Schneider Electric MCB A9P52606

Schneider Electric A9P52606 is a interruttore automatico miniaturizzato (MCB) of the Acti9 iC40 series, featuring 1P+N pole configuration, 6A rated current, and C-type tripping curve. It is designed for overload and short-circuit protection of conventional distribution circuits such as lighting and socket systems, with a rated breaking capacity of 6kA (IEC 60947‑2)/4.5IL (IN 60898). It adopts DIN rail mounting and has an IP20 protection rating.

  1. Model Interpretation
ItemDetails
ModelloA9P52606
SeriesActi9 iC40
TipoMiniature Circuit Breaker (MCB)
Configurazione del palo1P+N (1 protective pole, N pole for switching only)
Corrente nominale6UN
Tripping CurveTipo C
Capacità di interruzione6IL (IEC 60947‑2), 4.5IL (EN 60898‑1)
Metodo di montaggioDIN Rail
Protection RatingIP20
  1. Parametri tecnici fondamentali
ParametroValoreStandard
Rated Operational Voltage (Ue)230V CA 50/60 HzEN/IEC 60947‑2
Corrente nominale (In)6UNEN/IEC 60947‑2
Caratteristica di interventoTipo C (instantaneous tripping at 5In‑10In)EN/IEC 60898‑1
Ultimate Breaking Capacity (Icu)6IL (230V e)EN/IEC 60947‑2
Service Breaking Capacity (Icn)4.5IL (230V e)EN/IEC 60898‑1
Rated Impulse Withstand Voltage (Uimp)4kVEN/IEC 60947‑2
Overvoltage CategoryEN/IEC 60947‑2
Grado di inquinamento3EN/IEC 60947‑2
Operating Temperature-25℃~70℃EN/IEC 60947‑2
Vita elettrica20,000 operazioniEN/IEC 60947‑2
Vita meccanica20,000 operazioniEN/IEC 60947‑2
Dimensioni (W×D×H)1 module (18mm) × 44mm × 91mmSchneider Electric Technical Manual
Neutral Pole PositionLeft SideSchneider Electric Technical Manual
Tripping Unit TypeThermal-magneticSchneider Electric Technical Manual
  1. Caratteristiche funzionali
  2. 1P+N Design: Live wire protection plus synchronous neutral wire switching, suitable for single-phase distribution systems, with clear wiring and convenient maintenance.
  3. Type C Tripping Curve: Suitable for conventional loads such as lighting and sockets, balancing overload time-delay and short-circuit instantaneous tripping, with strong resistance to inrush current.
  4. High Breaking Capacity: 6IL (IEC 60947‑2)/4.5IL (EN 60898‑1), capable of handling severe short-circuit faults and ensuring distribution safety.
  5. Standard Mounting: DIN rail mounting with 1-module width, saving switchgear space, and compatible with Acti9 series accessories (per esempio., contatti ausiliari, alarm contacts).
  6. Adattabilità ambientale: IP20 protection rating, resistant to temperatures ranging from -25℃ to 70℃, meeting the requirements of industrial and civil distribution environments.
  7. Application Scope

Overload and short-circuit protection for single-phase distribution circuits of lighting, sockets, small motors, ecc., in commercial buildings and industrial plants.

Places with high requirements for power supply reliability, such as office buildings, Hotel, and hospitals.

Compatible with Acti9 series distribution boxes, used in scenarios such as terminal power distribution and branch circuit protection.

