위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

Schneider Electric MCB A9P52606 - 접촉기,회로 차단기,태양광 인버터,전기 계량기,태양 전지

소식무역 뉴스

Schneider Electric MCB A9P52606

Schneider Electric A9P52606 is a 소형 회로 차단기 (MCB) of the Acti9 iC40 series, featuring 1P+N pole configuration, 6A rated current, and C-type tripping curve. It is designed for overload and short-circuit protection of conventional distribution circuits such as lighting and socket systems, with a rated breaking capacity of 6kA (IEC 60947‑2)/4.5그만큼 (EN 60898). It adopts DIN rail mounting and has an IP20 protection rating.

  1. 모델 해석
ItemDetails
모델A9P52606
SeriesActi9 iC40
TypeMiniature Circuit Breaker (MCB)
극 구성1P+N (1 protective pole, N pole for switching only)
정격전류6에이
Tripping CurveC형
Breaking Capacity6그만큼 (IEC 60947‑2), 4.5그만큼 (EN 60898‑1)
Mounting MethodDIN Rail
Protection RatingIP20
  1. 핵심 기술 매개변수
ParameterStandard
Rated Operational Voltage (Ue)230V AC 50/60HzEN/IEC 60947‑2
정격전류 (In)6에이EN/IEC 60947‑2
Tripping CharacteristicC형 (instantaneous tripping at 5In‑10In)EN/IEC 60898‑1
Ultimate Breaking Capacity (중환자실)6그만큼 (230뷔와)EN/IEC 60947‑2
Service Breaking Capacity (Icn)4.5그만큼 (230뷔와)EN/IEC 60898‑1
Rated Impulse Withstand Voltage (Uimp)4kVEN/IEC 60947‑2
Overvoltage CategoryEN/IEC 60947‑2
오염도3EN/IEC 60947‑2
Operating Temperature-25℃~70℃EN/IEC 60947‑2
전기적 수명20,000 operationsEN/IEC 60947‑2
기계적 수명20,000 operationsEN/IEC 60947‑2
Dimensions (W×D×H)1 기준 치수 (18mm) × 44mm × 91mmSchneider Electric Technical Manual
Neutral Pole PositionLeft SideSchneider Electric Technical Manual
Tripping Unit TypeThermal-magneticSchneider Electric Technical Manual
  1. 기능적 특징
  2. 1P+N Design: Live wire protection plus synchronous neutral wire switching, suitable for single-phase distribution systems, with clear wiring and convenient maintenance.
  3. Type C Tripping Curve: Suitable for conventional loads such as lighting and sockets, balancing overload time-delay and short-circuit instantaneous tripping, with strong resistance to inrush current.
  4. High Breaking Capacity: 6그만큼 (IEC 60947‑2)/4.5그만큼 (EN 60898‑1), capable of handling severe short-circuit faults and ensuring distribution safety.
  5. Standard Mounting: DIN rail mounting with 1-module width, saving switchgear space, and compatible with Acti9 series accessories (예를 들어, 보조 접점, alarm contacts).
  6. 환경 적응성: IP20 protection rating, resistant to temperatures ranging from -25℃ to 70℃, meeting the requirements of industrial and civil distribution environments.
  7. Application Scope

Overload and short-circuit protection for single-phase distribution circuits of lighting, 소켓, small motors, 등., in commercial buildings and industrial plants.

Places with high requirements for power supply reliability, such as office buildings, hotels, and hospitals.

Compatible with Acti9 series distribution boxes, used in scenarios such as terminal power distribution and branch circuit protection.

