Wechat: +86-13184948252 WhatsApp: 0086-13811255435 E-mail: kent@bestcontactor.com

À propos Contact |

Contacteur domestique Chint NCH8-20/20 - Contacteur,disjoncteur,onduleur solaire,compteur électrique,batteries solaires

contacteur/

Contacteur domestique Chint NCH8-20/20

The Chint Household Contactor NCH8-20/20 is a modular contactor specifically designed for residential and smallcommercial scenarios. It is mainly used to control lowinductance loads or motor equipment. je. Model and Parameter Interpretation 1. Model Meaning NCH8: It is the series name, representing Chint’s household contactor product line. 20: The rated current of the ...

  • Détails du produit

The Chint Household Contactor NCH8-20/20 is a modular contactor specifically designed for residential and smallcommercial scenarios. It is mainly used to control lowinductance loads or motor equipment.

je. Model and Parameter Interpretation

1. Signification du modèle

NCH8: It is the series name, representing Chint’s household contactor product line.

20: The rated current of the main contact is 20A, which is suitable for resistive loads (such as electric heating equipment and lamps). In this case, the maximum power can reach 220V × 20A = 4.4kW.

/20: The contact configuration is 2 sets of Normally Open (NON) + 0 sets of Normally Closed (Caroline du Nord), which means it only supports the onoff control of a single circuit.

Tension de bobine: It supports 220/230V AC by default, and a 24V AC version is also available (par ex., NCH8-20/20 24V).

2. Paramètres clés

Numéro de pôle: 2P. (singlephase), suitable for 220V singlephase circuits.

Application Category: CA – 1 (charges résistives), CA – 7un (household motor loads). When controlling motors, the capacity needs to be derated to approximately 9A.

Durée de vie mécanique: 1,000,000 fois; Durée de vie électrique: 100,000 fois, doté d'une forte durabilité.

Attestation: It has passed the CCC certification and complies with the GB/T 17885 et CEI 61095 normes.

Ii. Scénarios d'application

1. Home Automation

It controls the start and stop of highpower electrical appliances (comme les climatiseurs, electric water heaters, and heat pumps) to realize timing or remote control.

It is matched with smart switches or PLCs to build a smart home system (such as light linkage and curtain control).

2. Petit – Commercial Equipment

It controls the circuit onoff of hotel cardoperated power supply systems, petites pompes à eau, and commercial kitchen appliances (such as coffee machines and ovens).

It replaces traditional relays, simplifies the layout of distribution boxes, and improves space utilization.

III. Caractéristiques du produit

1. Mute Design

It adopts a directacting structure, and the pullin noise is lower than 20dB, making it suitable for places sensitive to environmental noise (such as bedrooms and hospitals).

2. Convenient Installation

It supports the installation of TH35 – 7.5mm standard guide rails, which can be quickly clamped into the distribution box, saving installation time.

The labels on the terminal blocks at the back are clear (L1/L2 are connected to the power supply, T1/T2 are connected to the load, and A1/A2 are connected to the control signal), and it is compatible with wires with a crosssectional area of less than 2.5mm².

3. Safety Protection

The shell is made of flameretardant materials, with an IP20 protection rating to prevent accidental electric shock.

Each product is attached with an independent anticounterfeiting code, and the authenticity can be verified by scanning the code.

IV. Suggestions de sélection et d’utilisation

1. Correspondance de charge

Resistive Loads: Select directly according to the rated current of 20A, Par exemple, when controlling electric heaters with a total power of ≤ 4.4kW.

Charges inductives (comme les moteurs): The capacity needs to be derated to approximately 9A, Par exemple, when controlling singlephase water pumps with a power of less than 1.5kW.

Contrôle de l'éclairage: You can refer to the official selection table. Par exemple, the NCH8 – 20/20 can support a maximum of 20 60W incandescent lamps or 17 35W fluorescent lamps (with parallel compensation).

2. Alternative Model Reference

If more contacts are needed, you can choose NCH8 – 20/31 (3NON + 1Caroline du Nord) or NCH8 – 20/22 (2NON + 2Caroline du Nord).

For manual operation scenarios, you can consider the NCH8M series (such as NCH8 – 20M/20), which supports temporary onoff control via a handle.

3. Price and Purchase

The reference market price is about 49.73 RMB per unit (for the 220V version), and discounts are available for bulk purchases.

It is recommended to purchase via Chint’s WhatsApp: 0086 – 13811255435 to ensure product quality and aftersales service.

V. Installation and Wiring Steps

1. Preparation of Tools

– Tournevis, pince à dénuder, multimètre, and insulating tape.

2. Guide Rail Installation

Fix the 35mm guide rail in the distribution box to ensure stability.

Align with the card slot at the back of the contactor and press down until the buckle is locked.

3. Circuit Connection

Main Circuit: Connect L1/L2 to the live wire and neutral wire of the 220V power supply, and connect T1/T2 to the load (such as the outdoor unit of an air conditioner).

Circuit de contrôle: Connect A1/A2 to the control signal (such as the output of a switch or timer). For the 24V version, an additional transformer needs to be configured.

4. Testing and Debugging

Before poweron, check whether the wiring is firm, and use a multimeter to measure the coil resistance (the 220V version has a resistance of approximately 1.5kΩ).

Shortcircuit A1/A2, observe whether the contactor pulls in normally and whether the contact actions are synchronized.

VI. Précautions

1. Exigences de dissipation thermique

When multiple contactors are installed densely, spacing pieces (about 18mm) need to be reserved to avoid overheating and capacity reduction.

When the ambient temperature exceeds 40℃, it is recommended to use the contactor with derated capacity (Par exemple, the 20A model can only carry 16A at 50℃).

2. ShortCircuit Protection

A small circuit breaker (such as DZ47 – 63) must be connected in series, and the breaking capacity should be ≥ 6kA to prevent equipment damage due to faults.

3. Regular Maintenance

Check the contact wear condition every year. If the contact thickness is reduced by 1/3, it should be replaced in a timely manner.

Clean the dust on the shell to ensure that the heat dissipation holes are unobstructed, so as to avoid the decline of insulation performance caused by dust accumulation.