CHINT NXBLE-63YH-C20 RCOCB

モデルセグメント説明
Product series code; NXB is the basic series of CHINT miniature circuit breakers, L indicates residual current protection (earth leakage), and E indicates high breaking capacity
63Rated frame current is 63A. The maximum current carrying capacity of this series of circuit breakers is 63A, and C20 is the rated breaking current, which must be less than the frame current
YHSpecial function/specification code; in this CHINT series, YH usually represents the combined function of arc fault detection device (AFDD) + residual current operated circuit breaker (RCCB/RCBO). It can detect arc faults and trip quickly, improving electrical safety
C20C-type tripping curve with a rated current of 20A; C-type tripping curve is suitable for lighting and general power loads (モーターなどの, ファン, 等), with an instantaneous tripping current of 5~10In (In=20A, つまり, 100~200A)

  • 製品詳細

CHINT NXBLE-63YH-C20 is a residual current operated サーキットブレーカー (earth leakage circuit breaker), NXBLEシリーズに属する. It is mainly designed for overload, short-circuit and earth leakage protection in low-voltage distribution lines, and suitable for various scenarios such as industrial and civil applications.

Model Parameter Interpretation

モデルセグメント説明
Product series code; NXB is the basic series of CHINT miniature circuit breakers, L indicates residual current protection (earth leakage), and E indicates high breaking capacity
63Rated frame current is 63A. The maximum current carrying capacity of this series of circuit breakers is 63A, and C20 is the rated breaking current, which must be less than the frame current
YHSpecial function/specification code; in this CHINT series, YH usually represents the combined function of arc fault detection device (AFDD) + residual current operated circuit breaker (RCCB/RCBO). It can detect arc faults and trip quickly, improving electrical safety
C20C-type tripping curve with a rated current of 20A; C-type tripping curve is suitable for lighting and general power loads (モーターなどの, ファン, 等), with an instantaneous tripping current of 5~10In (In=20A, つまり, 100~200A)

コア技術パラメータ (Default Standard Configuration, Subject to Nameplate for Specific Details)

  1. 定格電圧: Single-phase 230V AC, three-phase 400V AC (commonly used in single-phase scenarios)
  2. 定格周波数: 50Hz/60Hz
  3. Residual Current Operation Parameters:

Rated residual operating current (IΔn): commonly 30mA (standard safety value for household/industrial use, which can cut off the power supply quickly to prevent electric shock); 10mA/300mA is available for customization in some models

Operating time: ≤0.1s (instantaneous protection against short-circuit/earth leakage); the operating time of arc fault protection complies with national standard requirements

  1. 遮断容量: 高い遮断容量 (Class E), usually 6kA/10kA (may vary by batch, please check the nameplate), capable of withstanding high current impact during line short-circuit
  2. トリップタイプ: C-type tripping, suitable for conventional loads to avoid non-fault tripping
  3. 取付方法: DINレール取付 (compliant with DIN rail standard, 35mm rail, facilitating batch installation in distribution cabinets)
  4. 極数: Commonly 1P+N, 2P (please check the specific model; C20 specification is mostly 1P+N/2P, suitable for single-phase 220V lines)

アプリケーションシナリオ

Lighting and socket circuits in civil buildings such as residences, office buildings and shopping malls, providing dual protection against electric shock and electrical fire (arc fault + earth leakage)

Small power equipment and control circuits in industrial plants, protecting equipment and the safety of operators

Places sensitive to arc faults (such as old lines and lines around flammable materials); the AFDD function can effectively reduce the risk of fire caused by arcs

Alternative Reference of Corresponding Schneider Model (Selection with the Same Function)

For brand replacement, you can refer to Schneider iDPNa Vigi+ AFDD series, such as iDPNa Vigi+ AFDD C20 30mA. The core parameters are matched: 20定格電流, C-type tripping, 30mA earth leakage protection, arc fault protection. The mounting method and breaking capacity are similar, allowing direct replacement (please check if the pole number, voltage and mounting dimensions are consistent).

