Schneider Electric MCB A9P52606

Schneider Electric A9P52606 is a miniature circuit breaker (MCB) of the Acti9 iC40 series, featuring 1P+N pole configuration, 6A rated current, and C-type tripping curve. It is designed for overload and short-circuit protection of conventional distribution circuits such as lighting and socket systems, with a rated breaking capacity of 6kA (IEC 60947‑2)/4.5の (EN 60898). It adopts DIN rail mounting and has an IP20 protection rating.

  1. Model Interpretation
ItemDetails
モデルA9P52606
SeriesActi9 iC40
Type小型サーキットブレーカー (MCB)
Pole Configuration1P+N (1 protective pole, N pole for switching only)
定格電流6あ
Tripping CurveタイプC
遮断容量6の (IEC 60947‑2), 4.5の (EN 60898‑1)
Mounting MethodDIN Rail
保護等級IP20
  1. コア技術パラメータ
パラメータValueStandard
Rated Operational Voltage (うえ)230V AC 50/60HzEN/IEC 60947‑2
定格電流 (で)6あEN/IEC 60947‑2
Tripping CharacteristicタイプC (instantaneous tripping at 5In‑10In)EN/IEC 60898‑1
Ultimate Breaking Capacity (Icu)6の (230Vと)EN/IEC 60947‑2
Service Breaking Capacity (Icn)4.5の (230Vと)EN/IEC 60898‑1
Rated Impulse Withstand Voltage (Uimp)4kVEN/IEC 60947‑2
Overvoltage CategoryEN/IEC 60947‑2
汚染度3EN/IEC 60947‑2
動作温度-25℃~70℃EN/IEC 60947‑2
電気的寿命20,000 operationsEN/IEC 60947‑2
Mechanical Life20,000 operationsEN/IEC 60947‑2
寸法 (W×D×H)1 module (18mm) × 44mm × 91mmSchneider Electric Technical Manual
Neutral Pole PositionLeft SideSchneider Electric Technical Manual
Tripping Unit TypeThermal-magneticSchneider Electric Technical Manual
  1. 機能的な特徴
  2. 1P+N Design: Live wire protection plus synchronous neutral wire switching, suitable for single-phase distribution systems, with clear wiring and convenient maintenance.
  3. Type C Tripping Curve: Suitable for conventional loads such as lighting and sockets, balancing overload time-delay and short-circuit instantaneous tripping, with strong resistance to inrush current.
  4. High Breaking Capacity: 6の (IEC 60947‑2)/4.5の (EN 60898‑1), capable of handling severe short-circuit faults and ensuring distribution safety.
  5. Standard Mounting: DIN rail mounting with 1-module width, saving switchgear space, and compatible with Acti9 series accessories (例えば, auxiliary contacts, alarm contacts).
  6. 環境適応力: IP20 protection rating, resistant to temperatures ranging from -25℃ to 70℃, meeting the requirements of industrial and civil distribution environments.
  7. Application Scope

Overload and short-circuit protection for single-phase distribution circuits of lighting, ソケット, small motors, 等, in commercial buildings and industrial plants.

Places with high requirements for power supply reliability, such as office buildings, hotels, and hospitals.

Compatible with Acti9 series distribution boxes, used in scenarios such as terminal power distribution and branch circuit protection.

