ACS 310-01E-02A4-2 ABB General-Purpose Inverter

Product Overview & Model Explanation

ACS 310-01E-02A4-2 is a general-purpose inverter from the ABB ACS310 series with single-phase 230 V input and three-phase output. It is mainly designed for variable-torque applications such as fans and pumps, with IP20 protection and C3 EMC filter compatibility.

Model Code Breakdown (ABB ACS310 Naming Convention)

Code意味Description
ACS 310Basic seriesACS310 = general-purpose inverter, optimized for fan & pump variable-torque loads
01EFrame & enclosure01 = Frame R1; E = IP20, no built-in filter (external filter required)
02A4Rated output & 電圧02A = rated output current 2.4 あ (0.37 kW); 4 = voltage class (200–240 V)
2Input phase2 = single-phase input (200–240 V), three-phase 200–240 V output
  1. Core Technical Specifications

2.1 Electrical Data

ItemSpecification
Input powerSingle-phase 200–240 V AC, 50/60 Hz, ±10% tolerance
OutputThree-phase 0–240 V AC, 0–500 Hz, 0.37 kW / 2.4 あ, 150% 過負荷 60 s
Control modeV/f制御 (flux vector optional), built-in PID and PFC (pump/fan control)
Digital I/O2 デジタル入力, 1 リレー出力 (250 V AC/2 A, 30 V DC/2 A)
Analog I/O1 analog input (0–10 V or 4–20 mA), 1 アナログ出力 (0–20 mA)
CommunicationBuilt-in Modbus EIA-485, Modbus RTU supported
EMCCategory C3 (industrial environment), external filter required

2.2 Mechanical Characteristics

ItemSpecification
FrameR1 (132 × 175 × 155 mm, W × H × D)
MountingWall or cabinet mounting, vertical installation; ≥100 mm clearance top & bottom
ProtectionIP20
TemperatureOperating: -10 °C to +40 ℃ (derate above 40 ℃); Storage: -40 °C to +70 ℃
重さ約. 1.5 kg
CoolingNatural convection (no fan)
  1. Key Functions & Applications

3.1 ファン & Pump Special Functions

Built-in multi-pump control (up to 4 pumps), alternation and automatic backup

Pipe cleaning and priming functions for system commissioning and maintenance

Sleep / wake-up function for significant energy saving

Anti-blockage and dry-run protection for pumps

Motor noise smoothing to reduce noise

3.2 代表的な用途

ApplicationSuitable EquipmentKey Benefits
HVAC systemsCentrifugal fans, pumps, cooling tower fans30–50% energy saving, stable, low noise
Water treatmentBooster pumps, submersible pumps, sewage pumpsDry-run protection, multi-pump control
Industrial circuitsCooling pumps, lubrication pumpsLonger service life, lower maintenance
Small machineryConveyors, mixers, small compressorsEasy to use, 費用対効果の高い
  1. Series Models & Alternatives

4.1 ACS310 Series (Frame R1, 200–240 V single-phase)

モデルRated Power定格電流Main DifferenceApplication
ACS310-01E-02A4-20.37 kW2.4 あBasic model小型ファン, micro pumps
ACS310-01E-04A7-20.75 kW4.7 あHigher powerSmall/medium fans & pumps
ACS310-01E-07A5-21.5 kW7.5 あHigher powerMedium fans & pumps
ACS310-01E-09A8-22.2 kW9.8 あHigher powerLarge fans & pumps

4.2 Recommended Alternatives

AlternativeMain DifferenceApplication
ACS310-03E-02A4-4Three-phase 380–480 V input, 0.37 kWIndustrial three-phase systems
ACS355-01E-02A4-2Full-featured, built-in EMC filterHigher EMC & functional requirements
ACS580-01-03A3-4ベクトル制御, 180% 過負荷High dynamic & precision control
  1. Accessories & Options
AccessoryType CodeDescription
Control panelCDP312RBasic control and parameter setting
Advanced panelCDP312R-ETHWith Ethernet, remote monitoring
EMC filter3AFE68300909C3 EMC filter for industrial environment
Brake unitACS-BU-01For frequent start/stop and braking
I/O extension3AXD500000387624 から + 2 DO expansion
Comm module3AXD50000038763Profibus-DP interface
  1. インストール & トラブルシューティング

6.1 Installation Notes

  1. Electrical installation

Input must be protected by a circuit breaker and fuse matching 2.4 あ

Output cable: shielded, max. 50 m to prevent motor overvoltage

Separate control wiring from power wiring by ≥100 mm

  1. Mechanical installation

Mount vertically with sufficient ventilation

Derate 1% per °C above 40 ℃

Avoid high vibration, dust, moisture, corrosive gas

6.2 Fault Codes

CodeDescriptionPossible CauseSolution
F001過電流Short circuit, motor overload, wrong settingsCheck wiring, reduce load, reset parameters
F002過電圧High supply voltage, fast decelerationCheck supply, adjust deceleration time
F003不足電圧Low voltage, 位相損失Check input power
F004OvertemperaturePoor ventilation, blocked heatsinkImprove cooling, clean heatsink
F005Motor overloadExcess load, stallReduce load, check motor
F006Earth faultOutput grounded, motor insulation faultCheck cable and motor
  1. Selection & Application Advice
  2. By load type

Fan/pump variable-torque loads: ACS310 series recommended

Constant-torque loads (conveyors, mixers): ACS355 or ACS580

  1. By power

0.37 kW: ACS310-01E-02A4-2

0.37–2.2 kW: ACS310-01E series

> 2.2 kW: ACS310-03E three-phase series

  1. Energy-saving analysis

Fans and pumps can save 30–50% energy with VFD control

Use ABB DriveSize for accurate selection and energy calculation

As an entry-level model of the ABB ACS310 series, the ACS 310-01E-02A4-2 features compact design, easy operation, and fan/pump‑optimized functions, making it an ideal choice for small industrial and commercial applications. For advanced control or higher performance, upgrade to ACS355 or ACS580 series.