위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

Schneider Electric NSX250N‑3P‑160A - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

회로 차단기/

Schneider Electric NSX250N‑3P‑160A

This is a Schneider Electric ComPacT NSX series molded case circuit breaker (MCCB) for power distribution protection. New standard order number: C25N3TM160 Obsolete old order number: LV431832 Compliant with IEC 60947‑2 and GB/T 14048.2 표준. Basic Rated Core Parameters Item Value Type Low‑voltage MCCB for power distribution protection Frame rating 250A Poles 3P (3 극, ...

  • 제품 세부정보

This is a Schneider Electric ComPacT NSX series molded case circuit breaker (MCCB) for power distribution protection.

New standard order number: C25N3TM160

Obsolete old order number: LV431832

Compliant with IEC 60947‑2 and GB/T 14048.2 표준.

  1. Basic Rated Core Parameters
유형Low‑voltage MCCB for power distribution protection
Frame rating250에이
Poles3피 (3 극, all protected)
Rated current In160에이 (continuous at 40℃)
Rated operational voltage Ue690V AC 50/60Hz, suitable for 380V/400V/415V systems
Rated insulation voltage Ui800뷔와
Rated impulse withstand voltage Uimp8kV
빈도50/60헤르츠
Utilization categoryType A (no short‑time delay, general distribution)
Isolation functionCertified isolating function per IEC 60947‑2
  1. Short‑Circuit Breaking Capacity
System VoltageRated ultimate shortircuit breaking capacity IcuRated service shortircuit breaking capacity Ics
415뷔와50그만큼50그만큼 (100% 중환자실, reusable after breaking)
500뷔와36그만큼36그만큼
690뷔와10그만큼10그만큼

Rated short‑time withstand current Icw (1에스): 12kA at 415V AC

  1. TMD Thermal‑Magnetic Release Characteristics

Standard TMD thermal‑magnetic release, LI protection (long‑time overload + instantaneous short‑circuit).

  1. Long‑time overload thermal protection

Ir setting range: 0.7–1×In (112A–160A)

Characteristic: 120–400s at 1.5×Ir; ≤15s at 6×Ir (standard inverse time)

  1. Short‑circuit instantaneous magnetic protection

Instantaneous current Ii: fixed at 1250A

Operating time: ≤20ms

  1. Mechanical & Installation Parameters
치수 (W×H×D)105mm × 161mm × 86mm
Standard mounting centersVertical 125mm × Horizontal 35mm
MountingFixed, front connected; horizontal/vertical, no derating
Wiring capacityUp to 70mm² copper cable / busbar
Mechanical endurance20,000 운영
Electrical endurance10,000 operations at 440V AC, In
Ingress protectionIP40 (body), IP54 (panel‑mounted)
Impact resistanceIK07
Net weight대략. 2.4kg
  1. Environmental & Compliance Parameters

Ambient temperature: -25℃ ~ +70℃; no derating below 40℃

고도: 0–2000m without derating

Pollution degree: 3

Overvoltage category: II

Certifications: CCC, CE, EAC, Marine, 등.

Accessory slots: 5 standard slots for auxiliary, alarm, shunt, undervoltage release, 등.

  1. Expansion & 호환성

Can be fitted with Vigi earth‑leakage modules

Compatible with motor operators for remote control

Can add interlock, position indicator, padlock devices

Top/bottom feed both allowed without performance derating

Replacement & Selection Notes

  1. Old type LV431832 is discontinued; use C25N3TM160 instead.
  2. For electronic release (adjustable short delay / earth fault), upgrade to NSX250N with MicroLogic (2.2/5.0).
  3. Breaking ratings: H (70그만큼), S (100그만큼), based on short‑circuit calculation.
  4. Competitors: ABB Tmax T2, Siemens 3VT250, suitable for cross‑brand replacement.

NSX250N‑3P‑160A Direct Replacement Solutions

Core Matching Rules (100% match required)

Frame rating: 250에이 (do NOT downgrade to 160A frame)

Poles: 3피

정격전류: 160에이

차단 용량: ≥50kA at 415V AC

Release type: thermal‑magnetic (LI characteristic)

Mounting: fixed front connection, matching panel holes

  1. Recommended Replacements

대본 1: Import Brand Direct Replacement

ABB Tmax XT3N250 TMD160/1600 FF 3P

Order No.: 1SDA068266R1

Match: 100%

Frame 250A, 3피, 160에이, TMG thermal‑magnetic

Icu=50kA, Ics=50kA at 415V AC

Identical dimensions and mounting holes

Full accessory compatibility

Application: foreign‑funded plants, export equipment, on‑site repair

Siemens 3VC250N TMA160 3P

Order No.: 3VC2316‑2DA33‑0AA0

Match: 98%

Frame 250A, 3피, 160에이, TMA thermal‑magnetic

50kA at 415V AC

Highly compatible dimensions

Application: Siemens low‑voltage systems

대본 2: Domestic High‑Cost‑Performance Replacement

Changshu Switch CM3‑250H/3300 160A

Match: 99%

Frame 250A, 3피, 160에이, distribution type thermal‑magnetic

Icu=50kA at 415V AC

Compliant with IEC 60947‑2 / GB 14048.2

Application: industrial, building distribution, domestic projects

Chint NM8‑250N/3P 160A

Match: 95%

Frame 250A, 3피, 160에이, thermal‑magnetic

50kA at 415V AC

Application: civil construction, general distribution

  1. 치수 & Parameters Comparison
모델치수 (W×H×D)Mounting Centers중환자실 (415다섯)ReleaseFrame
NSX250N‑3P‑160A105×161×86mm125mm×35mm50그만큼TMD250에이
ABB XT3N250 3P 160A105×161×86mm125mm×35mm50그만큼TMG250에이
Siemens 3VC250N 3P 160A105×160×85mm125mm×35mm50그만큼TMA250에이
CM3‑250H 3P 160A108×162×86mm125mm×35mm50그만큼Thermal‑magnetic250에이

> 메모: ABB XT3N250 matches dimensions and holes 100% – best direct replacement.

  1. Safety Rules for Replacement
  2. No frame downgrade: Do NOT use 160A frame breakers (예를 들어, ABB T2N, NSX160).
  3. Breaking capacity ≥50kA: Do NOT use 36kA / 25kA models.
  4. Release matching: Use distribution‑type thermal‑magnetic only.
  5. Accessory compatibility: Match auxiliary, shunt, 저전압, earth‑leakage modules.
  6. Final Selection Guide

Direct replacement, import, no cabinet modification: ABB XT3N250 TMD160/1600 FF 3P

New project, domestic approval, cost‑effective: Changshu CM3‑250H/3300 160A

Siemens system replacement: Siemens 3VC250N TMA160 3P

이전:

답장을 남겨주세요

메시지를 남겨주세요