パラメータValueDescription
極数2PTwo-pole design, protecting both the positive and negative poles of the circuit simultaneously
定格電流6あMaximum current for normal operation
Tripping CharacteristicタイプCStandard tripping curve with an instantaneous tripping range of 8.5In 20%
定格電圧125V DCSuitable for 125V DC systems
遮断容量6のMaximum short-circuit current that can be safely interrupted at 125V DC
取付方法DIN Rail MountingStandard 35mm rail mounting
Product ModelA9N22423Schneider internal part number

  • 製品詳細

C65N-DC/2P-C6A is a miniature circuit breaker specifically designed for DC systems by Schneider Electric (Acti9 series). The detailed parameters are as follows:

パラメータValueDescription
極数2PTwo-pole design, protecting both the positive and negative poles of the circuit simultaneously
定格電流6あMaximum current for normal operation
Tripping CharacteristicタイプCStandard tripping curve with an instantaneous tripping range of 8.5In 20%
定格電圧125V DCSuitable for 125V DC systems
遮断容量6のMaximum short-circuit current that can be safely interrupted at 125V DC
取付方法DIN Rail MountingStandard 35mm rail mounting
Product ModelA9N22423Schneider internal part number

Working Principle & 特徴

The C65N-DC series is a circuit breaker dedicated to DC systems, featuring the following characteristics:

  1. Arc Extinguishing System: Equipped with a special arc extinguishing device designed specifically for DC circuits, effectively quenching DC arcs (DC arcs are more difficult to extinguish than AC arcs).
  2. トリップ特性:

Type C Curve: Suitable for protection of general loads and distribution lines, with an instantaneous tripping current of approximately 51A (8.5×6A).

Thermal-Magnetic Tripping: Integrates dual protection functions of overload protection (thermal protection) および短絡保護 (magnetic protection).

  1. Structural Features:

Compact design with a depth of only 68mm, saving installation space.

Mechanical service life of up to 20,000 operations, ensuring high reliability.

Protection class IP20 (for the unit itself) / IP40 (配電ボックスに設置する場合), providing dust and electric shock protection.

アプリケーションシナリオ

This circuit breaker is suitable for various DC power supply systems:

産業オートメーション: DC motor control, PLC control systems.

New Energy Sector: Solar inverter output protection, エネルギー貯蔵システム.

Communication Equipment: DC-powered devices such as base stations and switches.

Rail Transit: Vehicle auxiliary power supply systems.

Marine Electrical Systems: DC distribution systems.

Typical Application: Protecting DC loads below 6A, such as sensors, small controllers, communication modules, 等.

Selection & Usage Notes

  1. Voltage Matching: Must be used with 125V DC systems; not applicable for AC systems.
  2. Current Selection:

The rated current (6あ) should be greater than the maximum operating current of the circuit.

Consider load starting current: Type C curve allows short-term overloads (例えば, motor startup).

  1. Pole Number Selection: The 2P structure disconnects both positive and negative poles simultaneously, providing safer circuit isolation.