  1. 선택 권장 사항
  2. 부하 매칭: Type C curve is suitable for non-inductive loads (예를 들어, 조명, 소켓); avoid selecting Type D (for power loads) or Type B (for electronic equipment) curves.
  3. Circuit Matching: With a rated current of 6A, it is suitable for 1.5mm² copper core cables (long-term current-carrying capacity ≥ 10A), and the circuit length should be ≤ 100m.
  4. Breaking Capacity: The 6kA breaking capacity is suitable for terminal distribution; the front-end should be equipped with molded case circuit breakers with higher breaking capacity (예를 들어, 15kA and above).
  5. Accessory Selection: According to monitoring requirements, select accessories such as auxiliary contacts (예를 들어, A9A26924) and alarm contacts (예를 들어, A9A26934).
  6. 문제 해결
결함 현상가능한 원인Troubleshooting Methods
Frequent TrippingOverload, line grounding/short-circuit, mismatched tripping curveCheck load current and insulation resistance; replace MCB with a matching tripping curve
Failure to CloseUnreset tripping mechanism, line short-circuit, contact ablationManually reset the trip lever, locate the short-circuit point, replace damaged contacts
Excessive Temperature RiseLoose wiring, 접촉 산화, high ambient temperatureTighten wiring terminals, 폴란드어 연락처, improve ventilation and heat dissipation
Insufficient Breaking CapacityLack of front-end protection, excessive short-circuit current in the lineUpgrade front-end protection, select MCB with higher breaking capacity
  1. 대체 솔루션

Intra-series Alternatives: A9P52610 (1P+N, 10에이, C형), A9P52616 (1P+N, 16에이, C형), 등., maintaining mounting and accessory compatibility.

Cross-series Alternatives: Schneider Electric IDPN series (예를 들어, A9D18606, 1P+N, 6에이, C형) or ABB S200 series (예를 들어, S201M‑C6, 1P+N, 6에이, C형). It is necessary to verify the matching of mounting dimensions and breaking capacity.

Complete Guide to Other Models of Schneider Electric Acti9 iC40 Series

Schneider Electric Acti9 iC40 series is a miniature circuit breaker (MCB) specially designed for single-phase/three-phase distribution systems. With 1P+N as the core product, it also provides multiple pole configurations including 2P, 3P, 4P, and 3P+N. The tripping curves cover Type B/C/D, and the breaking capacity is divided into standard type (4.5kA Icn/6kA Icu) and Type N (6kA Icn/10kA Icu), with rated current covering the full range of 1A~63A. The following is a structured and complete list of models:

  1. Model Naming Rules (A9PXXXXXX)
PositionCodeMeaning
1-2A9Acti9 Series Identifier
3PExclusive Code for iC40 Series
42-4Breaking Capacity: 2 = Standard Type (4.5kA/6kA), 4 = Type N (6kA/10kA)
56/2/3/4/7극 구성: 6 = 1P+N, 2 = 2P, 3 = 3P, 4 = 4P, 7 = 3P+N
6-701~63정격전류: 01 = 1A, 02 = 2A, 04 = 4A, 06 = 6A, 10 = 10A, 16 = 16A, 20 = 20A, 25 = 25A, 32 = 32A, 40 = 40A, 50 = 50A, 63 = 63A
Curve IdentifierB/C/D: Type B (3In-5In), C형 (5In-10In), D형 (10In-14In)
  1. Classified List of Full Series Models
  2. 1P+N (Most Commonly Used)
    Tripping CurveBreaking Capacity정격전류모델
    Type BStandard Type2A/4A/6A/10A/16A/20A/25A/32A/40AA9P22602/A9P22604/A9P22606/A9P22610/A9P22616/A9P22620/A9P22625/A9P22632/A9P22640
    Type N2A/4A/6A/10A/16A/20A/25A/32A/40AA9P42602/A9P42604/A9P42606/A9P42610/A9P42616/A9P42620/A9P42625/A9P42632/A9P42640
    C형Standard Type2A/4A/6A/10A/16A/20A/25A/32A/40A/50A/63AA9P22602/A9P22604/A9P52606/A9P22610/A9P22616/A9P22620/A9P22625/A9P22632/A9P22640/A9P22650/A9P22663
    Type N2A/4A/6A/10A/16A/20A/25A/32A/40A/50A/63AA9P42602/A9P42604/A9P54606/A9P42610/A9P42616/A9P42620/A9P42625/A9P42632/A9P42640/A9P42650/A9P42663
    D형Standard Type10A/16A/20A/25A/32A/40A/50A/63AA9P62610/A9P62616/A9P62620/A9P62625/A9P62632/A9P62640/A9P62650/A9P62663
    Type N10A/16A/20A/25A/32A/40A/50A/63AA9P64610/A9P64616/A9P64620/A9P64625/A9P64632/A9P64640/A9P64650/A9P64663

