Série ABB M3JP (Xangai) Motores de indução trifásicos à prova de chamas de alta eficiência para áreas perigosas
O ABB M3JP series are low-voltage cast-iron high-performance flameproof three-phase induction motors for hazardous areas manufactured by ABB Shanghai Electric Motors Co., Ltda. Developed on ABB’s global unified design platform with advanced modular ADEPT design, they represent ABB’s flagship flameproof low-voltage motor range.
Designed specifically for explosive gas atmospheres in Zone 1 and Zone 2, these motors feature ultra-high efficiency (IE3 as standard, IE4 available for selected models) and exceptional reliability, widely used in petrochemical, coal, farmacêutico, metallurgical and other industries.
- Model Naming Convention
| Papel | Significado | Exemplo |
| M3JP | Series identification: High-efficiency flameproof three-phase induction motor for hazardous areas | M3JP |
| Frame Size | Center height (milímetros) and frame length | 80MA, 90LA, 100LA, 112MA, 132SM, 160MA, 180LA, 200LA, 225SM, 250M, 280S, 315S, 315M, 355S, 355M |
| Montagem | International standard mounting configurations | M=B3 (foot-mounted) |
| A=B5 (flange-mounted) | ||
| B=B35 (foot + flange-mounted) | ||
| E=B14 (small flange-mounted) | ||
| Poloneses | Número de pólos, determining synchronous speed | 2=2900rpm (50Hz) |
| 4=1450rpm (50Hz) | ||
| 6=970rpm (50Hz) | ||
| 8=730rpm (50Hz) | ||
| Special Options | Special designations | G=Special voltage/frequency |
| L=Low noise | ||
| W=Outdoor type | ||
| TH=Humid tropical type | ||
| CT4=Gas group IIC |
Complete model example: M3JP160MA4-CT4
Descrição: M3JP series, 160mm frame, B5 flange mounting, 4 postes (1450rpm), gas group IIC, temperature class T4 flameproof motor.
- Principais especificações técnicas
| Item | Padrão | Opcional |
| Efficiency Class | IE3 (Alta eficiência) | IE4 (Premium Efficiency) |
| Flameproof Rating | Ex db IIB T4 Gb (padrão) | Ex db IIC T4/T5/T6 Gb |
| Ex db I Mb (for coal mines) | ||
| Ingress Protection | IP55 | IP56 / IP65 (enhanced dust & water protection) |
| Classe de isolamento | Classe F (temperature rise evaluated as Class B) | Class H |
| Método de resfriamento | IC411 (self-ventilated) | IC416 (separately driven fan cooling, suitable for VFD operation) |
| Tensão nominal | 380V / 400V (50Hz) | 220V/380V, 415V, 440V, 660V, etc.. |
| Frequência nominal | 50Hz | 60Hz |
| Faixa de potência | 0.25kW ~ 950kW | Custom power |
| Pole Range | 2P, 4P, 6P, 8P | 10P, 12P (custom) |
| Conexão | Star/Delta (Star ≤3kW, Delta ≥4kW) | Special connection |
| Dimensões de montagem | IEC standard | Custom dimensions |
| Weight Range | Aprox.. 10kg (smallest) ~ 1500kg (largest) | Depending on configuration |
- Flameproof Characteristics & Certificações
4.1 Flameproof Principle
Featuring Ex db flameproof construction, safety is ensured by two protective measures:
Flameproof enclosure (Ex d): Withstands internal explosion pressure and prevents flame propagation to the external hazardous atmosphere.
Surface temperature limitation (Ex b): Maximum surface temperature of all motor parts does not exceed the limit defined by temperature class (T4=135°C, T5=100°C, T6=85°C).
