Chint CJX2-0901 is a compact AC 접촉기, mainly used to control the on-off of motors or other loads in industrial and commercial circuits.
- 핵심 기술 매개변수
- 모델 의미
CJX2: 시리즈 코드 (CJ stands for AC Contactor, and X2 is the design serial number).
09: Rated operating current of 9A (AC-3 서비스 카테고리에 따라, it can control a 4kW motor at 380V).
01: Auxiliary contact configuration is 1 평상시 닫혀 있음 (NC) contact, with no normally open (아니요) contacts.
- Electrical Characteristics
코일 전압: Supports multiple AC voltages such as 24V, 36다섯, 48다섯, 110다섯, 220다섯, 240다섯, and 380V. Selection should be based on actual needs (예를 들어, CJX2-0901-220V indicates a coil voltage of 220V).
주요 연락처: 3-pole normally open (3아니요), with a rated insulation voltage of 660V and a conventional heating current of 25A.
보조 연락처: 1 평상시 닫혀 있음 (NC) contact, with a rated current of 10A, which can be used for interlocking of control circuits or signal feedback.
Service Life: Mechanical service life of 10 백만 번, electrical service life of 1 million times under AC-3, 그리고 200,000 times under AC-4 (suitable for high-load switching scenarios).
- Physical Specifications
설치 방법: Supports quick installation on 35mm DIN rails and can also be fixed with screws, saving space and facilitating maintenance.
Dimensions: Approximately 79mm × 44mm × 71mm (length × width × height), with a weight of about 0.32kg.
Wiring Capacity: The main contacts can be connected to 2.5mm² flexible wires or 4mm² rigid wires, and the auxiliary contacts support 1.5mm² wires.
- 일반적인 애플리케이션 시나리오
- 모터 제어
Directly starts three-phase asynchronous motors below 380V/4kW or 220V/2.2kW, suitable for equipment such as fans, 물 펌프, and compressors.
Can be combined with thermal overload relays (예를 들어, NR2, JRS1 series) to form electromagnetic starters, 과부하 보호 제공.
- Industrial Automation
Implements sequential control of equipment in production lines, 예를 들어, controlling the contactor coil through PLC output signals to drive robotic arms or conveyors.
Used in star-delta reduced-voltage starting circuits, cooperating with time relays to achieve smooth starting.
- Power Systems
Serves as a remote control component in power distribution systems, realizing the switching-on and switching-off of circuits by controlling the on-off of the coil, thereby improving power supply reliability.
III. Performance Advantages and Expansion Functions
- 신뢰성 설계
Adopts silver alloy contact material, which has excellent anti-welding and wear-resistant performance, suitable for frequent operation occasions.
The coil has a built-in surge suppressor (external SR2-A series is required), which can reduce electromagnetic interference and protect the control system.
- Modular Expansion
F4 series auxiliary contact blocks can be installed on the top (예를 들어, F4-20: 2 normally open contacts; F4-02: 2 normally closed contacts), and the number of auxiliary contacts can be expanded to a maximum of 4 pairs.
Air time delay heads (F5 series) can be installed on the side to achieve 0.1-180 seconds of energization or de-energization delay functions, meeting the needs of complex timing control.
- Compatibility and Certifications
Compatible with international brands such as Schneider LC1-D09 and Siemens 3TF40, with matching installation dimensions and electrical parameters, facilitating replacement and upgrading.
Has passed certifications such as CCC and CE, complies with GB/T 14048.4 그리고 IEC 60947-4-1 표준, and is suitable for most regions around the world.
- Selection and Usage Recommendations
- Key Selection Points
Select the service category according to the load type: AC-3 is used for normal motor starting, and AC-4 is used for occasions with frequent forward-reverse rotation or braking (derating is required in this case).
The coil voltage must be consistent with the control circuit to avoid coil burnout or incorrect operation of the contactor due to voltage mismatch.
- Installation Precautions
The installation environment temperature should be between -5℃ and +40℃, and high-temperature or humid environments should be avoided to prevent impact on service life.
The main circuit and control circuit should be wired separately to reduce signal interference; during wiring, ensure that the contacts are crimped firmly to prevent heating caused by poor contact.
- Maintenance Recommendations
Regularly clean the oxide layer and dust on the contact surface, check the contact wear condition, and replace the contacts when the wear exceeds 1mm.
Check the coil insulation resistance every 1-2 연령, which should be not less than 1MΩ; if overheating or abnormal noise of the coil is found, troubleshoot in a timely manner.
- Market Price and Purchase Channels
Reference Prices
The 220V coil model is priced at approximately 20-35 RMB per unit (왓츠앱: 0086-13811255435).
The unit price of expansion modules (예를 들어, F4 auxiliary contact blocks) is approximately 3-10 RMB, and that of air time delay heads is approximately 50-100 RMB.
접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

















NH42-63-318x560.png)