친트 NXBLE-63YH-C20 RCOCB

모델 세그먼트설명
다음Product series code; NXB is the basic series of CHINT miniature circuit breakers, L indicates residual current protection (earth leakage), and E indicates high breaking capacity
63Rated frame current is 63A. The maximum current carrying capacity of this series of circuit breakers is 63A, and C20 is the rated breaking current, which must be less than the frame current
YHSpecial function/specification code; in this CHINT series, YH usually represents the combined function of arc fault detection device (인기 없는) + residual current operated circuit breaker (RCCB/RCBO). It can detect arc faults and trip quickly, improving electrical safety
C20C-type tripping curve with a rated current of 20A; C-type tripping curve is suitable for lighting and general power loads (모터와 같은, 팬, 등.), with an instantaneous tripping current of 5~10In (In=20A, 즉., 100~200A)

  • 제품 세부정보

CHINT NXBLE-63YH-C20 is a residual current operated 회로 차단기 (누전 차단기), belonging to the NXBLE series. It is mainly designed for overload, short-circuit and earth leakage protection in low-voltage distribution lines, and suitable for various scenarios such as industrial and civil applications.

Model Parameter Interpretation

모델 세그먼트설명
다음Product series code; NXB is the basic series of CHINT miniature circuit breakers, L indicates residual current protection (earth leakage), and E indicates high breaking capacity
63Rated frame current is 63A. The maximum current carrying capacity of this series of circuit breakers is 63A, and C20 is the rated breaking current, which must be less than the frame current
YHSpecial function/specification code; in this CHINT series, YH usually represents the combined function of arc fault detection device (인기 없는) + residual current operated circuit breaker (RCCB/RCBO). It can detect arc faults and trip quickly, improving electrical safety
C20C-type tripping curve with a rated current of 20A; C-type tripping curve is suitable for lighting and general power loads (모터와 같은, 팬, 등.), with an instantaneous tripping current of 5~10In (In=20A, 즉., 100~200A)

핵심 기술 매개변수 (Default Standard Configuration, Subject to Nameplate for Specific Details)

  1. 정격전압: Single-phase 230V AC, three-phase 400V AC (commonly used in single-phase scenarios)
  2. 정격 주파수: 50Hz/60Hz
  3. Residual Current Operation Parameters:

Rated residual operating current (IΔn): commonly 30mA (standard safety value for household/industrial use, which can cut off the power supply quickly to prevent electric shock); 10mA/300mA is available for customization in some models

Operating time: ≤0.1s (instantaneous protection against short-circuit/earth leakage); the operating time of arc fault protection complies with national standard requirements

  1. 차단 용량: High breaking capacity (Class E), usually 6kA/10kA (may vary by batch, please check the nameplate), capable of withstanding high current impact during line short-circuit
  2. Tripping Type: C형 트리핑, suitable for conventional loads to avoid non-fault tripping
  3. 장착 방법: DIN 레일 장착 (compliant with DIN rail standard, 35mm rail, facilitating batch installation in distribution cabinets)
  4. 극수: Commonly 1P+N, 2피 (please check the specific model; C20 specification is mostly 1P+N/2P, suitable for single-phase 220V lines)

응용 시나리오

Lighting and socket circuits in civil buildings such as residences, office buildings and shopping malls, providing dual protection against electric shock and electrical fire (arc fault + earth leakage)

Small power equipment and control circuits in industrial plants, protecting equipment and the safety of operators

Places sensitive to arc faults (such as old lines and lines around flammable materials); the AFDD function can effectively reduce the risk of fire caused by arcs

Alternative Reference of Corresponding Schneider Model (Selection with the Same Function)

For brand replacement, you can refer to Schneider iDPNa Vigi+ AFDD series, such as iDPNa Vigi+ AFDD C20 30mA. The core parameters are matched: 20A rated current, C형 트리핑, 30mA earth leakage protection, arc fault protection. The mounting method and breaking capacity are similar, allowing direct replacement (please check if the pole number, voltage and mounting dimensions are consistent).

설치 및 사용상의 주의사항

  1. 설치 전, confirm that the line voltage and current match the parameters of the circuit breaker to avoid faults caused by overload or undervoltage
  2. Wiring must be done according to the marks on the terminals (L for live wire, N for neutral wire, PE for protective earth wire); reverse connection is strictly prohibited for 1P+N models
  3. 정기 테스트: 다음을 누르세요. “시험” button of the circuit breaker once a month to check whether the earth leakage/arc protection function is normal
  4. Avoid use in humid, dusty and corrosive environments, which may affect the service life and operation reliability of the circuit breaker
  5. Cut off the upper-level power supply before replacement; 실시간 작업은 엄격히 금지됩니다.