    2P (Two-pole)

Tripping CurveBreaking Capacity정격전류모델
C형Standard Type6A/10A/16A/20A/25A/32A/40AA9P52206/A9P52210/A9P52216/A9P52220/A9P52225/A9P52232/A9P52240
Type N6A/10A/16A/20A/25A/32A/40AA9P54206/A9P54210/A9P54216/A9P54220/A9P54225/A9P54232/A9P54240
D형Standard Type16A/20A/32A/40AA9P62216/A9P62220/A9P62232/A9P62240
Type N16A/20A/32A/40AA9P64216/A9P64220/A9P64232/A9P64240
  1. 3P (Three-pole)
Tripping CurveBreaking Capacity정격전류모델
C형Standard Type6A/10A/16A/20A/25A/32A/40AA9P52306/A9P52310/A9P52316/A9P52320/A9P52325/A9P52332/A9P52340
Type N6A/10A/16A/20A/25A/32A/40AA9P54306/A9P54310/A9P54316/A9P54320/A9P54325/A9P54332/A9P54340
D형Standard Type16A/20A/32A/40A/50AA9P62316/A9P62320/A9P62332/A9P62340/A9P62350
Type N16A/20A/32A/40A/50AA9P64316/A9P64320/A9P64332/A9P64340/A9P64350
  1. 4P (Four-pole)
Tripping CurveBreaking Capacity정격전류모델
C형Standard Type6A/10A/16A/20A/32A/40AA9P52406/A9P52410/A9P52416/A9P52420/A9P52432/A9P52440
Type N6A/10A/16A/20A/32A/40AA9P54406/A9P54410/A9P54416/A9P54420/A9P54432/A9P54440
  1. 3P+N (Three-pole + Neutral)
Tripping CurveBreaking Capacity정격전류모델
C형Standard Type16A/20A/32A/40AA9P52716/A9P52720/A9P52732/A9P52740
Type N16A/20A/32A/40AA9P54716/A9P54720/A9P54732/A9P54740
D형Standard Type20A/32A/40AA9P62720/A9P62732/A9P62740
Type N20A/32A/40AA9P64720/A9P64732/A9P64740
  1. Key Features and Selection Points
  2. Core Advantages:

1P+N Design: Live wire protection plus synchronous neutral wire switching, suitable for 230V single-phase systems, saving installation space (1 module = 18mm).

Graded Breaking Capacity: Standard type is suitable for terminal distribution, while Type N is suitable for front-end circuits close to distribution transformers.

Tripping Curve Adaptability: Type B (for electronic equipment), C형 (for lighting/sockets), D형 (for motors/power loads).

  1. Comparison with the Original Model:

The model you queried: A9P52606: 1P+N, 6에이, C형, standard breaking capacity (4.5kA/6kA).

Upgraded Type N version: A9P54606 (breaking capacity upgraded to 6kA/10kA).

Same current with different curves: A9P42606 (Type B), A9P62606 (D형).

  1. Accessory Compatibility: The full series is compatible with Acti9 standard accessories, such as auxiliary contacts (A9A26924) and alarm contacts (A9A26934).
  2. 일반적인 애플리케이션 시나리오
Model Example응용 시나리오
A9P52606 (1P+N, 6에이, C형)Residential/commercial lighting circuits, sockets for small electronic devices
A9P54616 (1P+N, 16에이, C형, Type N)Kitchen appliances, air conditioner sockets (requiring higher breaking capacity)
A9P64232 (2P, 32에이, D형, Type N)Power equipment such as single-phase water pumps and compressors
A9P54340 (3P, 40에이, C형, Type N)Industrial equipment such as three-phase fans and small air compressors

 

이전:

다음:

답장을 남겨주세요