  1. Raccomandazioni per la selezione
  2. Carica corrispondenza: Type C curve is suitable for non-inductive loads (per esempio., illuminazione, sockets); avoid selecting Type D (per carichi di potenza) or Type B (for electronic equipment) curves.
  3. Circuit Matching: With a rated current of 6A, it is suitable for 1.5mm² copper core cables (long-term current-carrying capacity ≥ 10A), and the circuit length should be ≤ 100m.
  4. Capacità di interruzione: The 6kA breaking capacity is suitable for terminal distribution; the front-end should be equipped with molded case circuit breakers with higher breaking capacity (per esempio., 15kA and above).
  5. Accessory Selection: According to monitoring requirements, select accessories such as auxiliary contacts (per esempio., A9A26924) and alarm contacts (per esempio., A9A26934).
  6. Risoluzione dei problemi
Fenomeno di guastoPossibili causeTroubleshooting Methods
Frequent TrippingOverload, line grounding/short-circuit, mismatched tripping curveCheck load current and insulation resistance; replace MCB with a matching tripping curve
Failure to CloseUnreset tripping mechanism, line short-circuit, contact ablationManually reset the trip lever, locate the short-circuit point, replace damaged contacts
Excessive Temperature RiseLoose wiring, ossidazione da contatto, high ambient temperatureTighten wiring terminals, polish contacts, improve ventilation and heat dissipation
Insufficient Breaking CapacityLack of front-end protection, excessive short-circuit current in the lineUpgrade front-end protection, select MCB with higher breaking capacity
  1. Soluzioni alternative

Intra-series Alternatives: A9P52610 (1P+N, 10UN, Tipo C), A9P52616 (1P+N, 16UN, Tipo C), ecc., maintaining mounting and accessory compatibility.

Cross-series Alternatives: Schneider Electric IDPN series (per esempio., A9D18606, 1P+N, 6UN, Tipo C) or ABB S200 series (per esempio., S201M‑C6, 1P+N, 6UN, Tipo C). It is necessary to verify the matching of mounting dimensions and breaking capacity.

Complete Guide to Other Models of Schneider Electric Acti9 iC40 Series

Schneider Electric Acti9 iC40 series is a miniature circuit breaker (MCB) specially designed for single-phase/three-phase distribution systems. With 1P+N as the core product, it also provides multiple pole configurations including 2P, 3P, 4P, and 3P+N. The tripping curves cover Type B/C/D, and the breaking capacity is divided into standard type (4.5kA Icn/6kA Icu) and Type N (6kA Icn/10kA Icu), with rated current covering the full range of 1A~63A. The following is a structured and complete list of models:

  1. Model Naming Rules (A9PXXXXXX)
PositionCodeMeaning
1-2A9Acti9 Series Identifier
3PExclusive Code for iC40 Series
42-4Capacità di interruzione: 2 = Standard Type (4.5kA/6kA), 4 = Type N (6kA/10kA)
56/2/3/4/7Configurazione del palo: 6 = 1P+N, 2 = 2P, 3 = 3P, 4 = 4P, 7 = 3P+N
6-701~63Corrente nominale: 01 = 1A, 02 = 2A, 04 = 4A, 06 = 6A, 10 = 10A, 16 = 16A, 20 = 20A, 25 = 25A, 32 = 32A, 40 = 40A, 50 = 50A, 63 = 63A
Curve IdentifierB/C/D: Type B (3In-5In), Tipo C (5In-10In), Tipo D (10In-14In)
  1. Classified List of Full Series Models
  2. 1P+N (Most Commonly Used)
    Tripping CurveCapacità di interruzioneCorrente nominaleModello
    Type BStandard Type2A/4A/6A/10A/16A/20A/25A/32A/40AA9P22602/A9P22604/A9P22606/A9P22610/A9P22616/A9P22620/A9P22625/A9P22632/A9P22640
    Type N2A/4A/6A/10A/16A/20A/25A/32A/40AA9P42602/A9P42604/A9P42606/A9P42610/A9P42616/A9P42620/A9P42625/A9P42632/A9P42640
    Tipo CStandard Type2A/4A/6A/10A/16A/20A/25A/32A/40A/50A/63AA9P22602/A9P22604/A9P52606/A9P22610/A9P22616/A9P22620/A9P22625/A9P22632/A9P22640/A9P22650/A9P22663
    Type N2A/4A/6A/10A/16A/20A/25A/32A/40A/50A/63AA9P42602/A9P42604/A9P54606/A9P42610/A9P42616/A9P42620/A9P42625/A9P42632/A9P42640/A9P42650/A9P42663
    Tipo DStandard Type10A/16A/20A/25A/32A/40A/50A/63AA9P62610/A9P62616/A9P62620/A9P62625/A9P62632/A9P62640/A9P62650/A9P62663
    Type N10A/16A/20A/25A/32A/40A/50A/63AA9P64610/A9P64616/A9P64620/A9P64625/A9P64632/A9P64640/A9P64650/A9P64663