일반적인 오류 문제 해결

결함 현상Troubleshooting Direction
Frequent Tripping1. Load overload (예를 들어, starting multiple high-power devices at the same time); 2. Line leakage (insulation damage, dampness); 3. Arc fault (line aging, loose joints); 4. Circuit breaker itself failure (test button invalid, need replacement)
No Tripping1. Damaged test button; 2. Residual current protection module failure; 3. Wrong wiring (예를 들어, neutral wire not connected)

Parameter Comparison Table Between CHINT NXBLE-63YH-C20 and Corresponding Schneider Model

To facilitate your direct procurement and replacement, the following is a complete parameter comparison between CHINT NXBLE-63YH-C20 (1P+N/2P) and Schneider iC65N Vigi+ C20 (1P+N model: A9D65140; 2P model: A9D65240), covering core technical indicators and application compatibility.

매개변수 카테고리CHINT NXBLE-63YH-C20Schneider iC65N Vigi+ C20교체 호환성
기본정보
제품 모델NXBLE-63YH-C20 (1P+N/2P)1P+N: A9D65140Fully Compatible
2피: A9D65240
제품 시리즈NXBLE 시리즈 (upgraded replacement for DZ47LE)Acti9 iC65 SeriesBoth are mainstream series for terminal power distribution
제품 유형Residual current operated circuit breaker (earth leakage MCB)Residual current operated circuit breaker (earth leakage MCB)Consistent Function
핵심 전기 매개변수
극수1P+N / 2피1P+N / 2피Fully Matched
정격전류 (~ 안에)20에이 (C-curve)20에이 (C-curve)Completely Consistent
트리핑 곡선C형 (instantaneous tripping 5~10 In)C형 (instantaneous tripping 5~10 In)Completely Consistent
차단 용량 (아이콘)6그만큼 (YH mark indicates high breaking capacity)6그만큼 (N mark indicates standard breaking capacity)Fully Matched
정격 잔류 작동 전류 (IΔn)30엄마 (AC형)30엄마 (Type A, compatible with Type AC leakage)Functionally Compatible
Leakage Operating Time≤0.1s (safety standard for electric shock protection)≤0.1s (compliant with IEC/GB standards)Completely Consistent
정격 작동 전압AC 230V/400VAC 230V/400VCompletely Consistent
정격 절연 전압400다섯400다섯Completely Consistent
Physical and Installation Parameters
장착 방법35mm DIN rail mounting35mm DIN rail mountingFully Compatible
배선 방법탑인 바텀아웃 (horizontal/vertical mounting available)탑인 바텀아웃 (standard DIN mounting)Consistent Operation
보호 등급IP20 (finger protection)IP20 (IP40 for front side, IP20 for terminals)Suitable for distribution box application
Width Dimension1P+N: 36mm1P+N: 36mmConsistent dimensions, enabling direct replacement
2피: 72mm2피: 72mm
Standards and Certifications
Executive StandardsGB 10963.1, GB 13955IEC 60898, GB 10963.1, GB 13955Both comply with national standards and are applicable in China
인증CCC CertificationCCC, CE 인증Both meet domestic application requirements
Special Functions and Maintenance
Test FunctionEquipped with TEST button (monthly test required)Equipped with TEST button (monthly test required)Consistent Operation
단말기Screw tightening, suitable for 1.5~6mm² wiresScrew tightening, suitable for 1.5~6mm² wires동일한 와이어 직경과 호환 가능
작동 온도-25°C ~ +40°C-25°C ~ +40°CConsistent operating environment

Key Precautions for Replacement

  1. Pole Number Matching: Confirm whether the original circuit is 1P+N or 2P, and select the corresponding Schneider model with the same pole number
  2. 누설 유형: Schneider adopts Type A earth leakage protection (compatible with Type AC), while CHINT uses Type AC. Type A has a wider application range, and replacement is risk-free
  3. Wiring Distinction: 1P+N 모델의 경우, strictly distinguish between neutral wire (N) 그리고 활선 (엘); 역접속 금지
  4. 설치공간: The two models have the same width dimension and can directly replace the original installation position

Procurement Suggestions

For cost optimization: Choose CHINT NXBLE-63YH-C20 with higher cost performance

For brand consistency: Choose Schneider iC65N Vigi+ C20 with better compatibility with Schneider systems

For inventory replacement: The two models can be directly interchanged without modifying the circuit design or wiring method