Siemens 3WL1N16-1600A ETU45B-G-LCD-3P

Model SeriesMounting Method무게 (kg)Remarks
3WL1116Fixed Type에 대한 45Including ETU45B trip unit
3WL1116Drawout Type에 대한 55Including drawer base and ETU45B trip unit
3WL1216Fixed Type에 대한 56Including ETU45B trip unit
3WL1216Drawout Type에 대한 65Including drawer base and ETU45B trip unit

  • 제품 세부정보

Siemens 3WL1N16-1600A ETU45B-G-LCD-3P is a low-voltage air circuit breaker manufactured by Siemens.

Product Type: It belongs to the 3WL series air circuit breakers and can be used as incoming line, bus tie and feeder circuit breakers in electrical systems for industrial, building and infrastructure applications.

모델 해석: In the model 3WL1N16, “3” represents the product series code, “WL1indicates the No.1 specification of the 3WL series, “N” usually denotes the standard type, 그리고 “16” means the frame size current is 1600A; “1600에이” is the rated current of the circuit breaker; “ETU45Brefers to the model of the electronic trip unit; “Gsignifies the ground fault protection function; “LCDmeans it is equipped with a liquid crystal display; “3Pindicates that the circuit breaker is three-pole.

Technical Features:

Comprehensive Protection Functions: It provides overload protection, 단락 보호, ground fault protection and other functions. The overload protection L (long-time protection) of the electronic trip unit ETU45B allows switching characteristic curves between I²t and I⁴t, and the monitoring function I⁴t characteristic improves the selectivity with downstream circuit breakers and fuses.

Communication and Data Acquisition: It has communication capabilities and can transmit data such as current values, switch status and trip causes to the central computer via standard PROFIBUS DP or MODBUS. It can also cooperate with the Plus measurement function to realize energy data acquisition, facilitating remote monitoring and energy management.

High Adjustability: Protection functions can be set through rotary coding switches or slide switches, and parameters such as overload protection time-delay levels, and characteristic curves of overload and short-time delay short-circuit ranges can be adjusted according to actual requirements.

Display Function: Equipped with an LCD display, it can clearly show trip status, trip causes and other information, which is convenient for fault diagnosis and equipment maintenance.

Appearance and Installation: Adopting a modular design, it is easy to maintain and modify. It can be installed by means of screw mounting or DIN rail mounting, and can be conveniently integrated into electrical systems.

Dimensions of Siemens 3WL1N16-1600A ETU45B-G-LCD-3P

> 메모: The model “33WL1N16is likely a typo; the correct model should be 3WL1116 (Frame Size I) or 3WL1216 (Frame Size II) 1600A 3P ETU45B-G-LCD. In the correct model, “16” indicates a frame size current of 1600A, “3Pmeans three-pole, 그리고 “ETU45B-G-LCDrepresents the electronic trip unit ETU45B with ground fault protection (G) and liquid crystal display (LCD).

  1. Core Dimension Parameters (Unit: mm)

1.1 Frame Size I (3WL1116 Series)

Mounting MethodWidth (여)Height (H)Depth (D)Remarks
Fixed Type320434291Standard depth, excluding the protruding part of the operating mechanism
Drawout Type320434에 대한 450Including the depth of the drawer base, subject to accessory configuration

1.2 Frame Size II (3WL1216 Series)

Mounting MethodWidth (여)Height (H)Depth (D)Remarks
Fixed Type460434291Standard depth, excluding the protruding part of the operating mechanism
Drawout Type460434에 대한 450Including the depth of the drawer base, subject to accessory configuration

1.3 Key Supplementary Instructions

  1. Height Consistency: The standard height of all 3WL series circuit breakers (Frame Size 0/I/II/III) is 434mm, which is the unified design standard of this series.
  2. Depth Difference:

The basic depth of the fixed type is 291mm (Frame Size I/II).

The depth of the drawout type increases by about 160mm (thickness of the drawer base).

If equipped with an extended operating mechanism or other special accessories, the depth may increase further.

