA11T, etc.).

  1. Parámetros técnicos clave
ArtículoEspecificación
Características de entrada
Input points8 agujas (DE)
Input typeSinking / sourcing selectable (default sinking)
Rated input voltage24VCC (±10%)
Input current7mA per point (ON state)
Tiempo de respuesta1EM (estándar), configurable to 0.1ms (high‑speed mode)
Input impedanceAprox.. 3.3
Características de salida
Output points8 agujas (HACER)
Output typeTransistor (NPN sinking)
Rated output voltage24VCC (±10%)
Rated current per point0.5A (continuous), 1A (peak, 0.5s)
máx.. total current4A (all outputs active)
High‑speed pulse output2 points up to 10kHz (specific channels)
Electrical & Características físicas
Power requirement24VCC, module power consumption approx. 80mamá
Resistencia de aislamiento≥100MΩ (500VCC)
Dielectric strength2kV CA (between input/output/power, 1 min)
Temperatura de funcionamiento0℃ ~ +55℃
Storage temperature-25℃ ~ +70℃
Dimensiones25mm × 76mm × 102mm (diseño delgado, ahorra espacio en el gabinete)
Montaje35mm montaje en carril DIN estándar
  1. Características & Structural Advantages
  2. Ultra‑Slim Compact Design

Only 25mm wide, saves about 50% installation space compared with traditional modules, ideal for high‑density I/O control panels.

Gapless side‑by‑side assembly for maximum space utilization.

Clip‑on connection, no screws required, fácil instalación.

  1. Flexible I/O Configuration

8 input + 8 output mixed design to meet I/O requirements of most small control systems.

Input supports sinking/sourcing switching, compatible with NPN/PNP sensors.

Fast transistor response (≤10μs), suitable for high‑frequency switching control.

  1. High‑Speed Control Capability

2 high‑speed pulse outputs up to 10kHz for simple positioning (p.ej., stepper motor drive).

4 high‑speed counter inputs up to 20kHz for speed measurement, part counting, etc..

Supports interrupt input for fast response to external emergency signals.

  1. Reliable Electrical Performance

Enhanced anti‑interference design, complies with industrial EMC standards (EN 61000‑6‑2 / EN 61000‑6‑4).

Output short‑circuit protection to prevent module damage.

Built‑in surge suppression circuit to protect output devices from back EMF of inductive loads.

  1. Campos de aplicación
FieldAplicaciones típicasVentajas
Small MachineryPackaging machines, labeling machines, pequeñas máquinas herramientaSlim size, high‑speed I/O for precise control
Automated LinesConveyors, sorting systems, assembly stationsMixed I/O for various sensors & actuators
Automatización de edificiosLighting control, access control, climatizaciónLow power, suitable for long‑time operation
Smart AgricultureIrrigation, greenhouse control, feed processingStrong anti‑interference, adapts to harsh environments
New Energy EquipmentSmall PV inverters, energy storage systemsFast response, supports high‑frequency switching
  1. Comparison of Similar Modules in DVP‑S Series
ModeloConfiguración de E/SOutput TypeMain FeaturesSolicitud
DVP16SP11T8DE + 8HACERTransistor (NPN)16‑point mixed, high‑speed pulse outputFull control of small equipment
DVP16SP11R8DE + 8HACERRelé16‑point mixed, AC/DC compatibleContactores, solenoids, inductive loads
DVP08SP11T4DE + 4HACERTransistor (NPN)8‑point mixed, tamaño más pequeñoMicro‑equipment control
DVP08SP11R4DE + 4HACERRelé8‑point mixed, economicalSimple control circuits
DVP08SN11T0DE + 8HACERTransistor (NPN)Output only expansionAdditional output points only
DVP08SM11N8DE + 0HACERDigital InputInput only expansionAdditional input points only
  1. Conexión & Operation Notes
  2. System Connection

Connect to DVP‑S series main unit via left expansion port; arriba a 8 modules can be expanded.

Modules connected by dedicated expansion cable, no extra configuration needed.

máx.. I/O points after expansion: main unit points + expansion points (max. 128 agujas).

