Wechat: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Di Contatto |

Dimensioni di montaggio di Chint NM1-800H/3300-800A - Contattore,interruttore automatico,inverter solare,contatore elettrico,batterie solari

NotiziaNotizie commerciali

Dimensioni di montaggio di Chint NM1-800H/3300-800A

Data is derived from the official manual of Chint NM1 series, all units are in mm, and the accuracy is subject to the physical product:

  1. Core Mounting and Overall Dimensions (3-pole, front wiring, manual operation)
ParametroValoreDescription
Dimensioni complessive (W×D×H)243×270×448Width W=243, Depth D=270, Height H=448
Mounting Hole Spacing200Center distance between two holes on the mounting plate
Mounting Hole DiameterΦ10Suitable for M10 bolts
Mounting Plate Thickness≥5It is recommended to use a mounting plate with a thickness of ≥5mm
Arc Flash Distance≤100Sufficient arc flash space shall be reserved
Handle Height172Height from the top of the handle to the mounting plate
  1. Dimensional Differences for Different Wiring Methods
Wiring MethodCore Dimensional ChangeRemarks
Front WiringWidth 243, Depth 270, Height 448Default standard dimension
Rear WiringDepth increased to about 280Matching rear wiring board is required, mounting hole positions remain unchanged
Plug-in TypeDepth increased to about 290Suitable for plug-in base, mounting hole positions remain unchanged

III. Key Points for Mounting and Fastening

  1. Mounting method: Vertical or horizontal mounting is supported; the mounting plate shall be flat and firm to ensure good heat dissipation.
  2. Tightening torque: M12 bolts for main wiring terminals, the recommended tightening torque is 28N·m to ensure reliable wiring.
  3. Bus bar adaptation: For a rated current of 800A, it is recommended to use bus bars of ≥240mm² to meet the current-carrying capacity and heat dissipation requirements.
  4. Space reservation: An arc flash distance of ≥100mm shall be reserved around to avoid potential safety hazards caused by short-circuit electric arcs.

Cross-Brand Model Comparison Table for Chint NM1-800H/3300-800A

The following comparison is based on the core parameter matching of 3-pole, 800A rated current, H-grade breaking capacity (50kA@400V), thermomagnetic tripping (combined tripping), no accessories. Data is derived from the official samples of various brands. Please check the detailed technical parameters and mounting dimensions before replacement.

  1. Corresponding Models of Mainstream International Brands
s
MarcaCorresponding ModelKey Parameter MatchingReplacement Notes
SchneiderNSX800H TMD 800 3P3D• 3-pole, 800UN1. Mounting dimension difference: NSX800 (Width 243mm, Depth 270mm, Height 448mm), consistent with Chint
NS800H 3P 800A• H-grade breaking capacity (50kA@400V)2. Tripping curve shall match the protection requirements of the original system
• TMD thermomagnetic tripping3. Accessory compatibility: Interfaces of auxiliary/shunt trip devices are different
ABBTmax T6N 800/3P 800A• 3-pole, 800UN1. Slightly larger mounting depth (about 280mm)
T6H 800/3P 800A• N-grade (50IL)/H-grade (70IL) potere di interruzione2. Confirm that the tripper type is thermomagnetic (TMD)
• Thermomagnetic tripping unit3. Bus bar wiring methods may vary
Siemens3VT800N-3NF00-800A• 3-pole, 800UN1. Dimensioni complessive: Width 240mm, Depth 265mm, Height 440mm (slightly different)
3VT800H-3NF00-800A• N-grade (50IL)/H-grade (70IL) potere di interruzione2. Operating mechanism is different from Chint, need to confirm the mounting space
• Thermomagnetic tripping3. Protection characteristics shall be consistent with the original system
EatonIZM91H3-U800• 3-pole, 800UN1. Breaking capacity is optional; priority is given to N-grade (50IL) to match Chint H-grade
IZM91N3-U800• H-grade (70IL)/N-grade (50IL) potere di interruzione2. Terminals specifications are different, need to adapt to bus bars
• Thermomagnetic tripping
  1. Corresponding Models of Well-Known Domestic Brands
MarcaCorresponding ModelKey Parameter MatchingReplacement Notes
Changshu SwitchCM1-800H/3300-800A• 3-pole, 800UN1. Fully compatible mounting dimensions (same as Chint NM1 series)
CM3-800H/3300-800A• H-grade breaking capacity (50kA@400V)2. Slight difference in tripper sensitivity, on-site commissioning is required
• Thermomagnetic combined tripping3. High accessory universality, direct replacement is available
DELIXICDM3-800H/3300-800A• 3-pole, 800UN1. Consistent overall dimensions: Width 243mm, Depth 270mm, Height 448mm
CDM3S-800H/3300-800A• H-grade breaking capacity (50kA@400V)2. Obvious price advantage and high cost performance
• Thermomagnetic tripping3. Slight difference in breaking capacity curve from Chint
Shanghai People’s SWRMM1-800H/3300-800A• 3-pole, 800UN1. Compatible mounting dimensions
• H-grade breaking capacity (50kA@400V)2. Tripper type is exactly the same as Chint
• Thermomagnetic combined tripping3. Comprehensive after-sales service network coverage
Chint Upgraded ReplacementNXM-800H/3300-800A• 3-pole, 800UN1. Upgraded model of NM1 series with improved performance
• H-grade breaking capacity (50kA@400V)2. Fully consistent mounting dimensions for direct replacement
• Thermomagnetic tripping3. Optimized protection characteristics, more suitable for modern power distribution systems

III. Core Technical Points for Replacement

  1. Mandatory Matching Items for Key Parameters
ParametroMatching RequirementRisk of Mismatch
Numero di poliMust be 3PSingle-phase/three-phase unbalance and protection failure
Corrente nominaleMust be 800AOverload protection failure and line overheating
Capacità di interruzione≥50kA@400VFailure to break reliably in case of short-circuit fault, leading to arc accidents
Tripper TypeMust be thermomagnetic combined trippingNo overload protection (magnetic tripping only) or mismatched protection characteristics
Mounting DimensionsW×D×H≈243×270×448mmInability to install or impact on adjacent equipment
  1. Replacement Operation Steps
  2. Cut off the power and test for no voltage to ensure safety.
  3. Remove the original circuit breaker and record the wiring method and phase sequence.
  4. Install the new circuit breaker and fasten according to the manufacturer’s torque requirements (28N·m for M12 bolts of main terminals).
  5. Check the tripper settings (long-delay current 800A, instantaneous multiple 10-12 volte).
  6. Power on for testing and check the closing/opening actions and protection functions.
  7. Accessory Replacement Suggestions
Original AccessoryReplacement SolutionNote
Auxiliary ContactAuxiliary contact of the same specification from the corresponding brandTerminal definitions may be different
Shunt Trip DeviceShunt trip device matching the new circuit breakerControl voltage must be consistent (AC220V/380V)
Undervoltage Trip DeviceUndervoltage trip device of the same brandDifferences in mounting position and interface
  1. Supplementary Selection Instructions
  2. Breaking capacity upgrade: If the system short-circuit current is greater than 50kA, models with H-grade (70IL) breaking capacity can be selected (per esempio., Schneider NSX800H, ABB T6H).
  3. Intelligent upgrade: Models with communication functions can be considered (per esempio., Schneider NSX800H with Micrologic 5.0) to realize remote monitoring.
  4. Cost optimization: Domestic brands (Changshu CM3, DELIXI CDM3) are about 60-70% of the price of international brands with equivalent performance.

Prec:

Prossimo:

Lascia una risposta

Lasciate un messaggio