  1. Impact of ETU45B-G-LCD: The type of electronic trip unit (ETU45B) and display mode (LCD) have no significant impact on the overall dimensions, and only affect the layout of the front panel of the circuit breaker.
  2. Mounting Hole Dimensions:

Frame Size I: Recommended mounting hole width is 310mm and height is 424mm.

Frame Size II: Recommended mounting hole width is 450mm and height is 424mm.

Mounting Spacing: It is recommended to reserve a heat dissipation space of ≥50mm between adjacent circuit breakers.

  1. Weight Reference
Model SeriesMounting Method무게 (kg)Remarks
3WL1116Fixed Type에 대한 45Including ETU45B trip unit
3WL1116Drawout Type에 대한 55Including drawer base and ETU45B trip unit
3WL1216Fixed Type에 대한 56Including ETU45B trip unit
3WL1216Drawout Type에 대한 65Including drawer base and ETU45B trip unit
  1. Dimension Selection Recommendations
  2. Frame Size Selection:

Frame Size I (3WL1116): Breaking capacity is 55kA, suitable for conventional industrial and building power distribution applications.

Frame Size II (3WL1216): Breaking capacity is 66/80/100kA, suitable for occasions with higher requirements for breaking capacity.

  1. Mounting Method Selection:

Fixed Type: Small space occupation and low cost, suitable for occasions where frequent maintenance is not required.

Drawout Type: Easy to maintain and replace, suitable for key circuits, but occupies more space.

Model Comparison Table of Siemens 3WL1N16-1600A ETU45B-G-LCD-3P with Other Brands

> 메모: The model “33WL1N16is a typo; the correct model should be 3WL1116 (Frame Size I) or 3WL1216 (Frame Size II) 1600A 3P ETU45B-G-LCD.

  1. Model Clarification and Core Parameters
매개변수 항목Specification ValueDescription
Product SeriesSiemens SENTRON 3WLAir circuit breaker
정격전류1600에이Frame size current is 1600A
Pole Number3PThree-pole
Trip UnitETU45B-G-LCDElectronic trip unit with LSIG protection (Overload L, Short-circuit S, Instantaneous I, Ground fault G) and LCD display
Breaking Capacity3WL1116: 55/66그만큼Different breaking capacities for Frame Size I/II
3WL1216: 80/100그만큼
Mounting MethodFixed/DrawoutOptional
Rated Voltage690뷔와50/60헤르츠
  1. Comparison of Corresponding Models and Parameters of Mainstream Brands
BrandCorresponding ModelFrame Size정격전류Trip Unit TypeProtection FunctionBreaking CapacityMounting MethodRemarks
지멘스3WL1116-3EG45-4GA4I/II1600에이ETU45B-G-LCDLSIG (엘: Long-time delay, S: Short-time delay, I: Instantaneous, G: Ground fault)I: 66그만큼Fixed/DrawoutOriginal model with communication and measurement functions
3WL1216-3EG45-4GA4II: 80그만큼
씨줄Emax2 E2N1600 R1600 PR121/P-LSIG-LCD-3PS21600에이PR121/P-LSIG-LCDLSIG, with energy management and fault recording65그만큼Fixed/DrawoutCompatible with PROFIBUS DP, measurement accuracy class 0.2
슈나이더 일렉트릭Masterpact MTZ2 16H2 Micrologic 5.0A-LCD-3P1600에이1600에이Micrologic 5.0A-LCDLSIG, with energy metering and event recording100그만큼Fixed/DrawoutNew generation MTZ2 series with higher breaking capacity
친트NA1-2000X-1600M/3P LSIG-LCD2000에이1600에이M-type intelligent controller-LCDLSIG, with RS485 communication and harmonic analysis65그만큼Fixed/DrawoutCost-effective domestic alternative with abundant accessories
맛있는CDW3-2000N-1600M/3P LSIG-LCD2000에이1600에이MT-LSIG-LCDLSIG, with fault diagnosis and remote control60그만큼Fixed/DrawoutTechnical cooperation with Schneider Electric, stable performance
Changshu SwitchgearCW1-2000/1600A 3P LSIG-LCD2000에이1600에이Intelligent trip unit-LCDLSIG, with overvoltage/undervoltage protection65그만큼Fixed/DrawoutWell-known domestic brand with high cost performance
  1. Detailed Comparison and Analysis of Key Parameters

