Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

 ACS 310-01E-02A4-2 ABB General-Purpose Inverter - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

NouvellesActualités commerciales

ACS 310-01E-02A4-2 ABB General-Purpose Inverter

Product Overview & Model Explanation

ACS 310-01E-02A4-2 is a general-purpose inverter from the ABB ACS310 series with single-phase 230 V input and three-phase output. It is mainly designed for variable-torque applications such as fans and pumps, with IP20 protection and C3 EMC filter compatibility.

Model Code Breakdown (ABB ACS310 Naming Convention)

CodeSignificationDescription
ACS 310Basic seriesACS310 = general-purpose inverter, optimized for fan & pump variable-torque loads
01ECadre & enclosure01 = Frame R1; E = IP20, no built-in filter (external filter required)
02A4Rated output & tension02A = rated output current 2.4 UN (0.37 kW); 4 = voltage class (200–240 V)
2Input phase2 = single-phase input (200–240 V), three-phase 200–240 V output
  1. Core Technical Specifications

2.1 Electrical Data

ArticleSpécification
Input powerSingle-phase 200–240 V AC, 50/60 Hz, ±10% tolerance
OutputThree-phase 0–240 V AC, 0–500 Hz, 0.37 kW / 2.4 UN, 150% overload for 60 s
Control modeV/f control (flux vector optional), built-in PID and PFC (pump/fan control)
Digital I/O2 entrées numériques, 1 relay output (250 V AC/2 A, 30 V DC/2 A)
Analog I/O1 analog input (0–10 V or 4–20 mA), 1 analog output (0–20 mA)
CommunicationBuilt-in Modbus EIA-485, Modbus RTU supported
EMCCategory C3 (industrial environment), external filter required

2.2 Caractéristiques mécaniques

ArticleSpécification
CadreR1 (132 × 175 × 155 mm, W × H × D)
MontageWall or cabinet mounting, vertical installation; ≥100 mm clearance top & bottom
ProtectionIP20
TempératureOperating: -10 °C to +40 °C (derate above 40 °C); Storage: -40 °C to +70 °C
PoidsEnviron. 1.5 kilos
CoolingNatural convection (no fan)
  1. Key Functions & Applications

3.1 Fan & Pump Special Functions

Built-in multi-pump control (up to 4 pompes), alternation and automatic backup

Pipe cleaning and priming functions for system commissioning and maintenance

Sleep / wake-up function for significant energy saving

Anti-blockage and dry-run protection for pumps

Motor noise smoothing to reduce noise

3.2 Applications typiques

ApplicationSuitable EquipmentKey Benefits
Systèmes CVCCentrifugal fans, pompes, cooling tower fans30–50% energy saving, stable, low noise
Water treatmentBooster pumps, submersible pumps, sewage pumpsDry-run protection, multi-pump control
Industrial circuitsCooling pumps, lubrication pumpsLonger service life, lower maintenance
Small machineryConveyors, mélangeurs, small compressorsEasy to use, rentable
  1. Series Models & Alternatives

4.1 ACS310 Series (Frame R1, 200–240 V single-phase)

ModèleRated PowerCourant nominalMain DifferenceApplication
ACS310-01E-02A4-20.37 kW2.4 UNBasic modelSmall fans, micro pumps
ACS310-01E-04A7-20.75 kW4.7 UNHigher powerSmall/medium fans & pompes
ACS310-01E-07A5-21.5 kW7.5 UNHigher powerMedium fans & pompes
ACS310-01E-09A8-22.2 kW9.8 UNHigher powerLarge fans & pompes

4.2 Recommended Alternatives

AlternativeMain DifferenceApplication
ACS310-03E-02A4-4Three-phase 380–480 V input, 0.37 kWIndustrial three-phase systems
ACS355-01E-02A4-2Full-featured, built-in EMC filterHigher EMC & functional requirements
ACS580-01-03A3-4Vector control, 180% surchargeHigh dynamic & precision control
  1. Accessories & Options
AccessoireType CodeDescription
Control panelCDP312RBasic control and parameter setting
Advanced panelCDP312R-ETHWith Ethernet, remote monitoring
EMC filter3AFE68300909C3 EMC filter for industrial environment
Brake unitACS-BU-01For frequent start/stop and braking
I/O extension3AXD500000387624 DI + 2 DO expansion
Comm module3AXD50000038763Profibus-DP interface
  1. Installation & Troubleshooting

6.1 Installation Notes

  1. Electrical installation

Input must be protected by a circuit breaker and fuse matching 2.4 UN

Output cable: shielded, maximum. 50 m to prevent motor overvoltage

Separate control wiring from power wiring by ≥100 mm

  1. Mechanical installation

Mount vertically with sufficient ventilation

Derate 1% per °C above 40 °C

Avoid high vibration, dust, moisture, corrosive gas

6.2 Fault Codes

CodeDescriptionCause possibleSolution
F001SurintensitéShort circuit, motor overload, wrong settingsCheck wiring, reduce load, reset parameters
F002SurtensionHigh supply voltage, fast decelerationCheck supply, adjust deceleration time
F003Sous-tensionLow voltage, phase lossCheck input power
F004OvertemperaturePoor ventilation, blocked heatsinkImprove cooling, clean heatsink
F005Motor overloadExcess load, stallReduce load, check motor
F006Earth faultOutput grounded, motor insulation faultCheck cable and motor
  1. Selection & Application Advice
  2. By load type

Fan/pump variable-torque loads: ACS310 series recommended

Constant-torque loads (convoyeurs, mélangeurs): ACS355 or ACS580

  1. By power

≤ 0.37 kW: ACS310-01E-02A4-2

0.37–2.2 kW: ACS310-01E series

> 2.2 kW: ACS310-03E three-phase series

  1. Energy-saving analysis

Fans and pumps can save 30–50% energy with VFD control

Use ABB DriveSize for accurate selection and energy calculation

As an entry-level model of the ABB ACS310 series, the ACS 310-01E-02A4-2 features compact design, easy operation, and fan/pump‑optimized functions, making it an ideal choice for small industrial and commercial applications. For advanced control or higher performance, upgrade to ACS355 or ACS580 series.

Précédent:

Laisser une réponse

Laisser un message