ABB ESB20-20N-06 Technical Analysis Report This is a 2-pole, 20UN, 2NON, 230V AC/DC universal coil modular installation contactor, suitable for single-phase load control in residential and industrial environments. It features silent operation, low power consumption, and integrated overvoltage protection, with a width of only 18mm and standard 35mm DIN rail mounting. Order code: 1SBE121111R0620. Modèle ...

  • Détails du produit

ABB ESB20-20N-06 Technical Analysis Report

This is a 2-pole, 20UN, 2NON, 230V AC/DC universal coil modular installation contacteur, suitable for single-phase load control in residential and industrial environments. It features silent operation, low power consumption, and integrated overvoltage protection, with a width of only 18mm and standard 35mm DIN rail mounting. Order code: 1SBE121111R0620.

  1. Model Breakdown
Segment de modèleDescription
ESBProduct family: ABB ESB series building / installation contactors
20Courant nominal: 20UN (AC-1 duty)
20Main contact configuration: 2 NON, 0 Caroline du Nord
NFamily identifier: Standard ESB..N installation contactor (vs. EN..N with manual switch)
6Coil voltage code: 230V AC/DC universal
  1. Spécifications de base

Electrical Data

ArticleValeurRemarques
Rated operational current (AC-1)20UNCharge résistive
Rated operational power (AC-7a, 230V)4.6kWSingle-phase motor load
Rated operational current (AC-3, 230V)9UNSingle-phase motor load
Tension d'isolement nominale (Interface utilisateur)400VIEC compliant
Rated impulse withstand voltage (Ump)6kVIEC compliant
Coil voltage230V CA/CCUniversal, no polarity required
Coil powerInrush: ~12VA/10WLow-power, energy-saving design
Sealed: ~2VA/2W
Control circuit frequency50/60HzUniversal range

Mécanique & Environmental Data

ArticleValeurRemarques
Nombre de pôles22 main circuits
Contact configuration2NON + 0Caroline du NordNo auxiliary contacts
Mechanical durability1,000,000 opérationsHigh endurance
Electrical durability (AC-7a/7b)150,000 opérationsCEI 60947-4-1 compliant
Width18mmModular, space-saving
Montage35mm rail DINStandard mounting
Température de fonctionnement-25°C ~ +55°CWide temperature range
Storage temperature-40°C ~ +85°CHigh-reliability design
Protection degreeIP20Finger-safe, suitable for distribution boards
  1. Description de la fonction
  2. Universal coil technology: AC/DC universal coil, no AC/DC distinction, flexible installation, completely silent and vibration-free operation.
  3. Integrated overvoltage protection: Built-in overvoltage suppression in control circuit, improves system reliability and service life.
  4. Conception modulaire: Seulement 18 mm de large, fully compatible with other modular DIN rail components, saves cabinet space.
  5. Compatibilité des accessoires: Supports standard accessories (contacts auxiliaires, mechanical interlocks, etc.), tool-free plug-and-play installation.
  6. Safety design: Complies with EN/IEC/UL standards, provides reliable electrical isolation for personnel and equipment safety.
  7. Wide application: Suitable for controlling electric heaters, hot water systems, pump/fan motors, lighting and other single-phase loads.
  8. Recommandations de sélection

Suitable Applications

Éclairage, chauffage, ventilation control in residential and commercial buildings

Single-phase motor control (pompes, les fans) for small industrial equipment

Noise-sensitive environments (hospitals, bureaux, homes)

Space-limited distribution boards / armoires de commande

Selection Criteria

  1. Load type matching:

Charge résistive (AC-1): Use 20A rated current directly

Motor load (AC-7a/7b): Recommended ≤9A (4.6kW) at 230V single-phase

Inductive load: Derating or surge suppressor recommended

  1. Coil voltage selection:

Match control system supply (230V CA/CC)

Other voltages available: ESB20-20N-01 (24V), ESB20-20N-04 (110V)

  1. Contact configuration:

This model: 2NON, suitable for two independent circuits

For NC contacts: ESB20-02N series (2Caroline du Nord)

For auxiliary contacts: Add auxiliary contact modules

  1. Environmental conditions:

Derate above +40°C ambient temperature

Extra protection required in humid or corrosive environments

  1. Installation Notes

Pre-Installation

Verify model matches order, inspect for physical damage

Confirm coil voltage matches control supply

Prepare standard 35mm DIN rail and suitable terminals

Installation Procedure

Clip contactor firmly onto 35mm DIN rail

Wire main and control circuits per diagram; coil is non-polarized

Terminal torque: 2.5N·m (conductor: 0.5–2.5mm²)