  1. Wiring Rules

Input wiring: 24VDC supply, COM to 0V, signal terminal to sensor signal.

Output wiring: 24VDC supply, COM to +24V, signal terminal to load negative (sinking output).

4 outputs share one COM terminal; 2 COM groups (4 points each) for grouped control.

  1. High‑Speed Function Configuration

High‑speed pulse output: Y0/Y1 up to 10kHz for stepper or servo motors.

High‑speed counter: X0–X3 up to 20kHz, 1‑phase / 2‑phase configurable.

Configured via programming software (DVPSoft), no extra hardware required.

  1. Protection Measures

Surge suppressor on input side to resist external interference.

Freewheeling diode for inductive loads to protect transistors.

Avoid output short‑circuit; max. 0.5A continuous per output.

  1. Selección & Reemplazo
  2. Selection Guidelines

Output type: Transistor for high‑frequency, low inductance; Relay for AC/DC, high power.

I/O points: Choose 8‑point or 16‑point based on controlled devices.

Space: Slim modules preferred for narrow control cabinets.

High‑speed functions: Select T‑type for pulse output or high‑speed counting.

  1. Replacement Options
RequirementRecommended ReplacementAdvantage
Relay output neededDVP16SP11RAC/DC load compatible, long contact life
Fewer I/O pointsDVP08SP11TSmaller size, lower cost
Higher pulse frequencyBuilt‑in high‑speed channels of DVP‑S main unit (up to 100kHz)Higher precision positioning
Cross‑series replacementDVP‑ES2 series expansion (DVP08SP11T‑ES2)Compatible with DVP‑ES2, richer functions
  1. Ejemplos de aplicaciones típicas
  2. Small Packaging Machine:

8 inputs (material position, product detection, safety door),

8 outputs (feeding motor, sealer, cutter, conveyor),

high‑speed pulse for feeding positioning.

  1. Automated Assembly Line:

Inputs (part position, fixture status),

Outputs (cylinders, motores, indicators),

high‑speed counting for production statistics.

  1. Building Lighting Control:

Inputs (motion sensor, light sensor, manual switch),

Outputs (lighting circuits, HVAC fans),

energy‑saving control.

Packing Specification: 1 pc/box, 10 pcs/carton

Diferencias fundamentales: Delta DVP16SP11T vs. Similar Modules

At a Glance:

Delta DVP16SP11T features ultra‑slim 25mm width, rentable, seamless compatibility with DVP‑S series.

siemens / mitsubishi / Omron excel in industrial ecosystem and high‑end functions.

Xinje focuses on cost‑effective domestic replacement.

  1. Main Competitors & Basic Comparison
ArtículoDelta DVP16SP11TSiemens S7‑200 SMART EM AT02Mitsubishi FX5U‑16EYT/ESOmron CP1W‑16ETXinje XC3‑16EYT
PosicionamientoDVP‑S slim mixed I/OS7‑200 SMART compact expansionFX5U/iQ‑F high‑performanceCP1H/CP1L general expansionXC3 domestic compact
I/O Config8DE + 8HACER16DE + 16HACER16DE + 16HACER16DE + 16HACER16DE + 16HACER
OutputTransistor NPN sinkingTransistor (sink/source selectable)Transistor (sink/source selectable)Transistor (sink/source selectable)Transistor sinking
Voltaje de entrada24VCC (±10%)24VCC24VCC24VCC24VCC
Ancho25milímetros (thinnest)aprox. 30milímetrosaprox. 28milímetrosaprox. 27milímetrosaprox. 26milímetros
Compatible CPUDVP‑S series onlyS7‑200 SMART onlyFX5U / FX3U seriesCP1H / CP1L / CP1EXC3 / XC2 series only
máx.. ExpansiónArriba a 8 módulosArriba a 8 módulosArriba a 16 módulosArriba a 8 módulosArriba a 7 módulos
Package1 pc/box, 10 pcs/carton1 pc/box1 pc/box1 pc/box1 pc/box
  1. Key Functional & Performance Differences

