PSR30-600-70 is a member of ABB’s Compact Range soft starter series with the product ID 1SFA896109R7000. It adopts 2-phase control technology and achieves smooth motor starting and stopping via voltage ramping, suitable for the soft start control of three-phase asynchronous motors.
- Model Designation Explanation
| 모델 세그먼트 | 의미 |
| PSR | Identifier for Compact Range soft starter series |
| 30 | Rated maximum operating current 30A |
| 600 | Main circuit operating voltage range 208~600V AC |
| 70 | Control circuit voltage range 100~240V AC 50/60Hz |
III. Core Specification Parameters
| 매개변수 | 값 |
| 정격 작동 전류 | 30에이 |
| Main Circuit Voltage | 208~600V AC 50/60Hz |
| 제어 회로 전압 | 100~240V AC 50/60Hz |
| 적용 가능한 모터 전력 | 240다섯: 10HP(7.5kW); 480다섯: 20HP(15kW); 600다섯: 25HP(18.5kW) |
| Starting Method | Voltage ramp start (adjustable initial voltage 40~70%) |
| Stopping Method | Voltage ramp stop |
| 제어 방법 | 2-phase control |
| 보호 등급 | IP20 |
| 장착 방법 | DIN 레일 장착 |
| 치수 (W脳H脳D) | 45mm * 160mm *128mm |
| 무게 | 대략. 2.00LBS(0.91kg) |
| 터미널 유형 | 나사식 터미널 |
| Starting Frequency | 20 횟수/시간 (4*Ie for 6 seconds continuously) |
| Built-in Relay | Run signal relay, Top of Ramp (TOR) output signal |
- 기능적 특징
- Smooth Start and Stop: Significantly reduces mechanical and electrical shocks during motor starting through voltage ramp control, extending equipment service life.
- Comprehensive Protection Functions:
과부하 보호
Phase loss protection
Overheating protection
단락 보호
Phase reversal protection
Overvoltage/undervoltage protection
- 컴팩트한 디자인: Narrow body design (only 45mm wide) saves control cabinet space.
- 쉬운 설치: Standard DIN rail mounting with connection kits for easy connection to ABB manual motor starters.
- Built-in Signal Relay: Provides run status and Top of Ramp (TOR) signal output for convenient system integration.
- Advanced Algorithm: Eliminates DC components and delivers excellent starting performance.
- 응용 시나리오
Pump loads such as water pumps and fans
Industrial machinery including compressors and conveyors
General industrial applications requiring smooth starting and shock reduction
Occasions that need basic motor protection functions
- 선택 참고
The PSR series soft starters cover a rated current range of 3~45A, with optional control voltages of 24VDC or 100~240VAC, suitable for applications with moderate starting performance requirements and limited space. For more advanced functions (예를 들어, 토크 제어, communication functions), ABB PSS (Universal Range) or PST (Intelligent Range) series soft starters are recommended.
Model Reference for ABB Soft Starter PSR30-600-70
- 같은 시리즈 (PSR) Model Reference
The PSR series is ABB’s compact soft starter with 2-phase control technology, offering two control voltage options: 100-240뷔와 (suffix 70) and 24V AC/DC (suffix 81), with a rated current of 3~105A. The following are related models in the same series as PSR30-600-70:
| 모델 | 정격전류 | 제어 전압 | 적용 가능한 전력 (400다섯) | Product ID | 비고 |
| PSR25-600-70 | 25에이 | 100-240뷔와 | 15kW | 1SFA896108R7000 | One specification smaller than PSR30 |
| PSR30-600-70 | 30에이 | 100-240뷔와 | 18.5kW | 1SFA896109R7000 | Reference model |
| PSR30-600-81 | 30에이 | 24V AC/DC | 18.5kW | 1SFA896109R8100 | Different control voltage |
| PSR37-600-70 | 37에이 | 100-240뷔와 | 22kW | 1SFA896110R7000 | One specification larger than PSR30 |
| PSR45-600-70 | 45에이 | 100-240뷔와 | 30kW | 1SFA896111R7000 | For higher power adaptation |
Full PSR Series Current Coverage
PSR3→PSR6→PSR9→PSR12→PSR16→PSR25→PSR30→PSR37→PSR45→PSR60→PSR72→PSR85→PSR105
- Corresponding Models in Other ABB Series
ABB soft starters include 4 major series with different positioning. The following are alternative models matching the function/power of PSR30-600-70:
| 시리즈 | 모델 | 정격전류 | Main Features | 응용 시나리오 |
| PSE (Easy Range) | PSE30-600-70 | 30에이 | 1.57 times current limit adjustment, built-in bypass, more comprehensive protection | Higher starting performance requirements, need for flexible current limiting |
| PSS (Universal Range) | PSS30-600-70 | 30에이 | Torque control, multiple starting modes, communication functions | Complex industrial applications, need for remote monitoring |
| PSTX (Intelligent Range) | PSTX30-600-70 | 30에이 | Full digital control, LCD display, 17 languages, dynamic braking | High-end applications, need for precise control and diagnosis |
Core Difference Comparison of Series
| 특징 | PSR Series | PSE Series | PSS Series | PSTX Series |
| 제어 방법 | 2-phase control | 3-phase control | 3-phase control | 3-phase control |
| Starting Mode | Voltage ramp | Voltage ramp + current limit | Voltage ramp + 토크 제어 | Multiple intelligent modes |
| 통신 기능 | 없음 | 선택 과목 | 표준 구성 | 표준 구성 |
| Display Interface | Indicator light | Indicator light | LED display | Full LCD display |
| 보호 기능 | Basic protection | Comprehensive protection | Advanced protection | Complete protection + early warning |
| 가격대 | Economic | Mid-range | Mid-to-high range | 고급형 |
III. Corresponding Models of Competitive Brands
The following are soft starter models of mainstream market brands with equivalent functions to PSR30-600-70 (30에이, 18.5kW/400V):
| 상표 | 모델 | 정격전류 | 적용 가능한 전력 | Main Features |
| 슈나이더 | ATS22D32Q | 32에이 | 18.5kW | Built-in bypass, integrated motor protection, Modbus communication |
| 지멘스 | 3RW3028-1BB14 | 30에이 | 18.5kW | 컴팩트한 디자인, voltage ramp start, fault memory |
| 친트 | NJR2-30 | 30에이 | 18.5kW | Economic type, basic protection functions, simple operation |
| 맛있는 | CDRA30 | 30에이 | 18.5kW | 과전류, 위상 손실, 과열 보호, compact size |
- Selection and Replacement Suggestions
- Intra-series Replacement: Prioritize PSR30-600-81 (24V control) or PSR37-600-70 (higher margin) with the same mounting dimensions and compatible wiring.
- Upgrade Replacement:
For adding current limiting function → select PSE30-600-70
For communication and torque control → select PSS30-600-70
For advanced diagnosis and display → select PSTX30-600-70
- Cross-brand Replacement: Choose products with the same rated current (around 30A) and control voltage (100-240뷔와), and pay attention to confirming differences in mounting dimensions and wiring methods.
- 주요 일치 매개변수: Ensure that rated current ≥ motor rated current, main circuit voltage ≥ supply voltage, and control voltage matches the control system.
접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지