위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

ABB ESB20-20N-06 contactor - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

접촉기/

ABB ESB20-20N-06 접촉기

ABB ESB20-20N-06 Technical Analysis Report This is a 2-pole, 20에이, 2아니요, 230V AC/DC universal coil modular installation contactor, suitable for single-phase load control in residential and industrial environments. It features silent operation, low power consumption, and integrated overvoltage protection, with a width of only 18mm and standard 35mm DIN rail mounting. Order code: 1SBE121111R0620. 모델 ...

  • 제품 세부정보

ABB ESB20-20N-06 Technical Analysis Report

This is a 2-pole, 20에이, 2아니요, 230V AC/DC universal coil modular installation 접촉기, suitable for single-phase load control in residential and industrial environments. It features silent operation, low power consumption, and integrated overvoltage protection, with a width of only 18mm and standard 35mm DIN rail mounting. Order code: 1SBE121111R0620.

  1. Model Breakdown
모델 세그먼트설명
ESBProduct family: ABB ESB series building / installation contactors
20정격전류: 20에이 (AC-1 duty)
20Main contact configuration: 2 아니요, 0 NC
NFamily identifier: Standard ESB..N installation contactor (vs. EN..N with manual switch)
6Coil voltage code: 230V AC/DC universal
  1. Core Specifications

Electrical Data

메모
Rated operational current (AC-1)20에이Resistive load
Rated operational power (AC-7a, 230다섯)4.6kWSingle-phase motor load
Rated operational current (AC-3, 230다섯)9에이Single-phase motor load
Rated insulation voltage (우이)400다섯IEC compliant
Rated impulse withstand voltage (음)6kVIEC compliant
Coil voltage230V AC/DCUniversal, no polarity required
Coil powerInrush: ~12VA/10WLow-power, energy-saving design
Sealed: ~2VA/2W
Control circuit frequency50/60헤르츠Universal range

Mechanical & Environmental Data

메모
Number of poles22 main circuits
Contact configuration2아니요 + 0NCNo auxiliary contacts
Mechanical durability1,000,000 운영High endurance
Electrical durability (AC-7a/7b)150,000 운영IEC 60947-4-1 compliant
너비18mmModular, space-saving
Mounting35mm DIN railStandard mounting
Operating temperature-25°C ~ +55°CWide temperature range
Storage temperature-40°C ~ +85°CHigh-reliability design
Protection degreeIP20Finger-safe, suitable for distribution boards
  1. 기능 설명
  2. Universal coil technology: AC/DC universal coil, no AC/DC distinction, flexible installation, completely silent and vibration-free operation.
  3. Integrated overvoltage protection: Built-in overvoltage suppression in control circuit, improves system reliability and service life.
  4. 모듈형 디자인: Only 18mm wide, fully compatible with other modular DIN rail components, saves cabinet space.
  5. Accessory compatibility: Supports standard accessories (보조 접점, mechanical interlocks, 등.), tool-free plug-and-play installation.
  6. Safety design: Complies with EN/IEC/UL standards, provides reliable electrical isolation for personnel and equipment safety.
  7. Wide application: Suitable for controlling electric heaters, hot water systems, pump/fan motors, lighting and other single-phase loads.
  8. 선택 권장 사항

Suitable Applications

Lighting, heating, ventilation control in residential and commercial buildings

Single-phase motor control (pumps, 팬) for small industrial equipment

Noise-sensitive environments (hospitals, offices, homes)

Space-limited distribution boards / control cabinets

Selection Criteria

  1. Load type matching:

Resistive load (AC-1): Use 20A rated current directly

Motor load (AC-7a/7b): Recommended ≤9A (4.6kW) at 230V single-phase

Inductive load: Derating or surge suppressor recommended

  1. Coil voltage selection:

Match control system supply (230V AC/DC)

Other voltages available: ESB20-20N-01 (24다섯), ESB20-20N-04 (110다섯)

  1. Contact configuration:

This model: 2아니요, suitable for two independent circuits

For NC contacts: ESB20-02N series (2NC)

For auxiliary contacts: Add auxiliary contact modules

  1. Environmental conditions:

Derate above +40°C ambient temperature

Extra protection required in humid or corrosive environments

  1. 설치 참고 사항

Pre-Installation

Verify model matches order, inspect for physical damage

Confirm coil voltage matches control supply

Prepare standard 35mm DIN rail and suitable terminals

Installation Procedure

Clip contactor firmly onto 35mm DIN rail

Wire main and control circuits per diagram; coil is non-polarized

Terminal torque: 2.5N·m (conductor: 0.5–2.5mm²)