  1. Selection Recommendations
  2. ロードマッチング: Type C curve is suitable for non-inductive loads (例えば, lighting, ソケット); avoid selecting Type D (for power loads) or Type B (for electronic equipment) curves.
  3. Circuit Matching: With a rated current of 6A, it is suitable for 1.5mm² copper core cables (long-term current-carrying capacity ≥ 10A), and the circuit length should be ≤ 100m.
  4. 遮断容量: The 6kA breaking capacity is suitable for terminal distribution; the front-end should be equipped with molded case circuit breakers with higher breaking capacity (例えば, 15kA and above).
  5. Accessory Selection: According to monitoring requirements, select accessories such as auxiliary contacts (例えば, A9A26924) and alarm contacts (例えば, A9A26934).
  6. トラブルシューティング
Fault PhenomenonPossible CausesTroubleshooting Methods
頻繁なトリップOverload, line grounding/short-circuit, mismatched tripping curveCheck load current and insulation resistance; replace MCB with a matching tripping curve
Failure to CloseUnreset tripping mechanism, line short-circuit, contact ablationManually reset the trip lever, locate the short-circuit point, replace damaged contacts
Excessive Temperature RiseLoose wiring, contact oxidation, high ambient temperatureTighten wiring terminals, polish contacts, improve ventilation and heat dissipation
Insufficient Breaking CapacityLack of front-end protection, excessive short-circuit current in the lineUpgrade front-end protection, select MCB with higher breaking capacity
  1. Alternative Solutions

Intra-series Alternatives: A9P52610 (1P+N, 10あ, タイプC), A9P52616 (1P+N, 16あ, タイプC), 等, maintaining mounting and accessory compatibility.

Cross-series Alternatives: Schneider Electric IDPN series (例えば, A9D18606, 1P+N, 6あ, タイプC) or ABB S200 series (例えば, S201M‑C6, 1P+N, 6あ, タイプC). It is necessary to verify the matching of mounting dimensions and breaking capacity.

Complete Guide to Other Models of Schneider Electric Acti9 iC40 Series

Schneider Electric Acti9 iC40 series is a miniature circuit breaker (MCB) specially designed for single-phase/three-phase distribution systems. With 1P+N as the core product, it also provides multiple pole configurations including 2P, 3P, 4P, and 3P+N. The tripping curves cover Type B/C/D, and the breaking capacity is divided into standard type (4.5kA Icn/6kA Icu) and Type N (6kA Icn/10kA Icu), with rated current covering the full range of 1A~63A. The following is a structured and complete list of models:

  1. Model Naming Rules (A9PXXXXXX)
PositionCodeMeaning
1-2A9Acti9 Series Identifier
3PExclusive Code for iC40 Series
42-4遮断容量: 2 = Standard Type (4.5kA/6kA), 4 = Type N (6kA/10kA)
56/2/3/4/7Pole Configuration: 6 = 1P+N, 2 = 2P, 3 = 3P, 4 = 4P, 7 = 3P+N
6-701~63定格電流: 01 = 1A, 02 = 2A, 04 = 4A, 06 = 6A, 10 = 10A, 16 = 16A, 20 = 20A, 25 = 25A, 32 = 32A, 40 = 40A, 50 = 50A, 63 = 63A
Curve IdentifierB/C/D: Type B (3In-5In), タイプC (5In-10In), タイプD (10In-14In)
  1. Classified List of Full Series Models
  2. 1P+N (Most Commonly Used)
    Tripping Curve遮断容量定格電流モデル
    Type BStandard Type2A/4A/6A/10A/16A/20A/25A/32A/40AA9P22602/A9P22604/A9P22606/A9P22610/A9P22616/A9P22620/A9P22625/A9P22632/A9P22640
    タイプN2A/4A/6A/10A/16A/20A/25A/32A/40AA9P42602/A9P42604/A9P42606/A9P42610/A9P42616/A9P42620/A9P42625/A9P42632/A9P42640
    タイプCStandard Type2A/4A/6A/10A/16A/20A/25A/32A/40A/50A/63AA9P22602/A9P22604/A9P52606/A9P22610/A9P22616/A9P22620/A9P22625/A9P22632/A9P22640/A9P22650/A9P22663
    タイプN2A/4A/6A/10A/16A/20A/25A/32A/40A/50A/63AA9P42602/A9P42604/A9P54606/A9P42610/A9P42616/A9P42620/A9P42625/A9P42632/A9P42640/A9P42650/A9P42663
    タイプDStandard Type10A/16A/20A/25A/32A/40A/50A/63AA9P62610/A9P62616/A9P62620/A9P62625/A9P62632/A9P62640/A9P62650/A9P62663
    タイプN10A/16A/20A/25A/32A/40A/50A/63AA9P64610/A9P64616/A9P64620/A9P64625/A9P64632/A9P64640/A9P64650/A9P64663

