chatear: +86-13184948252 Whatsapp: 0086-13811255435 Correo electrónico: kent@bestcontactor.com

Acerca de Contacto |

SCHNEIDER ATS48D88Q Soft Starter - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

inversor solar/medidor de electricidad/eléctrico/

SCHNEIDER ATS48D88Q Soft Starter

Model Code Interpretation Code Segment Description ATS48 Product series: Altistart 48 series soft starter, used for soft start and soft stop control of three-phase squirrel-cage asynchronous motors D Rated current factor: D=1.0, rated current is the base value without multiplier adjustment 88 Corriente nominal: 88A (at 40C ambient temperature) Q Voltage class: 3-phase 230~415V AC ...

  • Detalles del producto

Interpretación del código modelo

Code SegmentDescripción
ATS48Product series: Altistart 48 serie soft starter, used for soft start and soft stop control of three-phase squirrel-cage asynchronous motors
DRated current factor: D=1.0, rated current is the base value without multiplier adjustment
88Corriente nominal: 88A (at 40C ambient temperature)
qVoltage class: 3-phase 230~415V AC (Y=3-phase 208~690V AC)
  1. Parámetros técnicos básicos

Parámetros eléctricos

ArtículoValorDescripción
Rated operating voltage230~415V AC, 50/60Hz3-phase power input
Corriente de funcionamiento nominal88A (40do)Continuous operating current
Suitable motor power45kilovatios (400V normal duty)Matching power for different voltages and applications
37kilovatios (400V heavy duty)
22kilovatios (230V normal duty)
18.5kilovatios (230V heavy duty)
Starting currentNormal duty: 152A (conexión delta) / 88A (line connection)Starting current limits for different connections
Heavy duty: 130A (conexión delta) / 75A (line connection)
Control supply voltage220~415V AC, 50/60HzControl circuit supply
Protection functionssobrecorriente, sobrecarga, pérdida de fase, phase sequence, PTC, underload, sobretensión, subtensión, etc..Comprehensive motor protection
IP ratingIP20Protection against finger contact and solid foreign objects >12milímetros

Physical Parameters

ArtículoValor
Dimensiones (Ancho×Alto×Profundidad)190mm × 290mm × 235mm
PesoAprox.. 8.3kilos
MontajeStandard 35mm DIN rail mounting
  1. Applications
  2. Industrial pumps: Water pumps, oil pumps, bombas de proceso químico, etc., to reduce water hammer during start-up
  3. aficionados: Industrial fans, ventiladores de torre de enfriamiento, boiler induced draft fans, etc., to reduce mechanical shock
  4. Compressors: Compresores de aire, refrigeration compressors, etc., to extend service life
  5. Conveyors: Smooth starting to avoid material spillage
  6. General industry: Three-phase squirrel-cage asynchronous motors requiring soft start/stop control, up to 45kW (400V)
  7. Modelos de reemplazo

4.1 Schneider Same-Series Upgrade/Replacement

Modelo de reemplazoCaracterísticasSolicitud
ATS48D88YWide voltage version (208~690V)For higher voltage applications
ATS480D88YUpgraded version of ATS48 seriesFor higher performance and compatibility
ATS22D88QEconomic alternativeBasic soft start requirements with limited budget

4.2 Cross-Brand Functional Equivalents

MarcaModeloMatch Level
TEJIDOPSE85-600-7085Una corriente nominal, similar functions, fits 45kW motors
siemens3RW4443-6BC4488Una corriente nominal, soft starter, full protection
DeltaMPS500-4545kW soft starter, suitable for industrial automation
  1. Características clave & Notas

Características principales

Soft start modes: Current-limited start, voltage ramp start, current ramp start for various loads

Soft stop function: Linear deceleration stop to prevent pump dry running and water hammer

Built-in intelligent protection: Full motor protection, self-diagnosis and alarm output

Comunicación: Supports Modbus, CANopen, etc., for easy PLC integration

Instalación & Operation Notes

  1. Temperatura ambiente: -10°C ~ +40°C; derate above 40°C
  2. Ensure good ventilation; keep at least 50mm clearance above and below
  3. Control supply and main power must be switched on/off synchronously
  4. Match motor power to soft starter rating to avoid overload
  5. Regularly check cooling fan and terminal connections

Selection Table – Schneider ATS48 Series Q-Type Soft Starters (Including ATS48D88Q)

Solicitud: Soft start/stop for three-phase squirrel-cage motors, 230~415V AC, 50/60Hz, IP20, 35carril DIN mm.

ModeloCorriente nominal (40do)Motor Power (Normal/Heavy Duty)Dimensiones (W*H*D)PesoPower Loss (Full Load)
230V (kilovatios)400V (kilovatios)
ATS48D17Q17A4-37.5/5.5160mm*290mm*235mm4.9kilos59W.
ATS48D22Q22A5.5/411/7.5160mm*290mm*235mm4.9kilos74W.
ATS48D32Q32A7.5/5.511-15160mm*290mm*235mm4.9kilos104W.
ATS48D47Q47A11-922/18.5160mm*290mm*235mm4.9kilos142W.
ATS48D62Q62A11-1530/22190mm*290mm*235mm8.3kilos201W.
ATS48D75Q75A18.5/1537/30190mm*290mm*235mm8.3kilos245W.
ATS48D88Q88A22/18.545/37190mm*290mm*235mm8.3kilos290W.

Key Selection Notes

  1. Power matching rules

Normal duty: Pumps, fans, transportadores (light starting)

Heavy duty: Compressors, crushers, mezcladores; select by heavy-duty power

Ejemplo: ATS48D88Q fits 45kW (400V normal), 37kilovatios (400V heavy)

  1. Tamaño & weight groups

Pequeño (D17Q~D47Q): 160mm wide, 4.9kilos, for small motors

Grande (D62Q~D88Q): 190mm wide, 8.3kilos, better cooling for medium/high power

  1. Reemplazo & upgrade suggestions

Voltage upgrade: q (230~415V) → Y (208~690V), p.ej., ATS48D88Q → ATS48D88Y

Performance upgrade: ATS48 → ATS480 series

Economic option: ATS22 series same current models

  1. Instalación & thermal notes

All IP20; install in enclosed panel

Min. 50mm ventilation above/below

Derate 1% per °C above 40°C

Sync control and main power