4.2 Applicable Hazardous Environments
| Ambiente | Applicable Zone | Gas Group | Temperature Class |
| Explosive gas atmosphere | Zone 1 (explosive mixture likely under normal operation) | IIB (padrão) | T4 (padrão) |
| Zone 2 (explosive mixture unlikely under normal operation, only in fault conditions) | IIC (opcional, for more hazardous gases including H₂, acetylene) | T5/T6 (opcional) | |
| Underground coal mine | Category I (mining) | EU (methane) | T1–T4 |
4.3 Certificações
Doméstico: CQST (China Quality Supervision and Testing Center for Explosion-Proof Products)
Internacional: IECEx, ATEX, UL, CSA, etc..
Classification Society: ABS, DNV, LR, etc.. (opcional)
- Complete Model List (Grouped by Frame Size)
5.1 Small Frames (80–132mm)
| Frame | Poloneses | Faixa de potência (kW) | Typical Models |
| 80MA | 2,4,6 | 0.25–0.75 | M3JP80MA2 (0.75kW,2P) |
| M3JP80MA4 (0.55kW,4P) | |||
| M3JP80MA6 (0.25kW,6P) | |||
| 90LA | 2,4,6 | 1.1–1,5 | M3JP90LA2 (1.5kW,2P) |
| M3JP90LA4 (1.1kW,4P) | |||
| M3JP90LA6 (0.75kW,6P) | |||
| 100LA | 2,4,6 | 2.2–3.0 | M3JP100LA2 (3.0kW,2P) |
| M3JP100LA4 (2.2kW,4P) | |||
| M3JP100LA6 (1.5kW,6P) | |||
| 112MA | 2,4,6 | 4.0–5.5 | M3JP112MA2 (5.5kW,2P) |
| M3JP112MA4 (4.0kW,4P) | |||
| M3JP112MA6 (3.0kW,6P) | |||
| 132SM | 2,4,6,8 | 5.5–7.5 | M3JP132SM2 (7.5kW,2P) |
| M3JP132SM4 (5.5kW,4P) | |||
| M3JP132SM6 (4.0kW,6P) | |||
| M3JP132SM8 (3.0kW,8P) |
5.2 Medium Frames (160–250mm)
| Frame | Poloneses | Faixa de potência (kW) | Typical Models |
| 160MA | 2,4,6,8 | 11–15 | M3JP160MA2 (15kW,2P) |
| M3JP160MA4 (11kW,4P) | |||
| M3JP160MA6 (7.5kW,6P) | |||
| M3JP160MA8 (5.5kW,8P) | |||
| 180LA | 2,4,6,8 | 18.5–22 | M3JP180LA2 (22kW,2P) |
| M3JP180LA4 (18.5kW,4P) | |||
| M3JP180LA6 (15kW,6P) | |||
| M3JP180LA8 (11kW,8P) | |||
| 200LA | 2,4,6,8 | 30–37 | M3JP200LA2 (37kW,2P) |
| M3JP200LA4 (30kW,4P) | |||
| M3JP200LA6 (18.5kW,6P) | |||
| M3JP200LA8 (15kW,8P) | |||
| 225SM | 2,4,6,8 | 45–55 | M3JP225SM2 (55kW,2P) |
| M3JP225SM4 (45kW,4P) | |||
| M3JP225SM6 (30kW,6P) | |||
| M3JP225SM8 (22kW,8P) | |||
| 250M | 2,4,6,8 | 75–90 | M3JP250M2 (90kW,2P) |
| M3JP250M4 (75kW,4P) | |||
| M3JP250M6 (45kW,6P) | |||
| M3JP250M8 (37kW,8P) |
5.3 Large Frames (280–355mm)
| Frame | Poloneses | Faixa de potência (kW) | Typical Models |
| 280S | 2,4,6,8 | 110–132 | M3JP280S2 (132kW,2P) |
| M3JP280S4 (110kW,4P) | |||
| M3JP280S6 (75kW,6P) | |||
| M3JP280S8 (55kW,8P) | |||
| 315S | 2,4,6,8 | 160–200 | M3JP315S2 (200kW,2P) |
| M3JP315S4 (160kW,4P) | |||
| M3JP315S6 (110kW,6P) | |||
| M3JP315S8 (75kW,8P) | |||
| 315M | 2,4,6,8 | 220–250 | M3JP315M2 (250kW,2P) |
| M3JP315M4 (220kW,4P) | |||
| M3JP315M6 (132kW,6P) | |||
| M3JP315M8 (90kW,8P) | |||
| 355S | 2,4,6,8 | 280–315 | M3JP355S2 (315kW,2P) |
| M3JP355S4 (280kW,4P) | |||
| M3JP355S6 (160kW,6P) | |||
