chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

Delta VFD055C43A-21-5.5kW Vector Control Inverter - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

inversor solar/eléctrico/

Delta VFD055C43A-21-5.5kW Vector Control Inverter

MarcaModeloSerie
siemens6SL3210-1KE21-3UF1 (G120C PN)SINAMICS G120C
MitsubishiFR-A840-00720-2-60FREQROL A840
YaskawaCIMR-AB4A0018FBAA1000
SchneiderATV320U75N4Altivar 320
TEJIDOACS550-01-012A-4ACS550

  • Detalles del producto

 

Model PartMeaningDetailed Explanation
VFDDelta Inverter IdentifierAbbreviation for Variable Frequency Drive, the universal prefix for Delta’s industrial automation inverters.
55Applicable Motor PowerFor 5.5kW (7.5HP) motores; this is the rated output power of the drive.
doCódigo de serieC2000/C2000+ Series – Delta high-performance general-purpose vector inverter, supporting induction motors and permanent magnet synchronous motors.
43Clase de voltaje & Phase4 = 3-phase 400V class (380~480V); 3 = 3-phase input (vs. 1 for single-phase).
AModo de control & CaracterísticasSupports Vector Control (FOC), Torque Control (TRQ), high-performance algorithm, 200% starting torque at 0.5Hz.
-21Version & ConfigurationStandard version: built-in braking unit (selected power ratings), no built-in EMC filter (external available), compliant with international standards.
  1. Core Technical Specifications (Official 2026 Data)
CategoríaArtículoValorNotas
Basic SpecsRated Power5.5kilovatios (7.5HP)For 5.5kW 3-phase induction motors
Voltaje de entrada3-phase 380~480V (+10%/-20%)47~63Hz, amplio rango de voltaje
Corriente de salida nominal12A (heavy duty) / 10.8A (light duty)Continuous operation in heavy-duty mode
Output Frequency Range0.1~600HzFor both low‑ and high‑speed applications
Control PerformanceModo de controlSensorless Vector, Closed-loop Vector, V/F ControlSwitchable closed/open loop
Starting Torque200% par nominal a 0,5 HzIdeal for heavy starting loads
Capacidad de sobrecarga150% for 60s; 200% for 3sFor shock loads
Speed Accuracy±0,5% (open-loop) / ±0.02% (closed-loop)High precision speed control
Torque Response Time≤10msFast dynamic response
HardwareGrado de protecciónIP20 (cabinet mount)Finger‑safe; clean environment recommended
CoolingForced air (removable fan)Easy maintenance, larga vida útil
Built-in FunctionsBraking unit (≤7.5kW), SOCIEDAD ANÓNIMA (5,000 pasos)High integration, fewer external parts
ComunicaciónRS-485 (Modbus RTU) estándarPROFINET/EtherNet/IP/CANopen optional
EnvironmentOperating Temp-10~40°C (derate 40~50°C)Derate 1% per °C above 40°C
Storage Temp-20~60°CAvoid moisture & corrosive gas
Humedad5~95% (non‑condensing)Suitable for industrial environments

III. Características principales & Ventajas

3.1 High‑Performance Control

Control de vectores: Precise independent torque & speed control for complex loads.

Built-in PLC: 5,000-step logic programming for simple automation, reducing external PLC dependency.

Auto energy saving: Dynamically adjusts output voltage; saves 20~50% at light load.

Motor auto-tuning: Completes matching in <10s, simplifies commissioning.

3.2 High Reliability Design

Modular structure: Hot-swappable keypad, expandable I/O and communication cards for easy maintenance.

Full protection: sobrecorriente, sobretensión, subtensión, overheat, sobrecarga, pérdida de fase, falla a tierra, etc..

Safe stop: Supports STO (Safe Torque Off), SIL 2 certified.

Wide grid tolerance: Withstands ±15% voltage fluctuation for harsh grids.

3.3 Flexible Communication & Expansión

Standard RS-485 Modbus RTU for multi-drive network control.

Optional modules: PROFINET, EtherNet/IP, PROFIBUS DP, CANopen.

Compatible with Siemens, Mitsubishi, Rockwell PLCs via standard telegrams and process objects.

Remote monitoring & diagnostics via Delta DIAStudio or TIA Portal.

  1. Applications & Consejos de selección

4.1 Recommended Applications

IndustryAplicaciones típicasCaracterísticas
General MachineryPumps, fans, compresores, mezcladoresEnergy saving, stable operation, longer equipment life
Manejo de materialesConveyors, grúas, hoists, máquinas de embalajeHigh precision speed control, heavy start, quick stop
Metal ProcessingLathes, milling, grinding, punching machinesHigh response, precise positioning, torque control
Textile & DyeingTextile machines, dyeing machines, stenter framesConstant tension, synchronous operation, wide speed range
Plastic & RubberInjection molding, extrusion, blow moldingSignificant energy saving (20~60%), stable pressure control

4.2 Selection Key Points

  1. Power matching: Use VFD055C43A-21 for 5.5kW motors; avoid undersizing.
  2. Load type:

Constant torque (transportadores, mezcladores): use heavy-duty mode (12A).

Variable torque (fans, zapatillas): light-duty mode (10.8A) for better efficiency.

  1. Control requirements:

High-precision positioning: use encoder (PG card) closed-loop vector.

Network control: add communication module (p.ej., PROFINET).

  1. Environment:

High temperature: extra cooling or derating required.

Dusty environment: dust cover + regular fan cleaning.