設置および使用上の注意事項

  1. 設置前, confirm that the line voltage and current match the parameters of the circuit breaker to avoid faults caused by overload or undervoltage
  2. Wiring must be done according to the marks on the terminals (L for live wire, N for neutral wire, PE for protective earth wire); reverse connection is strictly prohibited for 1P+N models
  3. 定期テスト: を押します。 “テスト” button of the circuit breaker once a month to check whether the earth leakage/arc protection function is normal
  4. Avoid use in humid, dusty and corrosive environments, which may affect the service life and operation reliability of the circuit breaker
  5. Cut off the upper-level power supply before replacement; live operation is strictly prohibited

一般的な障害のトラブルシューティング

故障現象Troubleshooting Direction
頻繁なトリップ1. 過負荷 (例えば, starting multiple high-power devices at the same time); 2. Line leakage (insulation damage, dampness); 3. Arc fault (line aging, loose joints); 4. Circuit breaker itself failure (test button invalid, need replacement)
No Tripping1. Damaged test button; 2. Residual current protection module failure; 3. Wrong wiring (例えば, neutral wire not connected)

Parameter Comparison Table Between CHINT NXBLE-63YH-C20 and Corresponding Schneider Model

To facilitate your direct procurement and replacement, the following is a complete parameter comparison between CHINT NXBLE-63YH-C20 (1P+N/2P) and Schneider iC65N Vigi+ C20 (1P+N model: A9D65140; 2P model: A9D65240), covering core technical indicators and application compatibility.

パラメータのカテゴリCHINT NXBLE-63YH-C20Schneider iC65N Vigi+ C20Replacement Compatibility
基本情報
Product ModelNXBLE-63YH-C20 (1P+N/2P)1P+N: A9D65140完全な互換性
2P: A9D65240
製品シリーズNXBLE Series (upgraded replacement for DZ47LE)Acti9 iC65 SeriesBoth are mainstream series for terminal power distribution
製品タイプResidual current operated circuit breaker (earth leakage MCB)Residual current operated circuit breaker (earth leakage MCB)Consistent Function
コアの電気パラメータ
極数1P+N / 2P1P+N / 2PFully Matched
定格電流 (で)20あ (C-curve)20あ (C-curve)Completely Consistent
トリッピングカーブC-type (instantaneous tripping 5~10 In)C-type (instantaneous tripping 5~10 In)Completely Consistent
遮断容量 (アイコン)6の (YH mark indicates high breaking capacity)6の (N mark indicates standard breaking capacity)Fully Matched
定格残留動作電流 (IΔn)30ミリアンペア (Type AC)30ミリアンペア (Type A, compatible with Type AC leakage)Functionally Compatible
Leakage Operating Time≤0.1s (safety standard for electric shock protection)≤0.1s (compliant with IEC/GB standards)Completely Consistent
定格使用電圧AC230V/400VAC230V/400VCompletely Consistent
定格絶縁電圧400V400VCompletely Consistent
Physical and Installation Parameters
取付方法35mm DIN rail mounting35mm DIN rail mounting完全な互換性
配線方法Top-in bottom-out (horizontal/vertical mounting available)Top-in bottom-out (standard DIN mounting)Consistent Operation
保護クラスIP20 (finger protection)IP20 (IP40 for front side, IP20 for terminals)Suitable for distribution box application
Width Dimension1P+N: 36mm1P+N: 36mmConsistent dimensions, enabling direct replacement
2P: 72mm2P: 72mm
Standards and Certifications
経営陣の基準GB 10963.1, GB 13955IEC 60898, GB 10963.1, GB 13955Both comply with national standards and are applicable in China
認証CCC CertificationCCC, CE認証Both meet domestic application requirements
Special Functions and Maintenance
Test FunctionEquipped with TEST button (monthly test required)Equipped with TEST button (monthly test required)Consistent Operation
TerminalScrew tightening, suitable for 1.5~6mm² wiresScrew tightening, suitable for 1.5~6mm² wiresCompatible with the same wire diameter
動作温度-25℃~+40℃-25℃~+40℃Consistent operating environment

Key Precautions for Replacement

  1. Pole Number Matching: Confirm whether the original circuit is 1P+N or 2P, and select the corresponding Schneider model with the same pole number
  2. Leakage Type: Schneider adopts Type A earth leakage protection (compatible with Type AC), while CHINT uses Type AC. Type A has a wider application range, and replacement is risk-free
  3. Wiring Distinction: For 1P+N models, strictly distinguish between neutral wire (N) and live wire (L); reverse connection is prohibited
  4. 設置スペース: The two models have the same width dimension and can directly replace the original installation position

調達のご提案

For cost optimization: Choose CHINT NXBLE-63YH-C20 with higher cost performance

For brand consistency: Choose Schneider iC65N Vigi+ C20 with better compatibility with Schneider systems

For inventory replacement: The two models can be directly interchanged without modifying the circuit design or wiring method