| M3JP355S8 (110kW,8P) | |||
| 355M | 2,4,6,8 | 355–400 | M3JP355M2 (400kW,2P) |
| M3JP355M4 (355kW,4P) | |||
| M3JP355M6 (200kW,6P) | |||
| M3JP355M8 (132kW,8P) |
- Cross-Reference Order Codes with Major Global Brands
Below are equivalent order codes for ABB M3JP series flameproof motors against other leading brands, matched by power, postes, flameproof rating and mounting:
| ABB M3JP Model | Siemens | Schneider | Eaton | Domestic Alternative (Nanyang Explosion Proof) |
| M3JP90LA4-1.1kW | 1LG4090-4AA70-Ex | ATV212HD11N4-Ex | D2N090L4-Ex | YBX3-90L-4-1.1kW |
| M3JP132SM4-5.5kW | 1LG4132-4AA70-Ex | ATV212HD55N4-Ex | D2N132S4-Ex | YBX3-132S-4-5.5kW |
| M3JP160MA4-11kW | 1LG4160-4AA70-Ex | ATV212HD11N4-Ex | D2N160M4-Ex | YBX3-160M-4-11kW |
| M3JP180LA4-18.5kW | 1LG4180-4AA70-Ex | ATV212HD18N4-Ex | D2N180L4-Ex | YBX3-180L-4-18.5kW |
| M3JP200LA4-30kW | 1LG4200-4AA70-Ex | ATV212HD30N4-Ex | D2N200L4-Ex | YBX3-200L-4-30kW |
| M3JP225SM4-45kW | 1LG4225-4AA70-Ex | ATV212HD45N4-Ex | D2N225S4-Ex | YBX3-225S-4-45kW |
| M3JP250M4-75kW | 1LG4250-4AA70-Ex | ATV212HD75N4-Ex | D2N250M4-Ex | YBX3-250M-4-75kW |
| M3JP315S4-160kW | 1LG4315-4AA70-Ex | ATV212HD16N4-Ex | D2N315S4-Ex | YBX3-315S-4-160kW |
- Selection Guidelines & Recomendações de substituição
- Flameproof rating matching: Select according to gas group (IIB/IIC) and temperature class (T4/T5/T6) of the hazardous area. IIC motors can replace IIB, but not vice versa.
- Efficiency selection: IE3 standard for general applications; IE4 premium efficiency for high energy-saving requirements.
- Cooling method: IC416 with separate fan recommended for VFD applications to avoid overheating at low speeds.
- Dimensões de montagem: Strictly comply with IEC standard dimensions to ensure compatibility.
- Requisitos de certificação: Confirm required certifications for critical applications (CQST for domestic projects, IECEx/ATEX for international projects).
- Replacement notes:
Ensure replacement power ≥ original and flameproof rating ≥ original.
Verify mechanical dimensions: shaft height, shaft diameter, keyway size.
Confirm terminal box position and cable entry size match the original motor.
For special environments (marine, outdoor, humid tropical), select correspondingly configured models.
- Ordering & Packaging Information
Official order code: Same as model number, por exemplo, M3JP160MA4, M3JP225SM4-CT4.
Standard packaging: Plywood case, single or multiple units per package.
Origin: ABB Shanghai Electric Motors Co., Ltda. (Endereço: 88 Tianning Road, Minhang District, Xangai)
Lead time: 2–4 weeks for standard models; 4–8 weeks for custom models.
Acessórios: Motor body, terminal box cover, foundation bolts, certificate of conformity, copy of explosion-proof certificate.
Contator,disjuntor,inversor solar,medidor elétrico,baterias solares