3.1 Protection Function Comparison

BrandTrip Unit Model과부하 보호Short-circuit ProtectionGround Fault ProtectionSpecial Functions
지멘스ETU45BI²t/I⁴t selectable, adjustable from 0.4-1InShort-time delay 0.1-0.4s, instantaneous 2-10InAdjustable from 0.2-0.8InCommunication (PROFIBUS/MODBUS), energy data acquisition
씨줄PR121/PInverse time/definite time selectableShort-time delay 0.05-0.5s, instantaneous 2-15InAdjustable from 0.1-0.5InPre-alarm function, fault location, maintenance reminder
슈나이더 일렉트릭Micrologic 5.0AThermal memory function, I²t characteristicShort-time delay 0.05-1s, instantaneous 2-15InAdjustable from 0.1-0.5InPower quality analysis, 100 event records
친트M-typeInverse time characteristic, adjustable from 0.4-1InShort-time delay 0.1-0.4s, instantaneous 2-10InAdjustable from 0.2-0.8InHarmonic monitoring, remote control and parameter setting
맛있는MT-typeInverse time characteristic, adjustable from 0.4-1InShort-time delay 0.1-0.4s, instantaneous 2-10InAdjustable from 0.2-0.8InFault self-diagnosis, historical record inquiry

3.2 Mechanical and Electrical Life Comparison

Brand기계적 수명전기적 수명작동 주파수
지멘스150,000 operations10,000 operations (AC-3)300 operations/hour
씨줄150,000 operations10,000 operations (AC-3)300 operations/hour
슈나이더 일렉트릭150,000 operations10,000 operations (AC-3)300 operations/hour
친트100,000 operations8,000 operations (AC-3)200 operations/hour
맛있는100,000 operations8,000 operations (AC-3)200 operations/hour

3.3 Dimension and Installation Compatibility Comparison

BrandWidth (mm)Height (mm)Depth (mm)Mounting Method호환성
Siemens 3WL1116320434291 (Fixed) / 450 (Drawout)35mm DIN rail / Screw mountingCompatible with 3WA series
ABB Emax2320430285 (Fixed) / 445 (Drawout)Screw mountingCompatible with Emax series
Schneider Electric MTZ2320430290 (Fixed) / 455 (Drawout)Screw mountingCompatible with MT series
Chint NA1320430290 (Fixed) / 450 (Drawout)Screw mountingCompatible with NA1 series
Delixi CDW3320430290 (Fixed) / 450 (Drawout)Screw mountingCompatible with CDW3 series
  1. Alternative Selection Recommendations
  2. Original Replacement: The Siemens 3WL series has been gradually upgraded to the 3WA series (예를 들어, 3WA1116-3EG45-4GA4), which maintains the same installation dimensions and protection functions with higher intelligence.
  3. Brand Replacement Priority:

High-end industrial applications: Priority should be given to ABB Emax2 or Schneider Electric MTZ2, which have better breaking capacity and communication functions.

Buildings and infrastructure: Choose Chint NA1 or Delixi CDW3 for high cost performance and low maintenance costs.

Projects with limited budgets: Choose Changshu Switchgear CW1 for stable performance and affordable price.

  1. Key Selection Notes:

Ensure that the breaking capacity ≥ the maximum short-circuit current of the system (a 20% margin is recommended).

The protection function of the trip unit matches the load type (LSIG is required for motor loads, and LSI is optional for distribution loads).

The installation dimensions match the existing cabinet space to avoid cabinet modification.

The communication protocol is compatible with the monitoring system (PROFIBUS/MODBUS/Ethernet).

  1. 요약

Siemens 3WL1116/3WL1216 1600A ETU45B-G-LCD-3P is a mature and reliable air circuit breaker, and all mainstream brands have alternative models with equivalent performance. During selection, comprehensive consideration should be given to application scenarios, budgets and system requirements to ensure that the protection functions, breaking capacity and installation compatibility meet the needs.

이전:

다음:

답장을 남겨주세요