    2P (Two-pole)

Tripping Curve遮断容量定格電流モデル
タイプCStandard Type6A/10A/16A/20A/25A/32A/40AA9P52206/A9P52210/A9P52216/A9P52220/A9P52225/A9P52232/A9P52240
タイプN6A/10A/16A/20A/25A/32A/40AA9P54206/A9P54210/A9P54216/A9P54220/A9P54225/A9P54232/A9P54240
タイプDStandard Type16A/20A/32A/40AA9P62216/A9P62220/A9P62232/A9P62240
タイプN16A/20A/32A/40AA9P64216/A9P64220/A9P64232/A9P64240
  1. 3P (Three-pole)
Tripping Curve遮断容量定格電流モデル
タイプCStandard Type6A/10A/16A/20A/25A/32A/40AA9P52306/A9P52310/A9P52316/A9P52320/A9P52325/A9P52332/A9P52340
タイプN6A/10A/16A/20A/25A/32A/40AA9P54306/A9P54310/A9P54316/A9P54320/A9P54325/A9P54332/A9P54340
タイプDStandard Type16A/20A/32A/40A/50AA9P62316/A9P62320/A9P62332/A9P62340/A9P62350
タイプN16A/20A/32A/40A/50AA9P64316/A9P64320/A9P64332/A9P64340/A9P64350
  1. 4P (Four-pole)
Tripping Curve遮断容量定格電流モデル
タイプCStandard Type6A/10A/16A/20A/32A/40AA9P52406/A9P52410/A9P52416/A9P52420/A9P52432/A9P52440
タイプN6A/10A/16A/20A/32A/40AA9P54406/A9P54410/A9P54416/A9P54420/A9P54432/A9P54440
  1. 3P+N (Three-pole + Neutral)
Tripping Curve遮断容量定格電流モデル
タイプCStandard Type16A/20A/32A/40AA9P52716/A9P52720/A9P52732/A9P52740
タイプN16A/20A/32A/40AA9P54716/A9P54720/A9P54732/A9P54740
タイプDStandard Type20A/32A/40AA9P62720/A9P62732/A9P62740
タイプN20A/32A/40AA9P64720/A9P64732/A9P64740
  1. Key Features and Selection Points
  2. Core Advantages:

1P+N Design: Live wire protection plus synchronous neutral wire switching, suitable for 230V single-phase systems, saving installation space (1 module = 18mm).

Graded Breaking Capacity: Standard type is suitable for terminal distribution, while Type N is suitable for front-end circuits close to distribution transformers.

Tripping Curve Adaptability: Type B (for electronic equipment), タイプC (for lighting/sockets), タイプD (for motors/power loads).

  1. Comparison with the Original Model:

The model you queried: A9P52606: 1P+N, 6あ, タイプC, standard breaking capacity (4.5kA/6kA).

Upgraded Type N version: A9P54606 (breaking capacity upgraded to 6kA/10kA).

Same current with different curves: A9P42606 (Type B), A9P62606 (タイプD).

  1. Accessory Compatibility: The full series is compatible with Acti9 standard accessories, such as auxiliary contacts (A9A26924) and alarm contacts (A9A26934).
  2. 典型的なアプリケーションシナリオ
Model ExampleApplication Scenario
A9P52606 (1P+N, 6あ, タイプC)Residential/commercial lighting circuits, sockets for small electronic devices
A9P54616 (1P+N, 16あ, タイプC, タイプN)Kitchen appliances, air conditioner sockets (requiring higher breaking capacity)
A9P64232 (2P, 32あ, タイプD, タイプN)Power equipment such as single-phase water pumps and compressors
A9P54340 (3P, 40あ, タイプC, タイプN)Industrial equipment such as three-phase fans and small air compressors

 

前へ:

次:

返信を残す