2.1 High‑Speed Control (Diferencia central)

ArtículoDelta DVP16SP11TSiemens EM AT02Mitsubishi FX5U‑16EYTOmron CP1W‑16ETXinje XC3‑16EYT
Salida de pulso2 points @10kHz2 points @≈2kHz4 axes @200kHz (built‑in)4 points @100kHz2 points @10kHz
High‑Speed Counter4 points @20kHz6 points @100kHz6 points @200kHz4 points @200kHz4 points @10kHz
Input Response0.1EM (high‑speed)1EM0.2EM0.1EM0.5EM
StrengthBasic high‑speed, small positioningStable, low‑speed logicUltra‑high frequency, precision positioningStrong counting, high anti‑interferenceLowest cost, basic control

2.2 Instalación & Alambrado

ArtículoDelta DVP16SP11TSiemens EM AT02Mitsubishi FX5U‑16EYTOmron CP1W‑16ETXinje XC3‑16EYT
MontajeClip‑on DIN rail, gaplessTornillo + Carril DINTerminal block, plug‑inCarril DIN + screwClip‑on DIN rail
TerminalSpring clamp, tool‑freeScrew terminalSpring clampScrew terminalSpring clamp
SpaceUltra‑compactStandard compactStandard compactStandard compactStandard compact

2.3 Software & Comunicación

ArtículoDelta DVP16SP11TSiemens EM AT02Mitsubishi FX5U‑16EYTOmron CP1W‑16ETXinje XC3‑16EYT
SoftwareDVPSoft (easy to use)TIA Portal (powerful)GX Works3 (FX compatible)CX‑Programmer (stable)XCPPro (user‑friendly)
ComunicaciónMODBUS RTU/TCP, CANopenPROFINET, MODBUS TCPCC‑Link, Ethernet/IP, MODBUSMODBUS RTU/TCP, HostLinkMODBUS RTU/TCP
EcosystemSeamless with Delta servo/HMIFull Siemens integrationPerfect with Mitsubishi servo/inverterHigh compatibility with Omron devicesGood with domestic equipment
DiagnosisBásicoComprehensiveDetailed, remote monitoringPrecise, fast fault locationBásico
  1. Application‑Based Selection Suggestions
  2. Best for Delta DVP16SP11T

Extremely limited space: 25mm ultra‑slim for compact panels.

DVP‑S series system: Direct expansion without adaptation.

Cost‑effective + basic high‑speed: 10kHz pulse / 20kHz counter for small packaging, labeling, transportadores.

Fast delivery: DVPSoft is easy to learn, short commissioning time for OEMs.

  1. Best for Siemens S7‑200 SMART EM AT02

Large/complex lines: PROFINET, full diagnosis, multi‑device coordination.

Siemens ecosystem: SOCIEDAD ANÓNIMA, servo, HMI unified.

Alta confiabilidad: Automotive, chemical, water treatment.

  1. Best for Mitsubishi FX5U‑16EYT/ES

Precision positioning: 200kHz pulse, multi‑axis interpolation for CNC, precision assembly.

Mid‑to‑high automation: Built‑in Ethernet, analog, CC‑Link.

Long‑term support: Mature FX ecosystem.

  1. Best for Omron CP1W‑16ET

Ambientes hostiles: Strong anti‑interference, dust, electromagnetic noise.

Counting & inspection: High‑speed counting for packaging, sorting.

Omron sensor/HMI system.

  1. Best for Xinje XC3‑16EYT

Reemplazo interno / tight budget: Lower cost than Delta.

Beginner development: XCPPro easy to use.

Domestic equipment matching: High cost‑performance.

  1. Cross‑Brand Replacement Notes
  2. I/O point match: Delta is 8DI+8DO; Siemens/Mitsubishi/Omron are 16DI+16DO per module. Adjust I/O layout.
  3. Output polarity: Delta is NPN sinking; others often support sink/source. Confirm COM wiring.
  4. High‑speed downgrade: If replacing from Mitsubishi/Siemens to Delta, reduce pulse/counter speed and reprogram.
  5. Comunicación: Delta uses mainly MODBUS; Siemens/Mitsubishi support industrial Ethernet. Adjust protocol settings.

Anterior:

Deja una respuesta

Dejar un mensaje