  1. Modelos de reemplazo & Upgrade Path

5.3 Sugerencias de actualización

  1. Basic upgrade: VFD‑M/GD10 → C2000+ for better precision & functions.
  2. Communication upgrade: Add PROFINET card for Industry 4.0 connectivity.
  3. System upgrade: Combine with Delta PLC (DVP series) & HMI for full automation solution.

Buying Notes

  1. Confirm suffix -21 (standard version), avoid old versions (p.ej., -00).
  2. Verify power & actual: 5.5kW → 12A rated.
  3. Buy from authorized Delta channels for genuine product & service.
  4. Order accessories as needed: communication card, keypad, braking resistor.

VII. Instalación & Maintenance

7.1 Installation Rules

  1. Montaje: Wall/cabinet mount, instalación vertical; ≥150mm clearance top & bottom for ventilation.
  2. Alambrado:

Separate power & control cables to avoid interference.

Shielded cable for signals, single‑end grounding.

Braking resistor matched to power (≤7.5kW internal; external ≈100Ω/500W).

  1. Grounding: Ground resistance ≤4Ω for safety & noise immunity.

Delta VFD055C43A-21 is a high‑performance 5.5kW vector inverter from the C2000+ series, featuring high precision, reliability, and expandability for diverse industrial applications. With built-in PLC, wide voltage tolerance, and complete protection, it is an excellent choice for general industrial drive solutions. Select based on motor power, load type, control requirements, and environment for optimal performance and cost-effectiveness.

Complete Replacement Guide for Delta VFD055C43A-21

  1. Delta Internal Replacements (C2000+ Series, Seamless Compatibility)

1.1 Direct Same‑Series Replacements

Código de fallaCauseSolución
OCsobrecorrienteCheck motor short, sobrecarga, acceleration time
OVSobretensiónCheck mains voltage, deceleration time, braking resistor
UVSubtensiónCheck input phase, Voltaje, cable size
OHOverheatCheck fan, ventilation, temperatura ambiente
PHPhase lossCheck input/output wiring, motor winding

1.2 Near‑Power Replacements

ModeloPowerCorriente nominalCaracterísticas claveSolicitud
VFD055C43A-21 (Original)5.5kilovatios12A / 10.8AC2000+, vector, built-in brake, RS-485General industry
VFD055C43A-21 (Upgraded)5.5kilovatios12ABetter cooling, 10,000-step PLC, more protocolsNew projects
VFD055CH43A-215.5kilovatios12ACH2000, fan/pump specializedaficionados, zapatillas
VFD055CP43B-215.5kilovatios12ACP2000, hoist/crane dedicatedCranes, hoists
  1. Global Brand Replacements (5.5kilovatios / 400V Vector)

2.1 Premium Brands

MarcaModeloSerieControlAdvantage
siemens6SL3210-1KE21-3UF1 (G120C PN)SINAMICS G120CVector/V/FPROFINET, EMC filter
MitsubishiFR-A840-00720-2-60FREQROL A840VectorHigh response, built-in PLC
YaskawaCIMR-AB4A0018FBAA1000VectorLow noise, stable
SchneiderATV320U75N4Altivar 320Vector/V/FCompact, multi-protocol
TEJIDOACS550-01-012A-4ACS550DTCHigh torque accuracy

2.2 Cost‑Effective Brands

MarcaModeloSerieControlAdvantage
InovanceMD280NT5.5GBMD280VectorPROFINET supported
VeichiAC70-T3-055GAC70VectorFull-featured, low cost
INVTCHF100A-5R5G/7R5P-4CHF100AVectorBuilt-in brake un

III. Critical Replacement Rules (Must Follow)

  1. Power & actual: Rated power ≥5.5kW, current ≥12A (heavy duty).
  2. Voltage: 400V class (380~480V) only; do NOT use 200V directly.
  3. Control: Prefer vector control for matching dynamics.
  4. Sobrecarga: At least 150% for 60s.
  5. Comunicación: RS-485 standard; PROFINET/EtherNet/IP optional.

Mechanical Compatibility

Dimensiones: ~90×180×150mm – use same or smaller size.

Cooling: Forced air – keep airflow direction.

Brake unit: Internal for ≤7.5kW; match external if needed.

Keypad: Use Delta standard keypad or compatible.

Best Replacement by Application

General machinery: VFD055C43A-21 upgraded or Siemens G120C PN.

aficionados & zapatillas: VFD055CH43A-21 or Schneider ATV320U75N4.

Cranes/hoists: VFD055CP43B-21 or Mitsubishi FR-A840.

Budget projects: Inovance MD280NT5.5GB or Veichi AC70-T3-055G.

  1. Upgrade Paths

4.1 Delta Internal Upgrade

  1. C2000 → C2000+ (performance & function improvement).
  2. Add PROFINET module (VFD-CM-PN01) for industrial networking.
  3. Pair with Delta PLC + HMI for full automation system.

4.2 Cross‑Brand Upgrade

  1. Comunicación: RS-485 → PROFINET / EtherNet/IP.
  2. Control: Open-loop vector → closed-loop vector with encoder.
  3. Seguridad: Choose models with STO (SIL 2).

The Delta VFD055C43A-21 has a wide range of replacements.

Same‑brand (C2000+ upgraded) offers seamless compatibility.

Cross‑brand (Siemens G120C PN, Mitsubishi FR-A840) provides higher performance.

Always follow core parameter matching to ensure stable, reliable replacement without performance loss or equipment damage.

Anterior:

Deja una respuesta

Dejar un mensaje