Accessories clip directly onto top/side without tools

안전

Isolate and verify voltage-free before installation

Separate main and control wiring to avoid interference

Ensure adequate ventilation to prevent overheating

Maintain ≥5mm clearance around contactor for heat dissipation

Commissioning & Maintenance

Check wiring before first energization

Test contactor operation for correct switching and no abnormal noise

Inspect contacts and terminal tightness regularly (at least annually)

  1. 대체 모델

Same-Series Alternatives

모델DifferenceApplication
ESB20-20N-0124V AC/DC coilLow-voltage control systems
ESB20-20N-04110V AC/DC coil110V control systems
ESB20-02N-062NC configurationApplications requiring normally closed contacts
EN20-20N-06With manual operatorEmergency manual control

Upgraded Alternatives

모델UpgradeApplication
ESB25-20N-0625A rated currentHigher load requirements
ESB40-40N-064-폴, 40에이Three-phase or higher current
ABB AF seriesIndustrial contactorsHeavy-duty industrial environments

ABB ESB20-20N-06 is a compact, high-performance installation contactor. With silent operation, universal coil, low power consumption and modular design, it is an ideal solution for single-phase load control in residential and industrial applications. Proper selection, installation and maintenance ensure long-term reliable performance and safe, efficient control for electrical systems.

ABB Contactor Standard Selection Procedure

(Industrial & Building, for sales / quotation / design)

Using ESB (building) and AF/A (industrial) as examples – 8-step precise selection ready for proposals and quotations.

  1. Define Application & Product Family

Building / 주거용 / Distribution board: Lighting, heating, pumps, 팬, small motors → ESB/EN series (silent, DIN 레일, narrow width)

Industrial / Equipment / Control cabinet: Fans, pumps, 압축기, motor main circuits → AF/A series (wide voltage, long life, heavy-duty)

  1. Determine Load Category (Critical for Derating)

Per IEC 60947 utilization categories:

AC-1: Resistive loads (heaters, 조명) → use rated current directly

AC-3: Squirrel-cage motor DOL (most common industrial) → motor current ≤ contactor rated current

AC-7a/7b: Building small motors, 팬, pumps → use building contactor rated values

  1. Calculate Operating Current & Rated Capacity
  2. Determine current from power / voltage
  3. Allow 1.1–1.25x safety margin (inrush, continuous duty)
  4. Select corresponding rated current (즉) from ABB catalog

예: 230V single-phase 2kW heater ≈ 8.7A → ESB20-20N is sufficient

  1. Select Number of Poles

1피: Single-phase, single circuit

2피: Single-phase, double-pole (L+N switching, building standard)

3피: Three-phase motors / industrial (most common)

4피: Three-phase + N or double-break

  1. Select Coil Voltage & 유형
  2. Control voltage: 24다섯, 110다섯, 230다섯, 400다섯, 등.
  3. Coil type:

Building: AC/DC universal coil (ESB series, non-polar, silent)

Industrial: Wide-range coil (AF series, stable at 85–110% Un)

  1. Define Auxiliary Contact Requirements

내장: From model (20=2NO, 02=2NC)

Expandable: EH series auxiliary contacts (1NO+1NC, 2아니요, 등.)

Used for: Status feedback, interlocking, sequential control

  1. Environmental & Special Requirements

고도 >1000m, temperature >40°C → derate or upsize

Silent requirement (residential/office): Must use ESB silent type

Protection: IP20 normally sufficient for panel mounting

Mechanical interlock / reversing: Use dedicated interlock accessories

  1. Final Verification: 모델 + Certifications
  2. Confirm full model: family–current–contacts–coil

예: ESB20-20N-06

  1. Verify certifications: CCC, IEC, RoHS
  2. Confirm mounting: 35mm DIN rail / screw mounting

Simplified Selection Mnemonic

  1. Choose family by application
  2. Choose duty by load type
  3. Calculate current with margin
  4. Confirm poles and coil voltage
  5. Add aux contacts for control
  6. Check environment and derate
  7. Verify model for final list

이전:

답장을 남겨주세요

메시지를 남겨주세요