Accessories clip directly onto top/side without tools

Sécurité

Isolate and verify voltage-free before installation

Separate main and control wiring to avoid interference

Ensure adequate ventilation to prevent overheating

Maintain ≥5mm clearance around contactor for heat dissipation

Mise en service & Entretien

Check wiring before first energization

Test contactor operation for correct switching and no abnormal noise

Inspect contacts and terminal tightness regularly (at least annually)

  1. Modèles alternatifs

Same-Series Alternatives

ModèleDifferenceApplication
ESB20-20N-0124V AC/DC coilLow-voltage control systems
ESB20-20N-04110V AC/DC coil110V control systems
ESB20-02N-062NC configurationApplications requiring normally closed contacts
EN20-20N-06With manual operatorEmergency manual control

Upgraded Alternatives

ModèleMise à niveauApplication
ESB25-20N-0625Un courant nominalHigher load requirements
ESB40-40N-064-pôle, 40UNThree-phase or higher current
ABB AF seriesIndustrial contactorsHeavy-duty industrial environments

ABB ESB20-20N-06 is a compact, high-performance installation contactor. With silent operation, universal coil, low power consumption and modular design, it is an ideal solution for single-phase load control in residential and industrial applications. Proper selection, installation and maintenance ensure long-term reliable performance and safe, efficient control for electrical systems.

ABB Contactor Standard Selection Procedure

(Industrial & Building, for sales / quotation / design)

Using ESB (building) and AF/A (industriel) as examples – 8-step precise selection ready for proposals and quotations.

  1. Define Application & Product Family

Building / Résidentiel / Distribution board: Éclairage, chauffage, pompes, les fans, small motors → ESB/EN series (silent, DIN rail, narrow width)

Industrial / Equipment / Control cabinet: Ventilateurs, pompes, compresseurs, motor main circuits → AF/A series (wide voltage, long life, heavy-duty)

  1. Determine Load Category (Critical for Derating)

Per IEC 60947 utilization categories:

AC-1: Charges résistives (radiateurs, éclairage) → use rated current directly

AC-3: Squirrel-cage motor DOL (most common industrial) → motor current ≤ contactor rated current

AC-7a/7b: Building small motors, les fans, pumps → use building contactor rated values

  1. Calculate Operating Current & Capacité nominale
  2. Determine current from power / tension
  3. Allow 1.1–1.25x safety margin (inrush, continuous duty)
  4. Select corresponding rated current (C'est à dire) from ABB catalog

Exemple: 230V single-phase 2kW heater ≈ 8.7A → ESB20-20N is sufficient

  1. Select Number of Poles

1P.: Monophasé, single circuit

2P.: Monophasé, double-pole (L+N switching, building standard)

3P.: Three-phase motors / industriel (most common)

4P.: Triphasé + N or double-break

  1. Select Coil Voltage & Taper
  2. Control voltage: 24V, 110V, 230V, 400V, etc..
  3. Coil type:

Building: AC/DC universal coil (ESB series, non-polar, silent)

Industrial: Wide-range coil (AF series, stable at 85–110% Un)

  1. Define Auxiliary Contact Requirements

Built-in: From model (20=2NO, 02=2NC)

Expandable: EH series auxiliary contacts (1NON+1NC, 2NON, etc.)

Used for: Status feedback, interlocking, sequential control

  1. Environnemental & Exigences particulières

Altitude >1000m, temperature >40°C → derate or upsize

Silent requirement (residential/office): Must use ESB silent type

Protection: IP20 normally sufficient for panel mounting

Mechanical interlock / reversing: Use dedicated interlock accessories

  1. Final Verification: Modèle + Certifications
  2. Confirm full model: family–current–contacts–coil

Exemple: ESB20-20N-06

  1. Verify certifications: CCC, CEI, RoHS
  2. Confirm mounting: 35mm rail DIN / screw mounting

Simplified Selection Mnemonic

  1. Choose family by application
  2. Choose duty by load type
  3. Calculate current with margin
  4. Confirm poles and coil voltage
  5. Add aux contacts for control
  6. Check environment and derate
  7. Verify model for final list