    2P (Two-pole)

Tripping CurveCapacità di interruzioneCorrente nominaleModello
Tipo CStandard Type6A/10A/16A/20A/25A/32A/40AA9P52206/A9P52210/A9P52216/A9P52220/A9P52225/A9P52232/A9P52240
Type N6A/10A/16A/20A/25A/32A/40AA9P54206/A9P54210/A9P54216/A9P54220/A9P54225/A9P54232/A9P54240
Tipo DStandard Type16A/20A/32A/40AA9P62216/A9P62220/A9P62232/A9P62240
Type N16A/20A/32A/40AA9P64216/A9P64220/A9P64232/A9P64240
  1. 3P (Tripolare)
Tripping CurveCapacità di interruzioneCorrente nominaleModello
Tipo CStandard Type6A/10A/16A/20A/25A/32A/40AA9P52306/A9P52310/A9P52316/A9P52320/A9P52325/A9P52332/A9P52340
Type N6A/10A/16A/20A/25A/32A/40AA9P54306/A9P54310/A9P54316/A9P54320/A9P54325/A9P54332/A9P54340
Tipo DStandard Type16A/20A/32A/40A/50AA9P62316/A9P62320/A9P62332/A9P62340/A9P62350
Type N16A/20A/32A/40A/50AA9P64316/A9P64320/A9P64332/A9P64340/A9P64350
  1. 4P (Four-pole)
Tripping CurveCapacità di interruzioneCorrente nominaleModello
Tipo CStandard Type6A/10A/16A/20A/32A/40AA9P52406/A9P52410/A9P52416/A9P52420/A9P52432/A9P52440
Type N6A/10A/16A/20A/32A/40AA9P54406/A9P54410/A9P54416/A9P54420/A9P54432/A9P54440
  1. 3P+N (Tripolare + Neutral)
Tripping CurveCapacità di interruzioneCorrente nominaleModello
Tipo CStandard Type16A/20A/32A/40AA9P52716/A9P52720/A9P52732/A9P52740
Type N16A/20A/32A/40AA9P54716/A9P54720/A9P54732/A9P54740
Tipo DStandard Type20A/32A/40AA9P62720/A9P62732/A9P62740
Type N20A/32A/40AA9P64720/A9P64732/A9P64740
  1. Key Features and Selection Points
  2. Core Advantages:

1P+N Design: Live wire protection plus synchronous neutral wire switching, suitable for 230V single-phase systems, saving installation space (1 module = 18mm).

Graded Breaking Capacity: Standard type is suitable for terminal distribution, while Type N is suitable for front-end circuits close to distribution transformers.

Tripping Curve Adaptability: Type B (for electronic equipment), Tipo C (for lighting/sockets), Tipo D (for motors/power loads).

  1. Comparison with the Original Model:

The model you queried: A9P52606: 1P+N, 6UN, Tipo C, standard breaking capacity (4.5kA/6kA).

Upgraded Type N version: A9P54606 (breaking capacity upgraded to 6kA/10kA).

Same current with different curves: A9P42606 (Type B), A9P62606 (Tipo D).

  1. Accessory Compatibility: The full series is compatible with Acti9 standard accessories, such as auxiliary contacts (A9A26924) and alarm contacts (A9A26934).
  2. Scenari applicativi tipici
Model ExampleScenario applicativo
A9P52606 (1P+N, 6UN, Tipo C)Residential/commercial lighting circuits, sockets for small electronic devices
A9P54616 (1P+N, 16UN, Tipo C, Type N)Kitchen appliances, air conditioner sockets (requiring higher breaking capacity)
A9P64232 (2P, 32UN, Tipo D, Type N)Power equipment such as single-phase water pumps and compressors
A9P54340 (3P, 40UN, Tipo C, Type N)Industrial equipment such as three-phase fans and small air compressors

 