Relé de sobretensión/subtensión Schneider serie Easy9 EZ9C1263 - contactor,cortacircuitos,inversor solar,medidor electrico,baterias solares

NoticiasNoticias comerciales

Relé de sobretensión/subtensión Schneider serie Easy9 EZ9C1263

  1. Relé de sobretensión/subtensión Schneider serie Easy9 EZ9C1263

    Relé de sobretensión/subtensión Schneider serie Easy9 EZ9C1263

    Interpretación del modelo

Model ComponentMeaning
EZ9Easy9 Series (Schneider‘s cost-effective series for residential/commercial low-voltage terminal power distribution)
doVoltage control relay (with overvoltage/undervoltage protection function)
12Function type code (representing overvoltage/undervoltage protection + automatic reclosing function)
63Rated current 63A
No suffix2PAG (1P+Ns) pole configuration, suitable for 230VAC single-phase circuits
  1. Parámetros técnicos básicos
Categoría de parámetroValorObservaciones
Tipo de productoOvervoltage/undervoltage relay (with automatic reclosing)Not a miniature circuit breaker, must be used in conjunction with MCB
Número de polo2PAG (1P+Ns, phase line + neutral line)Breaks phase line and neutral line simultaneously to provide complete protection
Corriente nominal (En)63ASuitable for loads below standard 63A
Tensión de funcionamiento nominal (Ue)230V AC 50HzApplicable to single-phase residential/commercial power supply systems
Overvoltage Protection Setting Value275V (tripping time: 3-15s)Graded protection to prevent equipment damage caused by overvoltage of varying degrees
300V (tripping time: 1-5s)
350V (tripping time: 0.25-0.75s)
400V (tripping time: 0.1-0.2s)
Undervoltage Protection Setting Value170V (tripping time: 3-15s)Prevents abnormal operation of equipment due to low voltage
150V (tripping time: 1-5s)
130V (tripping time: 0.25-0.75s)
Reclosing FunctionAutomatic reclosing, maximum 3 reclosing attemptsInterval between each reclosing is about 1 minute to prevent frequent reclosing
Característica de protecciónGraded time-delay protectionAvoids maloperation caused by instantaneous voltage fluctuations
Tensión nominal de aislamiento (interfaz de usuario)440V yCumple con IEC 60947-4-1 estándar
Clase de protecciónIP20Prevents finger contact with live parts, suitable for distribution box installation
Operating Ambient Temperature-5掳C~+60掳CNo derating required during use
Método de instalaciónDIN rail mounting (35mm standard rail)Compatible with other products of Easy9 series for convenient installation
DimensionesModule width: 2 módulos (about 36mm)Compact design, ahorro de espacio en la caja de distribución
Vida útilVida mecánica: 50,000 operacionesCumple con IEC 60947-3 estándar
vida electrica: 20,000 operaciones (at rated current of 63A)

III. Características funcionales principales

  1. Dual Overvoltage/Undervoltage Protection

Overvoltage Protection: Automatically disconnects the circuit when voltage exceeds 275V (±10V) to prevent electrical appliances from being damaged by overvoltage.

Protección contra subtensión: Automatically disconnects the circuit when voltage is lower than 170V (±10V) to avoid burnout of motors and other equipment due to undervoltage overload.

Graded Time Delay: Automatically adjusts tripping time according to the degree of overvoltage/undervoltage to improve protection accuracy.

  1. Automatic Reclosing Function

Automatically recloses after voltage returns to normal without manual intervention.

Maximum reclosing attempt limit (3 veces) to prevent frequent reclosing when faults persist.

Reclosing interval is about 1 minute to ensure circuit stability before reconnection.

  1. Safety Design Highlights

Fault Lockout: Automatically locks in the open position after 3 failed reclosing attempts, requiring manual reset.

Botón de prueba: Manually tests whether the protection function is normal to ensure equipment reliability.

Arc-free Design: No arc ejection during breaking, improving operational safety.

Cooperative Operation with MCB: Must be installed downstream of MCB to utilize MCB for short-circuit and overload protection.

  1. Installation and Application Key Points
  2. Requisitos de instalación

Ubicación de instalación: Must be installed downstream of the miniature circuit breaker (MCB) as a secondary protection device.

Método de cableado: Strictly distinguish phase line (l) and neutral line (norte), with clear markings on wiring terminals.

Installation Direction: Vertically installed on 35mm standard DIN rail, with wiring available at both upper and lower ends.

Condiciones ambientales: Install in a well-ventilated and dry place, avoiding humidity, dust and corrosive gases.

  1. Escenarios de aplicación
Application FieldTypical Usage
Distribución de energía residencialMain distribution box of households, protecting air conditioners, refrigeradores, TVs and other household appliances from voltage fluctuation damage
Edificios ComercialesOffices, tiendas, hotel guest rooms, etc., protecting computers, printers and other office equipment
Small-scale IndustryControl circuits of single-phase equipment, protecting PLC, frequency converters and other precision electronic devices
Photovoltaic SystemsFront end of single-phase grid-connected inverters, protecting inverters from grid voltage fluctuations
  1. Recommended Supporting Equipment

MCB Matching: It is recommended to use Schneider Easy9 series EZ9F53263 (2P 63A C-curve, capacidad de corte 6kA).

Distribution Box: Easy9 series compact distribution box with IP43 protection class, suitable for rail mounting.

Wiring Terminals: Use copper lugs for connection to ensure good contact and reduce heating risk.

 

  1. Selección y soluciones alternativas
  2. Selection Key Points

Confirm circuit type: Only applicable to 230VAC single-phase circuits; other models should be selected for three-phase circuits.

Match load current: Rated current ≥ maximum load current; 63A is recommended for residential main protection.

Use with MCB: Must be used in conjunction with MCB and cannot be used alone as a circuit protection device.

  1. Alternative Model Reference
Demand ScenarioModelo recomendadoDifference Description
No Reclosing RequiredEZ9C1163Only overvoltage/undervoltage protection, without automatic reclosing function
40A Rated CurrentEZ9C1240Suitable for branch circuit protection with small load current
Integrated Leakage ProtectionEA9ZGQ263Integrated design of overvoltage/undervoltage + leakage protection + automatic reclosing
Three-phase CircuitsSelect Acti9 series voltage relayApplicable to 400VAC three-phase circuits
  1. Fault Diagnosis and Maintenance
Fenómeno de fallaPosibles causasMétodos de solución de problemas
Tropiezos frecuentesLarge grid voltage fluctuations; low setting value; abnormal loadCheck grid quality; adjust setting value; troubleshoot load faults
No ActionError de cableado; power supply failure; relay damageVerify wiring diagram; check power supply; replace the relay
Reclosing FailurePersistent faults; exceeded reclosing attempt limitTroubleshoot circuit faults; manually reset before reconnection
Calentamiento anormalCableado suelto; load overload; excessively high ambient temperatureTighten wiring; check load; improve ventilation conditions

Resumen

Schneider EZ9C1263 is an overvoltage/undervoltage relay specially designed for 230VAC single-phase circuits. Its core advantage lies in the automatic reclosing function, which can automatically restore power supply after voltage returns to normal, improving the convenience of electricity use. As a member of the Easy9 series, its compact design, DIN rail mounting and high reliability make it an ideal choice for protecting precision electronic equipment in residential and small-scale commercial buildings. It should be noted that this product is not a miniature circuit breaker and must be used in conjunction with MCB to achieve complete short-circuit, overload and voltage protection functions.